HomeMy WebLinkAboutSTANDARD WINDOW ERECTION DETAILSRY
V�� PANEL �l
3) TEK SCREWS WALL PANEL ATTACHED TOOJAMB n rn
('CLASSIC WALL' SHOWN) BUILDING GIRT PROVIDED IN (-CLASSIC WALL" SHOWN) (ADJUST AS REQUIRED) m
A® 7'-6' ELEV. HARDWARE KIT) 7'-6'
B DOOR HEADER I II �� GI� BUILDING GIRT
FACTO INSTALLED • a
ON DOD
CUP -FACTORY A SELF-DRIWNG SCREWS GFIAP�IN�FRMIE b
ATTACHED TO JAMB
(ADJUST AS REQ'D) • HEADER
•
•
DOOR JAMB
CLEAR ON DOORINSTALLED B
OPENING
SIM.
LDDDR7
C z C SUBJAMB, FACTORY
y w INSTALLED ON DOOR—j
0
CLEAR
OPENING
NL
U
/
z
_ L)
U Ci
t IR1 /4'
HE6ADERO ELEV. • •
B
JAMB /
ERECTION NOTES: / m
1) STAND FRAME & ADJUST H z
DOOR FRAME INSTALLATION AT TOP
11
CUP a JAMB AS REQ D.
2) ATTACH CUP TO GIRT W/
o
STAND FRAME &ADJUST CUP AT JAMB AS REQUIRED.
c
(3) SELF-DRIWNG SCREWS WINDOW IS FACTORY
ATTACHED TO FRAME
JAMB (e' SM.) (4) SELF—DRIWNG
WINDOW FRAME INSTALLATION AT TOP
Ri•EWSARD(ARE DEKITED
WINDOW TRIM ELEVATION
IN
STANDARD WINDOW
°
wpCD
ZCO-N
JAMB (8' STANDARD)
O
O C-4 .—
I N
CUP - FACTORY
ATTACHED TO JAMB
ERECTION DETAILS
cn m
N QO I
FINISH
„
FLOOR
(ADJUST AS REQ'D.)
NOTES:
SCREWS
s
r
= �
DOOR TRIM ELEVATION
1) USE ONLY WHERE STANDARD NUCOR
(4) SELF-DRIWNG
1.
o C-)
o I3
z t 2
() ' /
WINDOWS ARE REQUIRED. SEE
COVERSHEET SHEET C1 FOR STANDARD
( )
CUP - FACTORY
ATTACHED TO JAMB
N O M
�,(
WA L K D 0 0 R
EXPANSION BOLTS
WINDOW REQUIREMENTS.
(ADJUST AS REQUIRED)
r
CZ
o Ln -Do
CD)NUCOR
.ERECTION) DETAILS
(PROVIDED IN
HARDWARE KIT)
2) STAND FRAME & ADJUST CLIP AT JAMB
• •
(2) 1/2' EXPANSION BOLTS
=
$
o
Q z x
a
DOOR FRAME INSTALLATION AT BASE
AS REQUIRED. ATTACH CUP TO GIRT WITH
,
p � O
00 USE ONLY WHERE STANDARD NUCOR DOORS ARE
(3) SELF-DRILUNG SCREWS.
O°
STAND FRAME &ADJUST CLIP AT JAMB AS REQ'D.
REQUIRED. SEE COVERSHEET (SHEET C1) -FOR
ATTACH CLIP TO GIRT W/ (3) SELF -DRILLING SCREWS.
r
;
o
STANDARD DOOR REQUIREMENTS.
o
0
o
<
WINDOW FRAME INSTALLATION AT BASE
N
LINER PANEL
(IF REO'D.)
J
INSULATION LINER HEAD COVER
(BY OTHERS) AT 8 GIRTS
CAP TRIM MK. JTDO1
AT 'REVERSE CLASSIC'
PANEL (REO'D. AT
8' OR 10" _ _ _ 8' SUB -JAMB
INSULATION H7040
(BY OTHERS)
AT 24' O.C.
+
Z
_
3070 DOOR MK. HTB01
GIRT AT 7'-6' A.F.F. 6070 DOOR MK. HTBO2
LINER ONLY)
GIRT (BELOW
7'-6' ELEV.)
EXTERIOR
WALL PANEL_ —
AT 10' GIRTS
307Q DOOR MK. HTC01
LINER (IF REQ'D.) CAP TRIM MK. HTD05
AT AT ACCENT AND
—
_
LINER PANEL
CONTINUOUS I (IF REQ'D.)
x
EXTERIOR 6070 DOOR MK. HTCO2
WALL PANEL I
__
- -- --'CLASSIC' PANEL
_
rk WINDOW FRAME
BE HOF CAULK
I
�
W
—❑HER CAP TRIM
(REQ'D. AT LINER ONLY)
CUP MK. JCT01 1
Ht040ul
0
--
----- I— - - MK. HTDOS
(REQ'D. AT LINER ONLY)
JTBO1 AT 8' GIRTS
JTC01 AT 10' GIRLS JAMB COVER
(4) TEK 3
SCREWS H1020
HEAD TRIM AT 12' O.C.
