Loading...
HomeMy WebLinkAboutPLANS EXAMINER REVIEWSGANNED I ! St tueie ftrit F6 ran^ 1+ 4:t-- l 8 d 3— d (03 q PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc 4/9/2018 , ( REVISIONS MADE 5-25-2018 ) 4/9/2018 Comment:1) POOL IS IN A FLOOD ZONE, PLEASE NOTE PER SECTION (R322.3.6) OF THE FBCR REQUIRES -THE CONSTRUCTION DOCUMENTS SHALL INCLUDE DOCUMENTATION ... THAT THE DESIGN AND METHODS OF CONSTRUCTION TO BE USED MEET THE APPLICABLE CRITERIA OF THIS SECTION. I FLOOD -RESISTANT CONSTRUCTION. ( NOTED ON BOTTOM RIGHT OF PAGE 1 POOL PLAN) 4/9/2018 Comment: 2) MECHANICAL EQUIPMENTISERVICING THE POOL SHOULD BE ELEVATED ABOVE THE BFE. EQUIPMENT SHALL BE LOCATED AT OR ABOVE THE ELEVATION REQUIRED IN SECTION R322.2 OR R322.3. (R322.1.6) ( NOTED ON BOTTOM RIGHT OF PAGE 1 POOL PLAN 1 4/9/2018 Comment: 3) PLEASE PROVIDE PRODUCT DATA FOR CHILD BARRIER. (' INCLUDED CHILD BARRIER DATA SHEET) 4/9/2018 Comment: 4) PLEASE SHOW ON DRAWINGS THE REQUIRED BONDED PARTS PER (E4204.2) (;ADDED RIGHT SIDE PAGE 3 POOL PLAN) 4/9/2018 Comment: 5) PLEASE SHOW ON DRAWINGS THE BONDING OF THE POOL WATER. (E4204.3) 1 ADDED CENTER OF PAGE 2 POOL PLAN) 4/9/2018 Comment: 6) PLEASE PROVIDE SOIL DESIGN PARAMETERS- SOIL BEARING CAPACITY &COMPACTION REQUIREMENTS. (R401.2) RI 4/9/2018 Comment: 7) PLEASE PROVIDE DETAIL AT WATERFALL DROP. ([A] 107.2.1) ( ADDED CENTER OF PAGE 2 POOL PLAN ) 4/9/2018 Comment: 8) PLEASE PROVIDE A SOIL BORING TEST & REPORT TO DETERMINE THE SOIL'S CHARACTERISTICS. THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN APPROVED METHOD. (R401.4) ( INCLUDED SOIL REPORT & ENGINEERS LETTER) 4/9/2018 Comment: 9) PLEASE ENLARGE ELECTRICAL DETAIL TO BE LEGIBLE. ([A] 107.2.1) ( ENLARGED ON RIGHT SIDE OF PAGE 3 POOL PLAN) ( SUBMIT PLUMBING SUB-APP SIGNED BOTH LOCATIONS AND NOTARIZED ) i ( SUBMIT UPDATED ELECTRICAL SUB-APP SIGNED AND NOTARIZED) ItEC% EIV also MAY 2 9 2018 C-2)e.0-M OF IZGv15SD Qua'vs Permitting Department St. Lucie County, FL J5--2`9 -/f