Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOIL NUCLEAR GAUGE
sly Nuclear Gauge Client: Project: pQ St Lu61(5 Report Date: 7/26/2018 Doyle Masonry, Inc. 17-6476.00 ,RNATIONP Test Method: ASTM D 6938 P.O. Box 12339 Doyle Masonry, Inc. 2017-2018 Master Port St Lucie Fort Pierce, FL 34979-2339 Agreement FBPECA#4930 Various Locations 607 NW Commodity Cove FL Port St. Lucie, FL 34986 Phone: 772-924-3575 I Fax: 772-9243580 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. Test # Of Date Proctor ID Method Classification N (pcf) N (pcf) (in) Compaction (e/,) Remark 18 7/24/18 P-1 N/A 11.0 108.0 9.8 105.0 12 97 95 / 105 Pass 19 7/24/18 P-1 N/A 11.0 108.0 9.8 104.9 12 97 95 / 105 Pass 20 7124/18 P-1 N/A 11.0 108.0 9.6 105.0 12 97 95 / 105 Pass 21 7/24/18 P-1 N/A 11.0 108.0 9.3 105.1 12 97 95 / 105 Pass 22 7/24/18 P-1 N/A 11.0 108.0 9.7 105.0 12 97 951105 Pass 23 7/24/18 P-1 N/A 11.0 108.0 9.6 104.8 12 97 95 / 105 Pass 24 7/24/18 P-1 N/A 11.0 108.0 9.9 104.9 12 97 95 / 105 Pass Test Information Gauge Test # Test Location - Elevation Reference Make / Model / SN / Calibrated Field Technician 18 Footing: 6311 Oleander Ave, Ft. Pierce, Map location 1 0-1 Troxler / 3430 / 24566 / Presson, Thomas 19 Footing: 6311 Oleander Ave, Ft. Pierce, Map location 2 0-1 Troxler / 3430 / 24566 / Presson, Thomas 20 Footing: 6311 Oleander Ave, Ft. Pierce, Map location 3 _ 0-1 Troxler 13430 / 24566 / Presson, Thomas 21 — Footing:_63-11-Oleander-Ave,-Ft-Pierce,-Map location 4 0-1 Troxler / 3430 / 24566 / _Presson, Thomas 22 Footing: 6311 Oleander Ave, Ft. Pierce, Map location 5 _ 0_1 --Trox ems/ 24566 / Presson, Thomas 23 FootingL6.311_Oleander-Ave,,-Ft-Pierce,-Mapiocatio 0-1 Troxler / 3430 / 24566 / Presson, Thomas 24 Footing: 6311 Oleander Ave, Ft. Pierce, Map location 7 0-1 Troxler / 3430 / 24566 / Presson, Thomas Remarks. Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. . • ENSF _ * : 6332188 * _ l Q a18 1�1�er�Tk��F •' ��, PPlgil?1 63218 Stat7/6Fo7,,' Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.