HomeMy WebLinkAboutDOMESTIC TANK- l �
CONTAINERS
Containing Our World's Energy"
F-
0
c�
U)
w
x
w
M
OUTSIDE
>
LL-
0
DIAMETER
0
a
0
O
LEG
WIDTH
General Specifications
Conforms to the latest edition of the ASME code for
Pressure Vessels, Section VIII, Division 1. Complies
NFPA 58.
Rated at 250 psig from -20" F. to 1250 F. All tanks mad/ be
evacuated to a full (14.7 psi) vacuum.
Vessel Finish: Coated with epoxy red powder. ( Tanks coated
with the epoxy powder must be buried). For Aboveground use,
tanks may be coated with TGIC powder.
Applicable federal, state or local regulations may co tain
specific requirements for protective coatings and cathodic
protection. The purchaser and installer are responsible for
compliance with all federal, state or local regulations.
OVERALL LENGTH
DOME
LEG SPACING
- - WITHDRAWAL
VALVE
NOTICE`\
FLOAT L.P. GAS ANODE
GAUGE CONNECTION
O
FILLER
VALVE
f O
SERVICE / NAME
MULTIVALVE PLATE
RELIEF
VALVE
FITTINGS LAYOUT UNDER DOME
AGUG VESSEL
All vessels dimensions are approximate
DIMENSIONAL INFORMATION
WATER
OUTSIDE
HEAD
OVERALL I
OVERALL
LEG
LEG
WEIGHT
QUANTITY
FULL
PER
CAPACITY
DIAMETER
TYPE
LENGTH I
HEIGHT
WIDTH
SPACING
LOAD
STACK
120 wg.
24"
Ellip
5'- 5 13/1611
3' - 0"
10 1/8"
3' - 0"
245 lbs.
96
12
454.2 L
609.6 mm
1671.3mm
911.4 mm
257.2 mm
914.4 mm
111.1 kg.
250 wg.
31.5"
Hemi
7'- 2 1/2"
3' - 7 1/2"
12 3/4"
3' - 6"
472 lbs.
63
9
946.3 L
800.1 mm
2197.1 mm .
1104.9 mm
323.9 mm
1066.8 mm
214.1 kg.
320 wg.
31.5"
Hemi
8' -11 3/4"1
3' - 7 1/2"
12 3/4"
4' - 0 1/4"
588 lbs.
45
9
1211.2 L
800.1 mm
2736.9 mm
1104.9 mm
323.9 mm
1225.6 mm
266.7 kg.
500 Wg.
37.42"
Hemi
9' -10"
4' -1 7/16"
15"
5' - 0"
871 lbs.
30
6
1892.5 L
950.5 mm
2997.2 mml
1255.7 mm
381.0 mm
1524.0 mm
395.1 kg
1000 wg.
40.96"
Hemi
15' -10 13/16"
4' - 4 5/16"
16 1/4"
9' - 0"
1729 lbs.
15
5
3785.0 L
1040.4 mm
4846.6 mmi
1344.6 mm
412.8 mm
2743.2 mm
784.3 kg
Rev: Jan. 27, 2016
STORAGE TANK IS ADEQUATELY
ANCHORED TO PREVENT FLOATATION,
COLLAPSE OR LATERAL MOVEMENT
DURING THE BASE FLOOD EVENT.
ALL WORK SHALL BE IN ACCORDANCE WITH
NFPA 54-58, NATIONAL FUEL GAS CODE
AND FLORIDA FUEL GAS CODE 2017.
TANKS INSTALLED IN TRAFFIC AREAS
SHALL BE PROTECTED WITH GALV. STEEL
SCHED. 80 PIPE BOLLARDS (4) 6- LONG
X 3' BURY DEPTH WITH CAP 0 3' O.C.
SIDE ELEVATION
GRASS
9LB. ANODE BAG
MAX BUOYANCY = p.*g*VtwA
= 1.94 slug/W * 32.2 ft/s= * 16.04 W
= 1002 CBS
NET BUOYANCY = MAX BUOYANCY — WEIGHT OF EMPTY TANK
= 1002 ILBS — 245 LEIS
= 757 LEIS
FORCE ON r CABLE = 757 / 2 = 379 LEIS
TENSILE STRENGTH OF r CABLE = 2000 LBS
FORCE ON AUGER ANCHOR = 379 / 2 = 190 LEIS
MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LEIS
r 7x19 GALV.
AIRCRAFT CABLE
2 TOTAL (IN POLY.
SLEEVE)
AUGER ANCHOR, 480
LONG W/ 6.0 HELIX
4 TOTAL
, - 1 11-1- -
i TAN , (MAX COVER) h
I I
EXCAVATION SIZE:
6'L x 3'W x SD
r 7xl9 GALV.
AIRCRAFT CABLE
STRAPPING BOLT
�-- AUGER ANCHOR, 487
LONG W/ 6.0 HELIX
I
SCALE1/4' = 1'-0'
Ferrellgas
3232 SE Dixie Hwy.
Stuart, FL 34997
z
O
14
L7
O
N
r--4
O
z
U
H
a
DRAWN:
APPROVED:
DRAWING
NUMBER
T.1-
LP120
58-94
GAS CODE
Table 15.1(o)
Polyethylene Plastic Pipe Sizing Between
Birst-Stage and Second -Stage
Regula#ors: Nominal Outside Diameter UPS)
Gas:
Undiltited Propanie
I
let Pressure:
16.0 psi
P�ressure
Drop:
1.0 psi
Specific.Gr&ity:
1.52
Plastic
Pipe
1/2.in.
