Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOF` - SCANNED &V Professional'gt BCIS Home } Log In i user Registration 1 7earch } Submit Surcharge Stats & Facts j Publications i FBC Staff BCIS Site Map i Links 1 Search f Florida r `�i s�,4 Product Approval RECEIVED �aglrn q W/�' USER: Public User 8 �fr.;oaRgcnm Product Approval Menu > Product or ApplicatioApplication List > Application Detail MAR 2 6 2018 FL # - ST. Lucie County, Permitting Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Sunlast Metal Address/Phone/Email 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 flvalidation@yahoo.com Authorized Signature I Terry Kapron flvalidation@yahoo.com Technical Representative Sal Delfino Address/Phone/Email 102 Northpoint Parkway Acworth, FL 30102 (954)931-1392 sdelfino@petersenmail.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) I Standard Year TAS-100 1995 TAS-125 2003 Equivalence of Product Standards Certified By ID affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONo ON/A Product Approval Method ` Method 1 Option A Date Submitted Date Validated Date Pending FBC Approval Date Approved 01/25/2018 01/25/2018 01/26/2018 FL # Model, Number or Name Description 18712.1 5-V-Crimip (.032" min.) .032" (min.) Aluminum over 1/2" (min.) Plywood Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes I FL18712 R1 C CAC 15-0212.07.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-176.0 Lrier Installation Instructions Other: The use of a Class "A" fire is not required FL18712 R1 II 15-0212.07.0f outside the HVHZ unless otherwise specified in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: I Evaluation Reports Created by Independent Third Party: 18712.2 PAC-150 (.032" min.) .032" (min.) Aluminum over 1/2" (min.) Plywood Limits of Use I Certification Agency Certificate Approved for use in HVHZ: Yes FL18712 R1 C CAC 15-0212.06.1)df Approved for use outside HVHZ: es Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-166.75 Installation Instructions Other: The use of a Class "A" fire barrier is not required FL18712 R1 II 15-0212.06.odf outside the HVHZ unless otherwise specified in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: I Evaluation Reports Created by Independent Third Party: 18712.3 PAC-150 (24 ga, min.) 24 Ga. (min.) Steel over 1/2" (min.) Plywood Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes I FL18712 Rl C CAC 15-0212.05.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-136.75 I Installation Instructions Other: The use of a Class "A" fire barrier is not required FL18712 RI II 15-0212.05.odf outside the HVHZ unless otherwise specs ied in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 18712.4 I Snap -Clad (.032min.) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.75 Other: The use of a Class "A" fire barrier is not required outside the HVHZ unless otherwise specified in the building code. I .032" (min.) Aluminum over 1/2" (min.) Plywood Certification Agency Certificate FL18712 Rl C CAC 15-0212.04.odf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL18712 RI II 15-0212.04.odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 18712.5 Tite-Loc Plus (.032j' min.) .032" (min.) Aluminum over 5/8" (min.) Plywood Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL18712 R1 C CAC 15-0212.01.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-174.25 Installation Instructions Other: The use of a Class "A" fire barrier is not required FL18712 R1 II 15-0212.0l.pdf outside the HVHZ unless otherwise specified in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: I Evaluation Reports Created by Independent Third Party: 118712.6 Tite-Loc Plus (24 ga. min.) 24 Ga. (min.) Steel over Steel Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL18712 R1 C CAC 15-0212.02.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-196.75 Installation Instructions Other: The use of a Class "A" fire barrier is not required FL18712 R1 II 15-0212.02.1)df outside the HVHZ unless otherwise specified in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: I Evaluation Reports Created by Independent Third Party: 18712.7 Tite-LoclPlus (24 ga. min.) 24 Ga. (min.) Steel over 5/8" (min.) Plywood Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL18712 R1 C CAC 15-0212.03.Ddf Approved for use outside HVHk: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 04/30/2020 Design Pressure: +N/A/-204.25 Installation Instructions Other: The use of a Class "A" fire barrier is not required FLIS712 R1 II 15-0212.03.Ddf outside the HVHZ unless otherwise specified in the building Verified By: Miami -Dade BCCO - CER code. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact)Us :: 2601 Blair Stone Road, Tallahassee Fl, 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employed. