Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTShttps:/Iwww.foridabuilding.org/or/pr_app d tl,aspx?param=wGEVX.., FCOft10q0&PAP7T,16p11'' OF BCIS Fibme, I togjn.. I User Reg"tion. HbtTopfcs. I I Submit Surcharge 1 StatS�&Facts NNED Prodtict'Approvail USER: PUblitUser db r4 fit FA "tations FBC Staff. I acrS sitamap I units. I search. Product Approval Menlr> Product or Application Search > Applcation Llst > Application Detail -tl IS- 6 Application Type 12101K Code Version Application Status Comments Archived Product Mappfa,C, uke TO-B IURI; Maitq ia(s Group, 41,c r X6dres/Rh6ne/Eirnaih Rutherfor&,, MUM —7 (ErOO--Y516 1-495: ;,david:r-ulz@tribulltmg.c-Gm Authorized Signature David Ruiz david.rulz@tribulltmg;com T icaj-Representative Address/Ohiane/-Email "EastlRdthefford, INS 07073 '(201) 842-2449 da.,Y.fd'.'r'u izO, tri bu il trhaf4llallsgirbupl' ddiff Quality Assurance Representative Address/Phone/Email Category Rbo. Roofing' Subcategory ndeha�y'ments Compliance Method I Evaluation Report from 6 Florida Registered Architect or a Licensed Plorida'Prdfesslohzil'Engiheer -Evaluation' Report - Hardcopy Received Florida Engineer or Architect Narqe who developed Robert Nieminen the Evaluation Report f3orjda,jjcense pE759156 .Quality Assuranca-Entity U L"LLC .Quality AS;� Cbntract...Fx.O.t.rabon "Date )07/,18/2020 Validated By John W.'Knezevich, PE Certificate of Independence Ref,er,enced,Stan,dar,d,.kp,d,.:YeK,.'(of., Skafvdafd), 11 Validation.Checklist:- Hardoopy Received' FL16046 R6 COI 2017 01 COI Nleminen.pdf AST-M 019716- AS-WK-G1;55 - FM 4474 -FRSA/TRI-Aprjl-2012-;(04-12,) UL 1897 X MM. 2-CA5- 2005 2011 201'2 2012 '1. of-2 3/17/2018, 7:39 A-M Florida Building Code Online f https://www.floridaliuilding,org/pr/pi_app_dtl;aspx?param=wGEVX... Equivalence of Product Standards CeOied.8y Sections -from the. Code. Product -Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL PA' Limits. of Use Approved'for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Desigrti Pressurfm +N/A/-150. �fiis�e 1.yThe design..pressure noted`h of foamromtile systems overtop, the self- Underlayment for one particular applicati ,5:6A for details: 2.)'Refer to ER Section Method 1 Option D 0.9/25/2017 10/OIJ2017 10/0312017 12/12/2017 Name I Descriptiow Installation Instructions FL16048 R6 II 2017 09 FINAL ER TRI- BUILT UNDERLAYMENTS FL16048-R6.pdf Verified By: Robert Nieminen PE-59166 Created'by Tndepenclenf ffiird'15arty: Yes eimpertains to vise Evaluations.Reports Jhering FL16048 R6 AE 2017 09 FINAL ER TRI- i. See ER Section BUILT UNDERLAYMENTS FL16048-R6.pdf for.other Limits of Created-by'.1 dependentThlyd'Party. Yes E k Na-t Caotaamis-: 2601.,'BFair Stan cad:.,Tallahassii,F 3 3 9, Phone:.890=487�1824 The State'of Florida is an-AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privary Statement :': Accessibildy Statement:: Refund- StatemenC I Under. Florida law,email addtesses.are public records.if-you donoEwantyour e:mail"addre_s& released in -response to.a.public records..request;.do. notsend electronic maiYto this entity: Instead; contact the office by phone o' by tradif`ronatmait'Ifyodhave airy questions;.ptease contact 850.487:1995: "Pur'sua4 to Section 455.275(1), Honda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one: The emalls provided maybe used for official communication with the licensee. However email addresses are public record. If you do not wish to supplya personar address, please providi the Department with an email address which can be made available to the public. To determine If you area licensee under Chapter 455, F.S., please click ham. Product Approval Accepts: ®"NOW F-RO-1eCte'c Credit Card Safe I i I . 