Loading...
HomeMy WebLinkAboutEVALUATION REPORT0 �`��N���y EXTERIOR RESEARCH 9c DESIGN, LLC. C� p� Certificate of Authorization #95o3 ` �y ! 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 KI ERD PHONE: (203) 262-9245 EVALUATION REPORT FAX: (203) 262-9243 ! Polyglass USA, Inc. Evaluation Report P12060.02.09-11115 150 Lyon Drive I FL5259-R20 Fernley, NV 98408 Date of Issuance: 02/24/2009 Revision 15: 08/25/2014 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and'the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the Florida Building Code, 2010 sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number precededby the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation] Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. I This Evaluation Report consists of pages 1 through 11. Prepared by: Robertl.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 G' ?.= 'T The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/25/2014 This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: I. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Flle TRINITY.: ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced, by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, Physical Properties, ASTM D226 2006 1507.8.3, 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3,1507.5.3 Physical Properties ASTM D2970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: kuiLty Examination Reference Date FM Approvals (TST 1867) PRI (TST 5878) Wind Uplift I 3004091 /12/2000 PRI (TST 5878) Physical Properties Physical Properties I PRIO1111 0OS4//1208/200 PRI (TST 5878) Physical Properties PUSA-005-02-01 PUSA-013-02-01 /2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 12/23/2002 PRI (TST 5878) PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties I Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 PUSA-033-02-01 0707 /13/2005 PRI (TST 5878) PRI (TST 5878) Physical Properties I PUSA-035-02-01 012/200 929/2006 PRI (TST 5878) Physical Properties Physical Properties PUSA-055-02-02 PRI (TST 5878) Physical Properties PUSA-061-02-02 PUSA-076-02-01 O2////110/200/2007 PRI (TST 5878) PRI (TST 5878) Physical Properties I PUSA-083-02-01 02/22/2008 04/14/2008 MTI (TST 2508) Ph sicaI Pro erties Y P Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties p 1X20H7A RX14E8A 04/01/2008 ERD T (TST 6049 ( ) Physical Properties 11752.09.99-1 01/29/2009 ERD (TST 6049) ERD (TST 6049) Wind Uplift 11757.08.01-1 02/08/2000 08/13/2001 ERD (TST 6049) Wind Uplift Physical Properties 11776.06.02 01/16/2003 ERD (TST 6049) Wind U lift p 02200.07.03 01/14/2003 ERD (TST 6049) PhysicalP1740.01.07 Properties P5110.04.07-1 0/04/2007 ERD (TST 6049) Wind Uplift P9260.03.08 04/11/2007 ERD (TST 6049) Physical Properties P13450.08.09 03/21/2008 ERD(TST 6049) n Wind Uplift P30540.11.09-R1 08/23/2009 ERD (TST 6049) ERD (TST 6049) Physical Properties P31030.11.09-1 11/30/2009 11/30/2009 ERD (TST 6049) Wind Uplift Physical Properties P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-3 P33360.06.10 11/30/2009 ERD (TST 6049) Physical Properties P33370.03.11 06/25/2010 ERD (TST 6049) ERD (TST 6049) Physical Properties P33370.04.11 03/02/2011 04/26/2011 ERD (TST 6049) Physical Pro erties y p Physical Properties P37300.10.11 10/19/2011 ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390,08.12-2 C41420.09.12-3 08/07/2012 09/11/2012 Exterior Research and Design, I.I.C. certificate of Authorizarion #9503 Evaluation Report P12060.02,09-1115 FL5259-R20 Revision 15: 08/25/2014 Page 2 of 11 S. i ERD Enti Examination Reference Date ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-Ri 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-Ri 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 ERD (TST 6049) Physical Properties P443605C 05/15/2014 ERD (TST 6049) Physical Properties P46520.08.14 08/22/2014 ]CC-ES(EVL2396) 09/01/2012 IBC Compliance ESR-1697 09/01/2012 Miami -Dade (CER 1592) HVHZ Compliance NOA 12-0713.02 Polyglass USA 02/1 Manufacturing Affidavit Products Current 02/18/20/200909 Polyglass USA P/LAffidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, L-C. (QUA9625) Quality Control Service Confirmation, R14571, 2QA Exp. 08/08/2015 UL, LLC. (QUA9625) Quality Control Service Confirmation, MTS PLUS Exp. 07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavments• 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Underlavments• 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly -film surface; meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. i 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.S Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/mz polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual Pro- is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile Pro— is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and for Bonded Underlavments 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVH2. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Certificate of Authorization #95o3 Evaluation Report P32060.02.09-1115 FL5259-R20 Revision 15: 08/25/2014 Page 3 of 11 { TRINITY: ERD 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: TABU jT;-_, oP Gov t nvifpnis ': ; - Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Slate Shingles Elastobase Yes Yes No Yes' Yes Elastobase P Yes Yes No Yes Yes Yes Yes Polystick MTS I Yes Yes No Yes Yes Yes I Polystick MTS PLUS I Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes See 5.4.1 No Yes Yes Poystick TU Plus Yes Yes Yes See 5.4.1 Yes Yes Yes Polystick TU Max I No Yes Yes Ves Dual Pro See 5.4.1 No No Yes Yes No Yes Yes Yes Tile Pro j Yes Yes Yes i See 5.4.1 Yes Yes Yes I IElastoflex S6 G Yes Yes Yes NO See 5.4.1 Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes See 5.4.1 N° Yes Yes Polyflex G FR Yes Yes No No Yes Poiyflex SAP or SAP FR Yes Yes Yes Yes See 5.4.1 No Yes Yes Mule -Hide SA-APP Cap Sheet or SA- Yes APP Cap Sheet (FR) Yes Yes Yes No Yes See 5.4.1 5.4.1 "Foam -On Tile" is limited to use of the following Approved the adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ✓ 3M- 2-Component Roof Tile Adhesive AH-160 (formerly POWOOm PolyPro AH160): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro. ✓ 3M'" Foam Roof Tile Adhesive RTA-1: Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro ✓ Dow TileBond: Polystick TU P, Polystick TU, Plus, Polyflex SAP or Tile Pro ✓ Convenience Products' Touch 'n Seal Storm Bond Roof Tile Adhesive: Polystick TU Plus, Polystick TU Max 5.5 Allowable substrates are noted below: Exterior Research and Design, I.I.C. Certificare ofAathoriz°tion ay9503 Evaluation Report P32060.02.09.R35 FL5259-R20 Revision 15: 08/25/2014 Page 4 of 11 TRINITY ERE 5.5.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSS; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polygloss does not require priming of new or existing plywood or OSB sheathing. New or existing plywood orOS8 sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: i > ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.5.2 Bond -to -Insulation: Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C3289, Type ll, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex S6 G or S6 G FR in hot asphalt to: > Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or G FR torch -applied to: > ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.3 Bond to Mechanically Attached Base Laver: Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self - adhered to: > ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex 56 G or S6 G FR in hot asphalt to: > ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Polyflex G or G FR torch -applied to: > Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, refer to Section 5.5.4 herein and FRSA/TRI 07320/8-05 or RAS 120. 5.5.4 Wind Resistance for Underla ment Systems inIFoam-On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.4.1 Maximum Design Pressure = -90 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment; Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-R1s FL5259-R20 Revision 15: 08/25/2014 Page 5 of 11 I I �l 5.5.4.2 Maximum Design Pressure = -135 osf. NI Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 5.5.4.3 Maximum Design Pressure = -315 nsf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 5.5.4.4 Maximum Design Pressure = -622 5 osf. i Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.5 Maximum Design Pressure = -30 0 psf. Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase or Mule -Hide Nail Base (poly -film top surface) mechanically attached with 11 ga. x 1.25-inch long x f- inch head diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. ' Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. i 5.5.4.6 Maximum Design Pressure = -37 5 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase or Mule -Hide Nail Base (poky-fllm top surface) mechanically attached with 11 ga. x 1.25-inch long x f- inch head diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. ' Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 5.5.4.7 Maximum Design Pressure = -37 5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: One (1) or two (2) layers ASTM D226, Type II felt mechanically attached with 11 ga, x 1.25-inch long x 1-inch head diameter round metal cap nails spaced 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. 5.5.4.8 Maximum Design Pressure - -45 osf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: One (1) layer ASTM D226, Type II felt mechanically attached with 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/?-inch diameter tin caps spaced 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex 56 G, applied in full mopping of hot asphalt. 5.5.4.9 Maximum Design Pressure = -45 osf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Two (2) layers ASTM D226, Type II felt mechanically attached with 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.5.4.10 Maximum Design Pressure = -45 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with Simplex MAXX Cap Fasteners spaced 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Exterior Research and Design, I.I.C. Certificate of Authorization #95o3 Evaluation Report P12060.02.09-1115 FL5259-R20 Revision 15: 08/25/2014 Page 6 of 11 TRINITY 5.5.4.11 Maximum Design Pressure = -52.5 osf. ' Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface' for torch -applied cap) mechanically attached with Simplex MAXX Cap Fasteners spaced 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered; center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.12 Maximum Design Pressure = -52 5 osf. Deck: Min. 1S/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase or Mule -Hide Nail Base (poly -film top surface) mechanically attached with Simplex Original Cap Nails spaced 6-inch o.c, at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 5.5.4.13 Maximum Design Pressure = -52 5 