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 0 ® eCFeck M Credit Card Safe MIAMI-DADS MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mlamidade.eov/economy Sunlast Metal, Inc. 2120 SW Poma Drive Palm City, FL, 34990 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used *in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration (In Miami Dade County) and/or the AHJ (in area, or material tested for quality assurance purposes manufacturer will incur the expense of such test of such product or material within their juris determined by Miami -Dade County Product Cor of the applicable building code. This product is approved as described herein, including the High Velocity Hurricane Zone of tl DESCRIPTION: 5-V-Crimp .032" Aluminum LABELING: Each unit shall bear a permanent statement: "Miami -Dade County Product Control date stated below. The Miami -Dade County Product Control Section other than Miami Dade County) reserve the right to have this product If this product or material fails to perform in the accepted manner, the ng and the AHJ may immediately revoke, modify, or suspend the use iction. RER reserves the right to revoke this acceptance, if it is .rol Section that this product or material fails to meet the requirements id has been designed to comply with the Florida Building Code Florida Building Code. over %11(min) plywood with the manufacturer's name or logo, city, state and following )ved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA. will occur after t}�e expiration date or if there has been a revision or change in the materials, use, acid/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and remov4of NOA. ADVERTISEMENT: The NOA number preceded Iby the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I INSPECTION: A copy of this entire NOA shall bei provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 5. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No.: 15-0212.07 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 1 of 5 ROOFING SYSTEM APPROVAL: Category: Roofing Sub -Category: Metal, Pan Material: Aluminum Deck Type: Wood Maximum Design Pressure: -176 psf MADE NAMES OF PRODUCTS Product Dimensions .032" Aluminum L = varies' 5-V-Crimp Metal W = 20.5"-24" Roof Panel H ='/2" Min. Thickness 0.01 Min Yield Strength: 23 Fasteners # 10 HWH of sufficiei length to penetrate throe sheathing a minimum of Trim Pieces L = varies W = varies Min. Thickness 0.032" i EVIDENCE SUBMITTED: Test Agency Architectural Testing, Inc. Valspar -Structural) 'ACTURED OR LABELED BY APPLICANT: Test . Product Specifications Description I TAS 110 .032" (min.) Aluminum preformed metal panels, painted or unpainted. TAS 110 TAS 110 D9330.01-450-18 D9330.03-450-18 433 iX515 433B173 Stainless steel screw with capped hex head bonded washer. Standard flashing and trim pieces. Manufactured for each panel width. Test Name/Report Date TAS 100 10/13/14 TAS 125 10/13/14 ASTM B 117 11/21/11 ASTM D 4587, ASTM G 23 11/21/11 NOA No.: 15-0212.07 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 2 of 5 'A APPROVED ASSEMBLIES: System A: 0.032" Aluminum 5-V-Crimp Metal Roof Panel — HORIZONTAL LAPS ARE PERMITTED Deck Type: Wood, Non-insulateld Deck Description: New Construction 1 /32" or greater plywood or wood plank, or for re -roofing 15/32" or greater plywood. Maximum Uplift See Table A below. Pressure: Deck Attachment: In accordance with pplicable Building Code, but in no case shall it be less than 8d ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attac ent method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side - lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. lire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with PAC Contractors Association's current published installation instructions. Metal Panels and Install the ".032" Alumil um 5-V-Crimp Metal Roof Panels" and accessories in compliance Accessories: with PAC Contractors Association's current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panels shall be fastened with corrosion resistant #10 HWH screws of sufficient length to penetrate through the sheathing a minimum of 3/16". Fasteners shall be installed parallel to the roof slope along the pane;'s overlapping ribs (fastening of the center rib is optional) at a maximum spacing as listedlin Table A below. I TABLE A MAXIMUM DESIGN PRESSURES ' Field Perimeter and Corner' Maximum Design Pressure -74.75 psf -176 psf Maximum Fastener Spacing 16" o.c. 8" o.c. 1. Extrapolation shall not be allowed NOA No.:15-0212.07 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 3 of 5 LD41TATIONS 1. Fire classification is not part of this =6 ratings of this product. I refer to a current Approved Roofing Materials Directory for fire 2. The maximum designed pressure listed erein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nr extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panel shall be roll formed in continuousllengths from eave to ridge. Maximum lengths shall be described in the Roofing Application Standard RAS 133. HORIZONTAL LAPS ARE PERMITTED 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility,' and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control) Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or iVodel. 5. All products listed herein shall have a qualify assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative) Code. 6. Panels may be shop or jobsite roll formed with machine model #10120107, 8560904, or RF6631 from PAC Contractors Association. NOA No.: 15-0212.07 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 4 of 5 f � i STIFFENING R PANEL MA Steal &Ali MIN. PANEL THIC 24ga & .032" At PANEL -20.53 to 24.0° G PANEL RIB t 3/I3" N PANEL FASTENERB: t10 Hex Heae rA'rad Scmus ,k,'Almther Saallr q 141»sheas PROFILE DRAWINGS �S AND/OR STRIATIONS ARE OPTIONAL r a yam• � �.i ew.B - LY.Y v mcr c n Ribs & Pane! Striations are OptianW Fa mardbubu puipmes, f isk ricm in ihu centur lib aru uptlulirl I PAC CONTRACTORS I THIS ACCEPTANCE NOA No.: 15-0212.07 Expiration Date: 04/30/20 Approval Date: 04/30/15 Page 5 of 5