2 of 2 3/f7/2018, 7:39 AN �" 1 QOTR1N1*ERD TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ07070 (800) 516-1485 alBz?JORRIEARCI-I & DESIGN, LLCi tartificate of Authorization #f9503 353 CHRISl1AN SITEEf, UNIT#13 OXFORD, CT 06478 (203) 262-9245 This Evaluation Report is issued under Rule 61MO-3 and the applicable rules and regulations governing the use of construction materials in the gate of Florida. The documentation submitted has been reviewed by Fbbert Nieminen, RE for use of the rnrnrrh iie4 [inner the Florida Building (ode wnrrll Pnrlrin D dirling (ode PmeirJential \/hh ime The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code mctionsnoted herein. I _ • :: • , : TRi'8�1 • o n er, airmen. �s LABBJNa Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CON11NU®COMPuANcE This Evaluation Fbport isval d until such time asthe named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Fbport by the named client constitutes agreement to notify Fbbert Nieminen, RE if the product changes or the referenced Quality Assurance documentation changes. Trinity) 8;D requires a complete review of this Evaluation Report relative to updated Code requirementswith each Code Circle. Aw nam r. The Evaluation Peport number preceded by the words "Trinity) B;D EvaluaE@" may be displayed -in advertising literature. If any_portion of the Evaluation Report is displayed, then it shall be done in its entirety. INS:EMON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection, at the Job site at the request of the Building Official. This Evaluation Fbport consists of pages through,6. Prepared by: Robert J.M. Nieminen, RE Rorida Ibgistration No. 59166, Rorida DCAANE1983 The facsimile seal aopearingwas authoria:d by Fobert Keminen, P.Eon09/25/2017. This does not serve as an electronically signed doaiment. CgTnnca710N OFINCIFENDBJCE 1. Trinity) MD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates 2. Trinity[ B;D is not owned, operated or controlled by'any company manufacturing or distributing products it evaluates 3. Fbbert Nieminen, RE does not have nor will acquire, a financial interest in any company manufacturing or distributing products#or which the evaluation reports are being issued. 4, Fbbert Nieminen, RE does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) EF;D nor Fbbert Nieminen, RE are, in any way, the Designer of FL -cord for any project on which this Evaluation R--port, or previousversions thereof, istwas used for permitting or design guidance unless retained specifically for that purpose. r TRINITY J ERD ROORNG CbM PONENT L /AWAMON: i . SMrE Product Category: Pbofing SLb-Category: Underlayment Compliance Statement: TIC -BUILT Roof Unde ilayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliancewith the following sections of the 6�h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance issubjec t to the Installation Pbquirementsand Limitations/ Conditions of Use set forth herein. I 2. STANDARDS Section Property i / Standard Year 1504.3.1 Wind Pesistagoe FM 4474 2011 19A.3.1 Wind Uplift � UL1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4/ 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRS4/TRI April 2012 (04-12) 2012 3. FeumC s i Entity Examination Reference Date E D(TSM049) Physical Properties S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties SI0540.11.13 11/19/2013 BFD (TST6049) Physical Properties SE40540.03.14 03/26/2014 EFUOST6049) Physical Properties S44870.04.14-2 04/02/2014 BTD flTSM049) Physical Properties S44870.04.14-3 04/02/2014 HRD(TSM049) Physical Properties S44870.04.14-1 04/10/2014 B'D(TST6049) Physical Properties S44870.04.14-1 04/10/2014 BRD(TSM049) Physical Properties S43530.02.14-1-R1 05/14/2014 BFD(TST6049) Physical Properties SI3530.05.14 05/28/2014 BFD(TSM049) Physical Properties SI0540.10.14 10/31/2014 EFD(TSM049) Physical Properties SC7645.02.15 02/13/2015 9RD(TST6049) Accelerated Weathering 9D3520.04.15 05/27/2015 EFU OSF6049) Wind Fesistance 9 ;14045.05.17-R1 06/ 07/2017 UL, LLG (QUA9625) Quad ityControl Multiple-ListingR16814 12/10/2015 UL, LLG (QUA9625) Quality Control SarvioeOmfirmation Exp.07/1812020 4. PRoDUcf IDEB:RPTiom 4.1 Tri-Built 83nd-R Sq Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, 93S modified bitumen roof underlayment, with a 36-inch sheet width; meetsASTM D1970. 