HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTF rid
r
BCIS Home I Log In I User Registration I Hot Topics 'I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map links Search
Product Approvalr/�/i ApA (ItFli
R USER: Public User SCANNED
01y
Product Approval Menu > Product or Application Search > Application List > Application Detail St Lude COjanh/
FL # I FL11602-R4
Application Type RECEIV D Revision��
Code Version 2017 �r—` '
Application Statu MAR ��$ Approved �T2U�J qkJ�n,
<—
ST. LUCIE COUNTY BUILDING DIVISTON
REVIEWED FOR C IA
Comments ST. Lucie County Permitting REVIE. D Y
Archived C>) DATE
PLANS AND PERMIT MUST BE KEPT ON JOB
Product Manufacturer InterWrap, Inc. SITE OR NO INSPECTIONS) WILL BE MADE-,
Address/Phone/Email 32923 Mission Way
Mission, NON -US 00000
(551) 574-2939
mtupas@interwrap.com
Authorized Signature I Eduardo Lozano
elozano@interwrap.com
Technical Representative
Eduardo Lozano
Address/Phone/Email
32923 Mission Way
Mission, NON -US 00000
(778)945-2891
elozano@interwrap.com
THESE PLANS AND ALL PROPOSED WORK
Quality Assurance Representative
ARE SUBJECT TO ANY CORRECTIONS
Address/Phone/Emall
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Category
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
ri Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 09/30/2019
Validated By I John W. Knezevich, PE
12l Validation Checklist - Hardcopy Received
Certificate of Independence
FL11602 R4 CO _2017 01 COI Nieminen.aif
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2015
ASTM D226 (physicals)
2009
FRSA/TRI April 2012
2012
CONcEAL.ED FASTENERS OR ATTACHMENTS
TAS 110 (weathering)
2000
ARE THE RESPONSIBILITY OF THE
CONTRACTOR °RRECORD
FILE
COPY
Equivalence of Product Stan(
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/10/2017
10/11/2017
10/15/2017
12/12/2017
I
lF�# ��Idf�
�¢�Gt>< I11i11Y1�r
Q�1��
"i"s'"
d,,.«"Nk'4�.pe., .�fi'tk" .m.%
_
11602.1
Titanium Roof
�Underlayments
Synthetic sheet -type roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No I
FL11602 R4 II 2017 10 FINAL ER INTERWRAP
FL11602-
R4.p—d
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-45
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of a specific underlayment system beneath foam -on the
FL11602 R_AF_2017 10 FINAL ER_INTERWRAP
FL11602-
R4.pd
sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER
Sections 5 and 6 for other Limits of Used.
Created by Independent Third Party: Yes
The State of Florida is an AA/EEO employer.
Under Florida law, email addresses are public
electronic mail to this entity. Instead, contact tl
Section 455.275(1), Florida Statutes, effective 0
they have one. The emalls provided may be use
supply a personal address, please provide the Dep
Back E Next
:: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
:: Privacy Statement :: Accessibility Statement :: Refund Statement
:cords. If you do not want your e-mail address released in response to a public -records request, do not send
office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Dber 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
for official communication with the licensee. However email addresses are public record. If you do not wish to
tment with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click bgEe_.
Product Approval Accepts:
EVALUATION REPORT
Interwrap, Inc.
32923 Mission Way
Mission, BC V2V-6E4 Canada
(551)574-2939
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 111980.11.08-R4
FL11602-R4
Date of Issuance:11/03/2008
Revision 4:10/10/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. I he documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6tb Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Titanium"m Roof Underlayments
LABELING: Labeling shall be in accordance %
herein.
CONTINUED COMPLIANCE: This Evaluation Repor
Quality Assurance documentation changes, of
this Evaluation Report by the named client
changes or the referenced Quality Assurance
Evaluation Report relative to updated Code re
ADVERTISEMENT: The Evaluation Report numb
advertising literature. If any portion of the Ev
INSPECTION: Upon request, a copy of this entir
its distributors and shall be available for inSDE
This Evaluation Report consists of pages 1
Prepared by:
i
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlle
3. Robert Nieminen, P.E. does not have nor will a
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will a
product.