4/4 in.
1 in.
11/4.in.
11/2 in.
2 im
Length
A
SDR 9.33
(0.660)
SDR 11.0
(0.860)
SDR 11.00
(1.077)
SDR 10.00
(1.328)
SDR11.00
(1.554)
SDR 11.00
(1.943)
30
2143
4292
7744
13.416
20260
36402
40
1835
3673
6628
11482
17340
91155
50
1626
3256
.5874
10176
15368
27612.
60
1473
2950
5322
9220
13924
25019
70
1355
2714
4896
8483'
12810
23017
80
1261
2525
4555
7891
119,18,
21413
90
1183
2369
4274
7404
11182
'20091
100
1117
2238
4037
6994
10562
18978
125
990
1983
8578
6199
9361
16820
150
897
1797
3242
5616
8482
15240
175
826
1653
2983
5167
7803
14020
200
778
1539
2775
4807
7269
18048
225
721
1443
2603
4510
6811
12238
250
681
1363
2459
4260
6434
11560
275
646
1294
2336
4646
6111
10979
300
611
1235
2228
3860
5830
10474
350
567
1136
2050
3551
5363
9636
400
528
1057
1907
3304
4989
8965
450
495
992
1789
MOO
4681
811
500
468
937
1690
2928
4422
7945
600
424
849
1531
2653
4007
7190
700
390
781
1409
2441
3686
6623
800
363
726
1311
2271
3429
6161
900
340
682
1290
2191
3217
5781
j 1000
322
644
1162
2012
3039
5461
1500
258
517
933
1616
2441
4385
• 9000
'
221
443
798
1383
I
2089
3759
IPS• Iron pipe
size.
I
SDR: Standard dimension
ratio.
Notes:
(1) Capacities
are in 1000
Btu/hr.
(2) Dimensions in parentheses are inside diameter.
r
I
2011 Edition
I
I
I
ti
w
"M'Y�
m
d
o
g
a1
0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 0 C. 0 0 o o o a o o o 0 0 0 0 0 0 0
000o$. o -o 00 �a., rn w a,o of o '�qu wn ->• mww n mo 'C' o
o m a m W- t� 0 ct ct 0 N t' m .. t� a� 0 n a .C{ o o+.t` �? W at o, oa to -
wlN N ti W ti.:+ rwi ;. Q1 Oi oo t: �D . tC �i te) v� -.r ''P w +r ai ai oq ai Oq ai ei N CVci N N- Pj Cl.
a;w;c;�aoim.I u�il � .$ani l oN-�cm Ln
' n c0�vw4rnml �r �l g ani_ocnyl c..
O O O. ' O ci I O 'mO O ,: O O O O Ov� o O O O O O C O O.: O. O O m m
O a1 A r•t a1 'O n .ti a,ry [O O O w m n W .O •A op ar in .-i t� w N of 1n .r 1� eta '.r of
W w rn .- •c : ul q .i r ul m ra o t -n w q a1 ci .., t o ct o as M m w W m n t� Z' 'Of ;o 8 W
oriu;1,'v. v'onm00,06 cvNCC7— -' .r-.. ..I-�i, ", -
�
n
pp
O t0. .Oy. .
N W1 GV co
r � O-. Q
h'oq O01
o0i�'. On pO� �'.
L V�
p+� n
.0c. .a.
O?A W
.1D !; m rWr �D
0�1.
.4V
e�
C, W
i�rr�D t0
U�D h�q In
kom V'r
o
C
oM
°-
-D
,apn &Wn .ya
oV-*y Ca $n paf
r oW�
coV. . w
o O
LO v
ai
wum�
Noi
Vma�
r-i
.9
r to n P
�O N O+ o
a'0
N fn a1 i,Nyy' Yr
N N H
N n %n t0
H
az�1. c� COj.. ti .�i
o O. S. Q�1 007
- - - r r
n tr
ti
N
vim'
gn
PI
.O. .�i .�+ r••�
rY r•1 rti .-� n
.-� .+ rti
co
cpooco W,n n
o
N ul i11
.N
� �
p� C>Ot�
O
n O, al W.M
OI CA W � h
Otf� ea��.-�Om
t` f0 b �t1
tom. 1q MNO
to to u1 u1
map y�. �y 0,
�
Im co
d
�0 W N Cq
G�V .r•+
.�+,.Nr rNi
u1
w W w
:a1..M an
!q
s
b
b
oonc�
o wrn�
vt`wm.'+
is eo Cn �n
��pp� ��yV
'V Maanila�l
a�jmNNN
u�
WNCIPIi�t
o� Q.�
p�
V
OYNC
'O1�n
.b
x
o0000
000Lno
pow o'oo
0o00
oi'
oZo
00CCo0o
000nal
00000'omoNinno
0
m
Vo,
n0o
tom m
m Ol Oapp
ul
�
.-i r.
.-i ri .i r•i. n
r-i N..