4. Tri-Built S' FiT Underlaymerrt is a self -adhering, non -woven Ipolyester fabric surfaced, SBS modified bitumen roof underlayment; meetsASTM D1970 and PFENTRI April 2012. 4.3 Tri-Built Snooth HT SA Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, S3S modified bitumen roof underlayment; meetsASTM D1970. I 5. LIMITATIONS 5.1 This is a building code evaluation. Neither Trinity) B:U nor Fbbert Nieminen, RE are, in any way, the Designer of FL -cord for any project on which this Evaluation Pbport, or previous versions thereof, is/was used for permitting or design guidance unlessretained specificallyfor that purpose. 5.2 This EvaluationPoportisnotforuseinFBCF-M-IZjurisdictions. 5.3 Fire Classification is not part of this Evaluation Pbport; refer to current Approved Fbofing Materials Directory for fire ratingsof thisproduct. Exterior Rwarch and Design, LLG Evaluation Ieport A42960,10.12-M Certificate of Authorization #9503 61H EDITION (2017) PBCNON-HVI QE IALUAMON R-16048-M TR-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 2 of 6 TRINITY i ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request. may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Fbof Covers: TABLIE1: RDOFaM3tOPPONS Underlaymeht Asphalt Nail On Tile Foam -On Tile Wood Shakes . Sate Shingles , mum, & Shingles Tri-Built Sind-R,%af de Yes i NoNoNo Yes Yes Underlayment Yes I Yes Yes Yes Yes Un 1 ; ent %e 5.5.1 Tri-Built Smooth HTSA Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam -On Tile" i `' i[@ MLbLof I' I lowing Approved N ad ' �underlayment combinations. TABLEIA:ALLOWABLETiLEADH®vE/ UND9:ZLAYMENT 03MBINATION9 Adhesive Rorida Product Approval I Underlayments ICPAdhesivesPolyset®AH-160 FL6332 Tri-Built &A HTTU Underlayment DowTileBondTM R22525 Tri-Built SA FIT TU Underlayment I 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand -RSA Shingle Underlayment, Tri-Built SA FITTU Underlayment or TI l Built booth !-11 v A Underlayment applied to: El Rywood; ASTM D41 primed plywood; OS3; ASTM D41 primed 053; Southern Yellow Pine; ASTM D41 primed Southern Yellow Rne; ASTM D41 primed structural concrete. While not required over plywood, i053or Southern Yellow Pine substrates, TRI-BUILTMaterials Group,.,LLC recommends priming the deck if1the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLCirequires tongue -and -groove board decking be covered with plywood or O53 prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Tri-Built Sand -RSA Shingle Underlayment, Tri-Built JA HFTU Underlayment or Tri-Built Smooth HT SA Underlayment applied to: I r7,11 Dens Deck Prime; ffiWFCCK Gypsum -Fiber Ibof Board. For installation under mechanically attached prepared roof coverings, insulation shall 'be attached per minimum requiremen t' f IM p"repared roof covering manufacUer' oducmpproval. For inMaMn rF under foam -on tile systems (Tri-Built SA FT TU Underlayment only), insulation attachment shall be cllecionw I by n of inlifiarl Ancinr) nrofc�,ional and installed based on testing of the in-ol'ation/underlayment .may....,. � .,, y..,�....... may. r ..