HomeMy WebLinkAboutBOAT LIFT SPECIFICATION SHEETMIN. SETBACK REQ.- FRONT SIDES CNR SIDES REAR ZNG. TECH. 4 PILING BOAT LIFT SPECIFICATION SHEET SIZE DWG. NO. REV A ENGINEERING SCALE: AS NOTED I SHEET 1 OF 1 5 NOTE: LOAD SHOULD BE EVENLY DISTRIBUTED BY POSITIONING THE CENTER OF GRAVITY DIRECTLY IN THE CENTER OF HE LIFTING BEAMS AS SHOWN IN THE ILLUSTRZATION ABOVE. 'ourPilingliRs Bow to Stern: ..'Pat (OuitsidoTo_Outside) To Statboar _(11 i3 rToCente 1 000 Ib• 12 ft 6 in loft 7,0W Ib. 12 ft 6 in 12 ft 61n 10,000 Ib. 12 ft 6 in 12 ft 6 in 13,000 Ib. 12 ft 6 in 12 ft 6 Tn 16,600 Ib. 12 ft 6 in 14 it 2016 TOP BEA1N (A) TOP BEAM CRADLE BEAM (B) BUNKS (C) CABLE SIZE (0 ) LEND S,W018. 6" CHANNEL 116. 4' X G' X 1D 8° ALUM 5/16- SS 7/19 (313') 7A00 L6. 6"CHANNEL 1216. 4"X6"X12'6" 8"AUM 5/16' SS 7/16(313") 10A LB.- 7-CHANNEL 12'6" 5"X8"X12'6' B"AUM 5/16"SS 7/16(.313') 13.01I0 7 CHANNEL 12' 6' 5" X 8' X 1T 6" 8' AUM 5/16" SS 7/16 (-M') 16A W L6. B" CHANNEL 12' 6" 6" X 10" X 14' 10" AUM 5/16' SS 7/16 (313') PH:800-325-1116 i�.J FAX:252-747-4377 .` TIDETAMER.cOM DRAWN P.O. BOX 1118 1R(AT MAIM PE[1611L'I<5 SNOW HILL, NC 28580 CHECKED OTHERWISE SPECIFIED: ENG APPR. PROPRIETARY AND CONFIDENTIAL DIMENSIONS ARE IN INCHES DIMENSIONS COMMENTS: THE INFORMATION CONTAINED IN THIS TOLERANCES: DRAWING IS THE SOLE PROPERTY OF FRACTIONAL± TIDE TAMER INDUSTRIES. ANY ANGULAR: MACH± BEND ± REPRODUCTION IN PART OR AS A WHOLE TWO PLACE DECIMAL ± WITHOUT THE WRITTEN PERMISSION OF THREE PLACE DECIMAL ± TIDE TAMER INDUSTRIES IS PROHIBITED. •ta DO NOT SCALE DRAWING 4 3 c- - MOUNTING OPTIONS: TOP MOUNT SIDE MOUNT za (A) 2X 1 /7' SS LAG BOLT MOUNTHARDWARE 3 m 7' MIN. LENGTH (B) 2X 1 /2" SS HEX NUT PILING 5/8'DETERMINED BY CONTRACTOR 2X 1/z' X 2 SS HEX BOLT W/ r LOCKS AND NUTS 10 w W N OZQ�w( I(A)J o00 °0 occim ZLLV CABLE ARRANGEMENT OPTIONS:=ol <�=Ir BULL SINGLE PULL I DOUBLE 4- �0 IL MLIJ) Oa 7 h CAt3LE • DRIVE(E) H.P. MOTQR DRIVESHAFT MINIMUM Ply CONFIGUATION (F) (SIZE & QTY. SINGLE PULL DIRER DRIVE 3/4 H.P. (CITY. 2) 1-1/2- (SCH 40) 8' (QTY. 4) 220V 4.9A EACH SINGLE PULL DIRER DRIVE 1 H.P. (CITY. 2) 1-1/2' (SCH 40) 8' (CITY. 4) 220V SAA EACH DOUBLE PULL DIRER DRIVE 3/4 H.P. (CITY. 2) 1-1/2' (SCH 40) 8' (CITY. 4) 220V 49A EACH DOUBLE PULL DIRECT DRIVE 1"1-1/2' (SCH 40) 8' (QTY-4). 220V 6.8A EACH DOUBLE PULL DIRECT DRIVE 1 H.P. (CITY. 2) 1-1A' (SCH 40) 10' (QTY. 4) 220V 6.8A EACH ENGINEERS SEAL PAULCH INC. NAME I DATE MECH ELECT -CIVIL ENG. 190A BILTMORE ST AiiA ACC 1 5-15-15 PORT SAINT LUCIE, FL 349U PAUL WELCH P.E FLA REG NO.2994i