Loading...
HomeMy WebLinkAboutPRODUCT REPORTsGANNED 2160 SW Poma Drive By Palm City, FL 34990 I Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications I RECEIVED MAR 2 A .. G-9 ST. Lucie County, Permit , i Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) I Fastener 2 (Method 2,3, & 4 Attachment)- #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC,Sec. Chart 1507.1.1 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Slope: Shall be in compliance with FBC Sec. 1507. REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO See Fastener "�'i����c����a�vves• Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c.. 22" o.c. 22" o.c. 12" o.c. FASTENER SIZE I ' #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, lki TST ID#: 15 7 UL 580-06 & 1897-041 Test Report DS893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/19/15 TAS 125-03 Test Report - D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2:1 ..t 1111.._- ��•`�' D ►'O ''•• Locke Bowden, P.E. does not have, not will acquire a financial int 41h aq �cq r1%M�ia1 under this evaluation. ' Locke BSowden, P.E. is not owned, operated or c trolled by atly coiAparkorriiiidiaturer, or' report-rur N44 f ,'r 160,3 — 0 �T� _ ST. LUCIE COUNTY BUILDING DIVI ON �1-j% STrI l t REVgut f . r REVr`,�{••.FCG'f?10�,. �F: DATPLAKEPS,NAL �.•+'•' SITE OR NO INSPECTION(S) WILL' MADE it::'�►►►�� or distributing products roducts under this FASTENERS OR ATTACHMENTS RESPONSIBILITY OF THE TRACTOR OR RECORD /li 7 ILE COPY FL17022.1 Crimp (26GA Steel), 24" Wide W Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. iouc or greaser riywooa, or Wood plank I 247 1� I 318" opnoniaL srwAnoras Panel Profile Nominal 12" Nominal 12" O.G. O.C. Fasten f9 X 1-1/2" Min. or #10 X 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15132" or greater Plywood, or -Wood plank