� .. �. system in accordancewith FM 4,474, Appendix D or TAS114, Appendixd I I I I Pefer to Tile Manufacturer's or Adhesive Manufacturer's Rorida Product Approval for Overturning Moment Pedstance Performance. Exterior Pesearch and Design, LLC i Evaluation Feport A42960.10.12-F;6 Certificate of Authorization #9503 6EDITION (2017) FBCNON-M/I-IMIAWATION R-16048-M TRI-BUILTFbof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 \t TRINITY I ERD 5.6.3 Bond to Mechanically Attached Base Layer: Tri-Built Sand=RSA giinate lfnder'lavment; Tri-Built SIA HTTU Underlayfent or Tri-Built Smooth HT&A Underlayment applied to: t ASTM D226, Type I or II felt. iattached For installations under mechanically prepared roof coverings, base layer shall be attached.per minimum codified requirements. For installations under foam -on tile systems (Tri-Built SA HT TU Underlayment only), base layer shalllbe attached per minimum requirements of FRSA/TR April 2012.(04- 12). 5.6.4 Wind Pbsistance for Underlayment A! Istems.in.Foam-On ..Tile Applications: .IFFENTRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSaJTR April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing, pressure divided by 2 (the 2 to 1 margin of safety per FBC1504.9 has already been applied). Peferto FRSNTRI April 2012 (04-12), Appendix A, Table IA or FBC1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 bsf: Deck: Min. 15/32-inch; plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or FE9STO D rB:RlORPRMIR Underlayment: Tri-Built SSA HTTU Underlayment, self -adhered. #2 Maximum Design Pressure=-67.5psf: Deck: Sructural concrete to meet .project requirements to satisfaction of Authority Having Jurisdiction. Primer: SbpremaHastocol600c Underlayment: Tri-Built SSA HTTU Underlayment, self -adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-i n� ch APA-rated BCC plywood (may be installed C-side up) to meet project requirementsto satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splintersand wood projections shall be removed/sanded. Primer: (Optional):F�BSM.BGMORPFdkU ER Underlayment: Tri-Built SA HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids(bridging at side and end -laps. #4 -Maximum Design Pressure = -60.0 nsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sleet: Soprema Apra-G or Modified Supra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (F6C1517,5.2) Spoken 6 rich o.c,'a# the 4'ini h lapsand 6-inch o,c, in three; equally spaced rows in the center of the sheet. Underlayment: Tri-Built SSA HTTU Underlayment, self -adhered. Exterior FLsearch and Design, LLC Evaluation Report A42960.10.12-P6 Certificate of Authorization #9503 6'" EDITION (2017) FBCNON-M/I ZBtAWAmN R16048-F6 IA-BUILTFmof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 4 of 6 5.6.4.1 Fbr mechanically attached Base or -exceed -that required under F Alternatively, the maximum de design pressure determined in attachment density designed b •Commonly used methods are Application Standard MS 117. Sact ion 2.2.10.1 of FM Loss PreN 5.7 Exposure Limitations: ._ Ti i-omit ern-❑-R �,,, , Siiiigie ui exposed for longer than 30-day"l Tri Built 5A HTTU Under layrn 5.8 Tile-SippaaeUmitations(TAS1C ��-,! TRINITY ERD eet, the ma)amum design pressure for the selected assembly shall meet W TR-April 2012 (04-12), Appendix A, Table 1A. 1n pressure for the selected assembly shall meet or exceed the Zone 1 :cordance with FBC 1609. In this case, Zones 2 and 3 shall employ an a qualified design professional to resist the elevated pressure criteria. WSl/SPIRT WD1, FM loss Prevention Data. Sheet 1-29 and Roofing Assemblies marked with an asterisk" carry the limitations set forth in ntion Data Street 1-29 (January 2016) for Zone 213 enhancements aeidyrneni or Tri-Built Smooth i iT SA Underiayment shall not be left after installation it shall not be left exposed for longer than 180-days after installation. When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows, These slope limitations can only be exceeded by using battens during loading of the roof tiles. , TABLE2: TILEBJPPAGELim iwiONSFORDiR3:7-DBxTILEINSrAuAl10NS Underiayment 1 Tile Profile Staging Method Maximum Slope Rat Max 10-tilestack B;12 Lugged Max. 10-tile stack 512 Max 10-tile stack (bottom 24ile stack shall be inverted, followed by 8tiles high 6:12 on slope, asshown.below) Tri-PAjiltSAHTTU..'