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with Simplex Original Cap Nails spaced 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.14 Maximum Design Pressure - 60 osf, Deck: Min.19/32-inch I p ywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap 'or poly -film surface for torch -applied cap) mechanically attached'with 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1- 5/8-inch diameter tin caps spaced 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.15 Maximum Design Pressure - 60 osf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates spaced 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Eiastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.16 Maximum Design Pressure = -90 osf. Deck: Min. 15/32-inch plywood to meet projectrequirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot,- asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with Simplex MAXX Cap Fasteners spaced 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.17 Maximum Design Pressure - 90 osf. Deck: Min. 15/32-inch plywood to meet project" requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates spaced'6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping ofi'hot asphalt or Polyflex G, torch -applied. 5.5.4.18 Maximum Design Pressure - 90 osf, Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface) mechanically attached with Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates spaced 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. 5.5.4.19 Maximum Design Pressure - 97 5 osf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. -film top surface) mechanically attached with 11 ga. x 1.25-inch x 3/8-inch Base Layer: Elastobase or Mule -Hide Nail Base (poly head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: POlystick TU P. Polystick TU Plus, Polyflex SAP, PolyFlex SAP FIR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FIR), self -adhered. Exterior Research and Design, LLC. Certificate of Authorizorion #9503 Evaluation Report P12060.02.09-R35 FL5259-R20 Revision 15: 08/25/2014 Page 7 of 11 • I i TRINITY: ERD 5.5.4.20 Maximum Design Pressure .= -105 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hqt-asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with Simplex MAXX Cap Fasteners spaced 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced stagger center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.21 Maximum Design Pressure = -112 5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction, of AHJ. Base Layer: Elastobase or Mule -Hide Nail Base (poly -film top surface) mechanically attached with 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 6-inch o.c. at the 4-inch wide side laps and 6-inch C.C. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. S.S.4.22 Maximum Design Pressure = -120 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) mechanically attached with OMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates spaced 6-inch D.C. at the 4-inch wide side laps and 6-inch o.c, at five (5) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 5.5.4.23 Maximum Design Pressure = -120 osf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Elastobase (sanded top surface) mechanically attached with Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates spaced 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. 5.5.4.24 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of-45 psf. 5.6 Exposure Limitations: S.6.1 Elastobase, Elastobase P or Polystick MTS PLUS shall not be left exposed for longer than 30-days after installation. 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 90-days after installation. 5.6.3 Polystick MTS, TU P or TU Plus shall not be left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.S Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G), in which case the maximum exposure is 180 days. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2021" for limitations for self -adhering underlayments used beneath tile roof systems. System System One: Mechanically Fastened Tile, Unsealed or Sealed Underlayment System `::' 5:;" iT11'BL'EZ: 7'11:E%S.yS7ElIJl Of?7'IQhTS PF.F2FRSA-M, Underlay Section 1 3.02A Batten only 2 3.026 4 3.02D 5 3.02E 6 1 3.02F Exterior Research and Design, LLC. Certific0te of Authorizotion #9503 Reference Product(s) Modified Cap Sheet Elastoflex S6 G or Elastoflex S6 G FR; Polyflex G or G FR No. 30 / Modified Cap Sheet Base Layer: Elastobase; Elastobase P No. 30 Top Layer: Elastoflex 56 G or Elastoflex 56 G FR; POlyflex G or G FR Elastobase; Elastobase P Self -Adhered Underlayment Polystick MTS; MTS PLUS; TU P; TU Plus; TU Max, Polyflex SAP or SAP FR; Mule - Hide SA-APP Cap Sheet or SA-APP Cap Sheet No. 30 /Self -Adhered Underlayment (FR); Dual Pro; Tile Pro Base Layer: ASTM 0226. Type 11; Elastobase; Elastobase P; Mule -Hide Nail Base Top Layer; Polystick MT5; MTS PLUS; TU P; TU Plus; TU Max; Poiyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro Evaluation Report P32060.02.09-R1S FLS259-R20 Revision IS; 08/2S/2014 Page 8 of 11 -. TRINITY; ERD 1 3.02A Batten only Modified Cap Sheet Elastoflex 56 G or Elastoflex 56 G FR; Polyflex G or G FR System T__o; 2 3.0213 No. 30 / Monirien Cap Sheet Base Layer: Elastobase; Elastobase P Mechanically Fastened Tap Layer: Elastoflex S6 G or Elastoflex 56 G FR; Polyflex G or G FR Tile, Sealed 4 Underlayment System 3.020 Self -Adhered Underlayment Polystick TU P; TU Plus; TU Max; PolyflexSAP or SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR};Dual Pro; Tile Pro 5 3A2E No. 30 / Self -Adhered Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Mule -Hide Nail Base Underlayment Top Layer: Polystick TU P; TU Plus; TU Max, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FRI Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex 56 G or Polyflex G System Four "q'•: 2 3.028 No. 30 /Modified Cap Sheet Base Layer: Elastobase; Elastobase P Adhesive -Set Tile, Top Layer: Elartoflex 56 G or Polyflex G Unsealed or Sealed 4 3.02D Self -Adhered Underlayment Polystick TU P; TU Plus, TU Max; Polyflex SAP or SAP FR; Tile Pro: Mule -Hide SA. Underlayment System APP Cap Sheet or SA-APP Cap Sheet (FR) 5 3.02E No. 30 / Self -Adhered I Base Layer: ASTM D226, Type II; Elastobase; Elastobase P; Mule -Hide Nail Base Underlayment Top Layer: Polystick TU P; TU Plus; TU Max; Polyflex SAP or SAP Fit; Tile Pro; Mule -Hide SA-APP Cap Sheet or SA-,APP Cap Sheet (FR) 1 3.02A No. 30 / Modified Cap Sheet Base Layer: ASTM 0226, Type II; Elastobase; Elastobase P 5ygem Four W: Top Layer: Elastoflex S6 G or Polyflex G Adhesive -Set Tile, 3 3.02C Self -Adhered Underlayment Polystick TU P; TU Plus; TU Max; Polynex SAP or SAP FR; Tile Pro; Mule -Hide SA. Sealed Underlayment System APP Cap Sheet or SA-APP Cap Sheet (FR) 4 3.02D No. 30 / Self -Adhered ease Layer: ASTM D226, Type II; Elastobase; Elastobase P; Mule -Hide Nail Base Underlayment Top Layer: Polystick TU P; TU Plus; TU Max; PolYfex SAP or SAP FR; Tile Pro; Mule -Hide , APP Cap Sheet or SA-APP Cap Sheet (FRI 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase Elastobase P or Mule -Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex 56 G or 56 G FR in hot asphalt or Polyflex G or G FR, torch applied. 6.3.3 For use in the applications, reference is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, Table 2 herein and Section 5.5.4 herein. 6.4 pnhrat;'& nnry _' . __ __ APP Cap Sheet IFr u [vtax rol lex SAP or SAP FR MUle-Hide SA-APp Ca Sheet or SA- R) Dual Pro or Tile pro 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area Para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed Exterior Research and Design, I.I.C. Certifrcote cfAuthorizotion X95o3 Evaluation Report P32060.02.09-R1S FL5259-R20 Revision 15: 08/25/2014 Page 9 of 11 6.4.2.2 6.4.2.3 6.4.2.4 6.4.2.5 6.4.2.6 6.4.3 6.4.3.1 6.4.3.2 6.4.3.3 6.4.4 6.4.4.1 6.4.4.2 6.5 6.5.1 All seal -lap seams (selvage laps) must be rolled with a minimum 28 lb. hand roll ensure full contact and adhesion. For Dw and Tile Pro, align the edge of the top she the end of the glue pattern (the sheet will o� the fabric). N'_'jTR1N1TY vvejap seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the applicaition of the lap. Polystick TU Plus, Dual Pro and Tile Pro may no or exposed roof to wall details Repair of Polystick membranes is to be accom Cement, Polyglass Polyplus 50 Premium MB Fla Tile Underlayment Flashing Cement, Mule -Hid, Wet/Dry Elastomeric Flashing Cement, or Mule• in need of repair, followed by a minimum 6 x 61 Place over the repair area. Patch laps, if needed Ileys, shing Plus iium area - I .­­it,a water shedding manner. 'din All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes use of a stiff broom with a for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of approximately 40-lbs of load applied the roof that are not accessible to a large roller or broom. For tile applications (not o/lowed for Polystick IR-Xe): Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, Table 2 herein and Section 5.5.4 herein, using the instructions noted above as a guideline. For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. For nail -on tile systems over Polystick MTS PLUS: Y Battens are required for loading/staging of lugged file regardless of slope. ➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. Two (2) Ply Underlayment Systems: Polystick MTS or MT5 PLUS followed by Polystick MTS, IIU P, TU Plus, TU Max, TilePro or Polgflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS PLUS followed by Polystick TU P, TU Plus; TU Max, TilePro or PolYflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated iwith the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Elastoflex S6 G or S6 Elastoflex S6 G or S6 G FR shall be installed in compliance; with Current Polyglass published installation requirements. For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual. Fourth Edition, and Table 2 herein. i Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report P12060,02.09-R15 FL5259-R20 Revision 15: 08/25/2014 Page 10 of 11 8. a PJNI-rY:ERD 6.5.2 Elastoflex S6 G or S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or G FR: 6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3- inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for tile staging, : 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI 07320/8-05 must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading/ staging of the tile. 6.7.4 For nail -on tile systems over Polystick MTS PLUS: ➢ Battens are required for loading/staging of lugged tile regardless of slope. ➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. 6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty- eight (48) hours. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Certificate of Authorization #9503 Evaluation Report P12060.02.09-R15 FL5259-R20 Revision 1S: 08/25/2014 Page 11 of 11