PROVIDED WITH
may= I
7'=2' AF.F.
(REQ'D. AT LINER ONLY)
L — —
WIINN,DDOM
Z
H1040 FA END
SUBJAMB DOOR JAMB
8' FRAME HTDOS
Ee
0
J
HEAD TRIM CAP TRIM MK. HTDOS AT
DOOR
GIRT TO SUBJAMB DETAIL
�
(REQ'D. AT (REO'D. AT
Q
v
�
m U
MK. HTA01 AT 3070 DOOR ACCENT' AND 'CLASSIC'
USE (•) t/z ` T t/z' A307 BOLTS H03OO/NUIS HOOD
WINDOW FRAME LINER ONLY LINER ONLY)
)
w
w
MK. HTA02 AT 6070 DOOR PANEL JTD01 AT
'REVERSE CLASSIC'
FIELD cur GIRT TO LOWTH AS REQUIRED.
6 5 8' AT 8" GIRTS
= a
g W a
DOOR JAMB PANEL (AT LINER ONLY)
JAMB TRIM MK. JTA01
FIELD WORK HOLES IN GIRT TO ACCEPT CLIP AS REOURED
B 5 8' AT 10" GIRTS
r
LLJ
�, H
o
INSULATION AT ACCENT' AND
Y Go`
H1040
AT 12' O.C.
ODOR JAMB COVER MK. JTB01 AT 8' GIRTS
MK. JTC01 AT 10" GIRTS
(BY OTHERS) "CLASSIC' WALL PANEL
HEAD DETAIL
U
JOB NUMBER:
f
• (REO'D. AT LINER ONLY)
JAMB TRIM MK. JM01
,�
SECTION A
S4J0346A
C (5) H1040
WALL AT "REVERSE CLASSIC'
HM05 LINER PANEL
(REO'D. AT (IF REQ'D.)
EQUALLY SPACED
WALLPANEL
0 0 LINER ONLY)
8 5 B' 0 10" GIRTS
SHEET NO.
HEAD TRIM DETAIL — SECTION B
JAMB TRIM DETAIL — SECTION•,C
6 s e' 0 8' GIRTS
D11 of 13
HTA_ & JT_ TRIMS ARE FACTORY CUT TO LENGTH.
HT & JT_ TRIMS ARE FACTORY CUT TO LENGTH.
WINDOW FRAME
JT_
8' OR 10° GIRT
BEND
FIELDITOR
'�
N (REQ'D. AT 8" FRAME
(REQ'D. AT
LINER ONLY) HM05
(BELOW 7'-6' ELEV.)
AND
,l
LINER ONLY)
(REQ'D. AT
8' SUB -JAMB
JAMB
co to INSULATION
H1040
LINER ONLY)
WA—
AT 24" D.C. (BY OTHERS)
DOOR JAMB
r- CUP MK. JCT01
PROVIDSILL ED WITH
WINDOW SYSTEM AT 2440' O.C. AT 12 O.C.
I WITH (4) TEK 3
DOOR
SCREWS (H1020)
WINDOW
8' FRAME
I
P AINS ONlr oL
FRAME
LINER PANEL
BYY NUCOR BUILDING SYSIEIGS, TERIALS DESIGNED AND mTO
—FIELD
MA
WEATH
EXTERIOR INSULATION (IF REQ'D.)
(BY OTHERS
�p�wN U µD ORE METAL
DOOR
JAMB TRIM
PROVIDED WITH EXTERIOR
W�� PA,
BUILDING wHlfDi THEY REPRESENT
ARE THE PRODUCT OF NUCOR
GIRT TO SUBJAMB DETAIL 1
11
JT
WINDOW SYSTEM WALL PANEL
PROTESsl..O ENGINEER WHOSE
USE (4) 1/2"X 1 1/2' A307 BOLTS H05OO/NUTS H0400
JAMB DETAIL
SILL DETAIL
SEAL APPEARS ON THESE DRAWINGS
IS EMPLOYED BY NUCOR BUILDING
SYSTEMS AND DONS NOT SEINE AS
FIELD CUT GIRT TO LENGTH AS REQUIRED.
TRIM CORNER DETAIL
PROJECT
FIELD WORK HOLES IN GIRT TO ACCEPT CUP AS REQUIRED. 1
TOP RIGHT CORNER SHOWN
SECTION B
SECTION CNOT
ENGINOR EER ROECaO AND HALL
BE CONSTRUED AS -SUCH,
L -