- Underlayment Lugged i Exterior F bsearch and Design, LLC Certificate of Authorization #.r9503 I I i e ED-nC (2017) FBCNON-HVI IZE/AWA'nON I TR-BUILTIeof Underlayments; (800) 516-1485 Evaluation Report A42950.10.12-M R-16048-M Revision 6: 09/ 2512017 Page 5 of 6 I - =' BUILT INSrAUATION: eats shall be installed in accordance with �- iotl TPo-BUILT Roof Underlaym, to. the.tj►7►itations set forth in S;et - 6.1 uirernents subject published installatlon.: req.;.. for protruding nail heads. SNeeP the substrate i spedf cs'nofeit beIcW-- if a liable). f�-fasten any loose decking panels, an d check ition and prime the substrate ( pP 6.2 dust and debris prior t aP to remove any TU Underla ment or Tri-Built Smooth I-ff 6.3 aa.;nd-RS4 Shin le Underla ment Tri-Built J A HT ent in FBC Table t Underl�v D1970 underlaym . Hance with the requirements for �ASTM 6.31 Shall be installed in Comp aced roof covering to be installed. 1507:1.1 for the type of .prep wa;a.a tao„ Tile�piaticat`ans LLC recommends priming the deck if the final roof While priming is optional, TRI-BUILT Materials Group, eel bade the first 3 cover is not slated for installation within 24�h rs. opmately 1oft of membrane and p pby4Fa41'et € rtFiic ofiedga i release film. membrane as far as possjble. `d part to -the substrate and unroll.theremainipg film diagonally while holding the N° ;.>> Adheretheexp peel -off the release 4-- h of membrane is in place, Once the entire length roll:fjtoom or hand=pressthe membrane into place to achieve a bond. membrane t:igltit . Rrrnly; the course below, sealed in accordance with I-lorizontal seam s should, be minimum 3-inches, configuredn o shed water• Vertical seams should e - inches and staggered not less thah 2 ft from vertical seams i in the LLCrequirements. ll_C recommends bade nailing TR-BUILT Materials Group, BUILT Materials Group, When installing at slopes above 8:12, TRI- overlap area at the top of the sheet at 12-inch o.c. paper and.oeriter sheet ForValleys and F�d9� Lit underlaYment into 4 to 6 #ooWlengths- romlthe centteerr of he valley or ridge in e and press sheet into place, oint and work upward. over valley or ridge. Drag I P he �� starting at lowest.p 9 each direction. Tyr valleys,, apply Underla ment only)using: he 6.3.3 Tile lications Tri-Built NTA pril 2012 (04 12) installation Manuak_and:Table 1 herein, L�ference is made to FRSgI instructions noted above asa guideline. applications, reference is made to action 5.6.4 herein for wind resistance limitationsth at For foam -on file cope of FRSATRI April 2012 (04-12). andl:or damage to, the fall outside the scope prevents --the slippage Tile shall be loaded and caged in a manner that . rials Q oup, LLCpublished requirements for file underlayment: See Table 2 herein, and TRI-BUILT Mater staging: IT 1MUI.FiEB4properly evaluate the installation of 7. required bLDING Pff y the Building pffidal or'Authority Laving Jurisdiction in order top p Y As i this product. i 8. MANUFACWFaNGPIANTS Gulfport, MS 9. .flt�Atlfi�'AiVCEH�►T�': UL, LL,C—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - BID OF B/AWATION FtPORT- I i Evaluation Import A429601 042- 6�" ®I11ON (2017) MCNON-WHMAUJABON I�vi§on.6:.0912512017 Exterior Researd� and pesign, U � page 6 of 6 Certificate of Authorization R9503 ;,Rajlu Fmof Underlayments; (800) 516 1485 i I