5. This is a building code evaluation. Neither Tri
project on which this Evaluation Report, or pre
specifically for that purpose.
the requirements the Accredited Quality Assurance Agency noted
is valid until such time as the named product(s) changes, the referenced
provisions of the Code that relate to the product change. Acceptance of
:onstitutes agreement to notify Robert Nieminen, P.E. if the product
locumentation changes. Trinity] ERD requires a complete review of this
iuirements with each Code Cycle.
r preceded by the words "Trinity IERD Evaluated" may be displayed in
luation Report is displayed, then it shall be done in its entirety.
Evaluation Report shall be provided to the user by the manufacturer or
.tion at the job site at the request of the Building Official.
ugh 7.
The facsimile seal appearing was authorized by Robert
Nleminen; P.E. on 10/10/2017. This does not serve as an
electronically signed document.
o acquire or will it acquire, a financial interest in any company manufacturing or
by any company manufacturing or distributing products it evaluates.
uire, a financial interest in any company manufacturing or distributing products for
quire, a financial interest in any other entity involved in the approval process of the
[vIERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
ms versions thereof, is/was used for permitting or design guidance unless retained
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underla
Compliance Statement: TitaniumTM'
compliance with the intent of the foll
in accordance with applicable sect
Requirements and Limitations / Condi
2. STANDARDS:
i Underlayments, as produced by Interwrap, Inc., have demonstrated
sections of the 61h Edition (2017) Florida Building Code through testing
the following Standards. Compliance is subject to the Installation
of Use set forth herein.
Section Pro a Standard
Year
1507.1.1, T1507.1.1 Unrolling, Breaking Strength, Pliability ASTIVI D226
2009
1507.1.1 Tear Strength ASTM D1970
2015
1507.1.1, T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970
2015
1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12)
2012
TAS 110 Accelerated Weathering TAS 110
2000
3. REFERENCES:
Knibt Examination Reference
Date
ERD (TST6049) Physical Properties 115010.04.09
04/29/2009
ERD (TST6049) Physical Properties 115010.05.10
05/14/2010
ERD (TST6049) Physical Properties 135520.06.11
06/15/2011
ERD (TST6049) ASTM D226 138010.08.11
08/11/2011
ERD (TST6049) Wind Uplift 135520.08.11-1
08/12/2011
ITS(TST1509) ASTM D226 311801000Q-003
04/26/2007
ITS(TST1509) ASTM D226 3130639COQ-002A
08/21/2007
ITS (TST1509) Physical Properties 3126617COQ-005
10/31/2007
ITS(TST1509) ASTM D226 101823107COQ-011
01/23/2015
PRI (TST5878) ASTM D1970 OCF-341-02-01
09/20/2017
PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02
10/03/2017
PRI (TST5878) ASTM D1970; Tear strength OCF-332-02-02
10/03/2017
PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02
10/03/2017
ITS (QUA1673) Quality Control ITS Listings
Current
ITS (QUA1673) Quality Control Service Confirmation
09/30/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:
4.1.1 TitaniumTM PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a
polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24
Ibs/square. Meets ASTM D1970 as a single -layer and meets FRSA/TRI April 2012 when
used in 2-ply system.
4.2 Mechanically Fastened Underlayments:
4.2.1 Titanium"" UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side
with a polymer coating. Unit weight 2.5 Ibs/square. Meets FBC 1507.1.1(Exception).
4.2.2 TitaniumTM' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core
coated on both sides
with a polymer coating. Unit weight 4.0 Ibs/square. Meets FBC 1507.1.1 (Exception).
4.2.3 TitaniumTM° UDL-50 is a synthetic sheet -type underlayment comprised of a woven core
coated on both sides
with a polymer coating. Unit weight 4.7 Ib's/square. Meets FBC 1507.1.1 (Exception).
Exterior Research and Design, U.C. i Evaluation Report 111980.11.08-R4
Certiftcate ojAuthoriratlon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R4
Titanium Roof Underlayments Revision 4:10/10/2017
Page 2 of 7
5. LIMITATIONS:
5.1
5.2
5.3
5.4
5.5
e ;
T III 7 E .
This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
This Evaluation Report is not fo� use in FBC HVHZ jurisdictions.
Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
Titanium'Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
Allowable Roof Covers:
�'£�Fsb
{
F" p�4a' k�
y'ty" v` '+.<'_
�° p
x�F.tt 'gfwi-�R roMY' t '
5� �i
? i
�')
�' �8 f^
ro�'t#
.s�Fi.�t�oisr,ki&,yltmaa'Yk"'S..<ina.'
s'
�rfj{j��! t�
Na
Asphalt
Wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
& Shingles
Slate
Titanium PSU-30
i' d
g, 31 1 iOR F
fir; s}
���
i
� ���S 11-
3y"�i ak# i
i% �5��
a ',.a�`, `L,. ¢ gya y{
� � ���
��
° slVr,g ,-"V%"'i
tyig
(Silvassa, India)
x r
�
` I'Sees � ij� �t
;
� �
@
���������
��€ �r�
,
r
ql x �??�;
Titanium PSU-30
Yes
2
o
} t 1 J yk W E
a
mat. i NP
" «
w
(Brentwood, NH)
, �u�r-
Titanium UDL-25
a t 5 S
:� E
S'`."g "1 6hg( •� ¢�
T4h ttyx
.:�ixx��a
�i
IgS "_,5-.1'f
Titanium UDL-30
a _ `�w
"}{aasaStnpyi
ie�se*aheeLttt�� pl
��ess�
��Yes ��
�����°
4
Titanium UDL-50
'- jAr;5y„2 Fi3
£+e-.P�
i' Yes
'N
i �
5.5.1 "Foam -On Tile" is limited to Ise of following Approved tile adhesives / underlayment combinations.
t
7ae1A."A Ti,
,
Adhesive
Florida Product Approval
Underlayments
Dow TileBondTM
I FL22525
Titanium PSU-30 (Silvassa, India)
ICP Adhesives Polyset® AH-160
I FL6332
Titanium PSU-30 (Silvassa, India)
5.6 Allowable Substrates: Titanium PSU-30:
5.6.1 Direct -Bond to Deck:
➢ New untreated plywood;
➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond.
5.6.2
➢ ASTM D226, Type I or II felt.
➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted).
1 Refer to Tile Manufacturers orAdhesive
Exterior Research and Design, U.C.
Certificate 4Authorization #9503 6Tu
1
Florida Product Approval for Overturning Moment Resistance Performance.
Evaluation Report 111980.11.08-R4
DN (2017) FBC NON-HVHZ EVALUATION FL11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 3 of 7
T r� Ti E :
5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile ADDlications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
i
systems that are not addressed in FRSA/TRl April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate pass ng pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer Ito FRSA/TRl April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for
determination of design wind loads.
#1 Maximum Design Pressure = -45 asf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTY D41
Underlayment: One or two plies, Titanium PSU-30 (Silvassa, India), self -adhered
#2 Maximum Design Pressure = -30 Dsf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annularlring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps
Spacing: 6-inch o.c. at flinch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#3 Maximum Design Pressure = 430 Dsf*:
Deck: Min. 15/32-1 ch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction. I
Base Sheet: Titanium UDL j30 (printed side up)
Fasteners: 12 ga. annuls ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at (flinch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
#4 Maximum Design Pressure =I-45 Dsf*:
#5
Deck: Min. 15/32-1rch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 6a.,1-5/8" diameter tin caps
Spacing: 6-inch o.c. ai14-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
Deck: Min. 15/32=inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDiL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter an'd length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered
Exterior Research and Design, U.C. I Evaluation Report 111980.11.08-R4
Certificate ofAuthori:oUon #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R4
Titanium Roof Underlayments Revision 4:10/10/2017
Page 4 of 7
5.6.3.1
5.7
5.8
For mechanically attached Bas
or exceed that required under
�i
'TI�iN11Y �,��a
Sheet, the maximum design pressure for the selected assembly shall meet
ISA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed y a qualified design professional to resist the elevated pressure criteria.
Commonly used methods a �e ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
Exposure Limitations:
Titanium UDL-25, Titanium LID'L-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days.
Titanium PSU-30 (Silvossa, lndi j shall not be left exposed for longer than 90-days.
Titanium PSU-30 (Brentwood, NH) shall not be left exposed for longer than 30-days.
