Loading...
HomeMy WebLinkAboutDENSITY OF SOIL IN PLACEi A. M. ENGINE T�' ESTING, INC. 590 N.W. MERCANTILELACE PORT ST LUCIE, FLORIDA 34986 OFFICE: (772) 9�24-3575 FAX: (772) 924-3580 DENSITY OF SOIL IN PLACE Client: Allied New Technologies, Inc. 3901 Northwest 115th Avenue Miami, Florida 33178 Contractor: Client Site: Allied Fort Pierce Plant, 9501 Rangeline Road Fort Pierce, St. Lucie County, Florida Main Building, Containment Area Report Date: May 12, 2009 Project No.: PSL 1940F Lab No.: 28 Technician: W. Hissong Page No.: 1 of 1 Permit No.: 0802-0116 Field Test Results Proctor Compaction Eleva- Test Date Location tion Dry Pass/ Dry Probe In Min No. Tested (ft) HCP HZO Density Depth Density Place Req'd Fail (cf) (in) (c (%) (%) 1 3/4/09 Map Location 1 01 - 1 75+1 7.2 1 116.2 12 115.6 100.5 95 P 2 Map Location 2 0; - 1 75+1 7.6 1 115.5 1 12 115.6 99.9 95 P 3 Map Location 3 0; - 1 75+ T6.1 1 117.6 1 12 115.6 101.7 95 P Remarks: • Elevations are below bottom of slab. • Field density tests were performed in general compliance with ASTM D2922, Density of Soil in Place by Nuclear Methods. • Hand Cone Penetrometer (HCP) tests, in conjunction with information about the soil type, are empirically correlated to the relative density of the subsurface soils. • Laboratory Proctor maximum dry density was determined in accordance with ASTM D1557. Distribution: Client - 2 VM Construction - 1 (Attn: Peter) Hand Deliver S: Bldg. Conve & AVS - 1 DWM/ah Reviewed by: A. M. ENGINEERING AND TESTING, INC. D/aW�'doler, P. . Florida Registration No. 60675 9 IlServer-amelcompanylAMDataUllied New Technologies, Inc. - Allied, Fort Pierce Plant - PSL1940IFoundation Padl28 - Main Building, Containment Area - Den. • PROPERTY LINE EXIST. S' CHAIN LINK FENCE PROPOSED SALT STORAGE BUILDING COIydRETE- -St'Ag 15,270 S.F. AREA' EXIST. ROPOSED SATURATOR PI COVERED CONCRETE LOADING DOCK & TANK STORAGE CONCRETE F.F.E.-3f.5 WITH TANK o EXIST. CONCRETE 2,000 SF. SLAB FOR TANKS EXIST. SLAB TANKS -PROPOSED PIPE BRIDGE 2 ABOVE EXISTING GRADE. (BY OTHERS) DRY RETENTION POND IN COVERED CONCRETE it EXIST. I STORY ALUMINUM BUILDING F.F.E.=28.25 NCRETE -:A6pbtj:f� Q -b WZIZZlh � LINE 2MMMARM z KEY PLAN I A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST: LUCIE, FLORIDA 34986 OFFICE: (772) 924-3575 FAX: (772) 924-3580 DENSITY OF SOIL IN PLACE Client: Allied New Technologies, Inc. 3901 Northwest 115th Avenue Miami, Florida 33178 Contractor: Client j Site: Allied Fort Pierce Plant, 9501 Rangeline Road Fort Pierce, St. Lucie County, Florida Main Building, South of Office Report Date: April 30, 2009 Project No.: PSL194OF Lab No.: 27 Technician: W. Hissong Page No.: 1 of 1 Permit No.: 0802-0116 Field Test Results Proctor Compaction Eleva- Max Test Date Location tion Dry Pass/ Dry Probe In Min No. Tested (ft) HCP HZO Density Depth Density Place Req'd Fail c in cf) %) 1 4/28/09 Northwest Corner 0 - 1 4.7 116.6 12 115.6 100.9 95 P 2 Center Area 0 - 1 6.1 1 115.5 12 115.6 99.9 95 P 3 Southeast Corner I 0-1 5.2 1 116.9 12 115.6 101.1 95 P Remarks: • Elevations are below bottom of slab. • Field density tests were performed in general compliance with ASTM D2922, Density of Soil in Place by Nuclear Methods. • Hand Cone Penetrometer (HCP) tests, in conjunction with information about the soil type, are empirically correlated to the relative density of the subsurface soils. • Laboratory Proctor maximum dry density was determined in accordance with ASTM D1557. j Distribution: Reviewed by: Client - 2 A. M. ENGINEERING AND TESTING, INC. VM Construction - 1 (Attn: Peter) Hand Deliver d . Moler, P.E. DWM/ah Florida Registration No. 60675 I i IlServer-amelcompanyL4MDataUllied New Technologies, Inc - Allied Fort Pierce Plant - PSL1940IFoundation PadU7 - Main Building, S. of Office - Den. I t� jj � ]r � \ J A. M. ��i ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST I LUCIE, FLORIDA 34986 OFFICE: (772) 924-3575 FAX: (772) 924-3580 DENSITY OF SOIL IN PLACE Client: Allied New Technologies, Inc. I Report Date: March 24, 2009 3901 Northwest 115th Avenue Project No.: PSL194OF Miami, Florida 33178 Lab No.: 25 Contractor: Client Technician: W. Hissong Site: Allied Fort Pierce Plant,_9_501 Rangeline Road I Page No.: 1 of 1 Fort Pierce, St. Lucie County, Florida Permit No.:- . 0802-0116 - `-i Main Building Slab Area, Area # 1 Field Test Results PMaX°r Compaction Eleva- Test Date Location i tion Dry Probe Dry In Min Pass/ No. Tested Ut) HCP HZO Density Depth Density Place Req'd Fail cf) (in) (cf) % (% 1 3/23/09 North End, Center 1 0 - 1 70+ 8.7 116.2 12 115.6 100.5 95 1 P 2 Center Area 0 - 1 70+ 11.21 115.1 12 115.6 99.6 9did 3 South End, Center 0-1 70+ 9.5 116.6 12 115.6 100.9 9 Remarks: I • Elevations are below bottom of slab. • Field density tests were performed in general compliance with ASTM D2922, Density of Soil in Place by Nuclear Methods. • Hand Cone Penetrometer (HCP) tests, in conjunction with information about the soil type, are empirically correlated to the relative density of the subsurface soils. • Laboratory Proctor maximum dry density was determined in accordance with ASTM D1557. I Distribution: Reviewed by: Client - 2 A. M. ENGINEERING AND TESTING, INC. VM C-CotIonstruceetiion - 1 (Attn: Peter) Hand Deliver iConBe g& AVS 1- 1 r� DOZdMoler, P.E. DWM/ah Florida Registration No. 60675 tS't A J� M �Lc'6oc% ° 0 �L O�d7 IlServer-amelcompanyL9MDataUllied New Technologies, Inc. !-Allied Fort Pierce Plant - PSL1940Woundation Pa&25 -Main Building Slab Area, Area l - Den.