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
�!A {s� n F
-may
e T ?c�" 4 w� ��_"a
r', x 4 i ,r
DEC�iillri.STLU"I'►Oi�iS
<.``#'''aa",.4arodliEt?.�iM`7�ad,NITA1YQi�IS,FVRI`1i1E'f.`i
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max.10-tile stack 5:12
Titanium PSU-30 (Silvossa, India)
I Lugged
Max. 10-tile stack 6:12
6. INSTALLATION:
6.1 Titanium Roof Underlayments shall be installed in accordance with Interwrap published installation
requirements subject to the Li I Wtations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3.1 Shall be installed in complia11ce with the requirements for ASTM D226, Type I or II underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet -
width for double -layer applications.
6.3.2 Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch
diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or
plastic cap staples.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches.
Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with
the surface markings on the exposed face of the underlayment. When batten systems are to be installed
atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the
battens.
Exterior Research and Design, I.I.C. I Evaluation Report 111980.11.08-R4
Certiilcate o/Authorhatlon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 5 of 7
6.3.4
I I
I TRINITY ER. ;
Double layer application; begin' by fastening a 25-inch wide strip along the eaves. Place a full -width sheet
over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining
minimum 25-inch side (horizontal) laps, resulting in a double -layer application.
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanicallv Fastened Roof Cover:
6.4.3
Cut manageable sections and ie-roll with the release film side out.
Membrane Application:
➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in
place, printed side up.
➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the
membrane into place.
➢ Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner.
➢ End (vertical) laps shall be�minimum 12-inches and side (horizontal) laps shall be minimum 3-inches.
➢ If the membrane becomes misaligned, cut the roll and re -start.
➢. Upon completion, inspect Ithe membrane and repair any defects or fish -mouths.
The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact
Interwrap for approved sealant or mastic types.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above asla guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Interwrap published requirements for tile staging. Interwrap specifies
minimum 24-hour cure time after installation, before loading of roofing tiles.
The use of sealant or mastic at the fastener penetrations is required for all tile roofing installations. Contact
Interwrap for approved sealant or mastic types.
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-30 (Silvassa, India), self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3
followed by Titanium PSU-30 (Sllvassa, India) in accordance with Section 6.4.
6.5.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above has a guideline.
For mechanically fastened tile roofing, refer to Interwrap published installation instructions, but not less
than the fastener density from FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile roofing, refer to Section 5.6.3 herein.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 2 herein, and Interwrap published requirements for tile staging. Interwrap specifies
minimum 24-hour cure time after installation, before loading of roofing tiles.
The use of sealant or mastic at the fastener penetrations is required for all tile roofing installations. Contact
Interwrap for approved sealant or mastic types.
Exterior Research and Design, I.I.C. I Evaluation Report 111980.11.08-R4
Certiftcate ofAuthoriration k9503 i EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R4
Titanium Roof Underlayments Revision 4:10/10/2017
Page 6 of 7
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or
this product.
8. MANUFACTURING PLANTS:
Contact the noted CIA agency for it
The following plants have qualified p
f
F *`
r1__"':1_111_`01"__"1"-�'
t9
TI1N1`fY
Having Jurisdiction in order to properly evaluate the installation of
:)n on product locations covered for F.A.C. 61G20-3 CIA requirements.
under their respective physical properties specifications.
��fYrt+� W`i' f 4 s},
t fr ✓n, £ d �
A"Nr.�.,
]err f45s1 i d R } `�.
• `s ��iN 3�ra�"i'CA .:. i }j+�},
Mission, BC, Canada
FBC 1507.1.1(Exception)
Titanium UDL-30; Titanium UDL-50
Qingdao, China
FBC 1507.1.1(Exception)
Titanium UDL-25; Titanium UDL-30; Titanium UDL-50
Silvassa, India
FRSA/TRI 04-12 (2-ply system)
Titanium PSU-30 (Silvassa, India)
Brentwood, NH
ASTM D1970 I
Titanium PSU-30 (Brentwood, NH)
9. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc. —
Exterior Research and Design, LLC.
Certificate o/RuthoN:ation #9503 6T"
(604) 520-3321
END OF EVALUATION REPORT -
Evaluation Report 111980.11.08-R4
ON (2017) FBC NON-HVHZ EVALUATION FL11602-114
Titanium Roof Underlayments Revision 4:10/10/2017
Page 7 of 7