Loading...
HomeMy WebLinkAboutBUILDING PLAN PAGE 31-33RETURN AIR V FAN ENABLE HUMIDITY FIRE ALARM STATUS DISABLE SENSOR AI SHUTDOWN DI DO HTE RELAY AND SMOKE DETECTOR CIRCUIT WIRING (BY DIV. 16) SMOKE DETECTOR SD ELECTRIC TTTE COOLING HEATING & FILTER COIL COIL SD OA C V SA J0 ROOM COMPRESSOR 1 DO THERMOSTAT STATUS COMPRESSOR 2 DO DO ELECTRIC HEAT STATUS STATUS Al SPACE TEMP. (WHERE APPLICABLE) Al SPACE SETPOINT CONTROL LEGEND EXISTING CONTROL CONDUIT NEW CONTROLS CONDUIT CONNECT TO EQUIPMENT AS INDICATED. AI ANALOG INPUT AO ANALOG OUTPUT DI DIGITAL INPUT DO DIGITAL OUTPUT CONTROL NOTES 1. PROVIDE FIELD INSTALLED TERMINAL EQUIPMENT CONTROLLERS. 2, MINIMUM CONDUIT SIZE SHALL BE 3/4". 3. CONTROLS MANUFACTURER IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL CONDUIT AND WIRING NEEDED TO COMPLETE THEIR WORK. eROOFTOP AIR CONDMONING UNfT - RTU-M M-2 NOT TO SCALE CEILING HUUI-- I car -2 SCALE: 1/4"=1'-O" )P AIR IONING UNIT E NEW EQUIPMENT CURB. TAILS ON SHEET M-3 TION TO FULL SIZE OF UNIT CONNECTION EXISTING CONTROL WIRING CONDUIT ROOF PLAN - MECHANICAL SCALE: 1/4' = 1'-0' ERMINAL EQUIPMENT ONTROLLER SEE ONTROL DWG ON HIS SHEET p o = 4i (n = m Z a O o Q . ri o W 0 U� �R V WM w M L.V a � w 0- Cf m 06 (1) � I— c°O�o VCD oCD U Ill Q Z e� m � m M m a:Z (w /1N z Y W v vin Qo 0 in N w z U Q 0 o z 00 oW Qr� r),oz o Q�U C U zCD� 0 �U(n Q � SHEET NUMBER M-2 OF 3 G CLEANOUT ROUTE TO ROOF DRAIN AIR HANDLING UNIT EACH DIMENSION EQUAL OR GREATER THAN THE NEGATIVE STATIC PRESSURE OF THE FAN eCONDENSATE DRAIN DETAIL M-3 NOT TO SCALE ADJUSTABLE PITCH — MOTOR SHEAVE ON BELT DRIVE UNITS MOTOR & DRIVE OUT OF AIR STREAM MOTOR DOME RUBBER ISOLATOR ALL ALUMINUM WHEEL HUB & HOUSING DISCHARGE DOME W/ - BIRDSCREEN STATIC PRESSURE -� PROBE 1/8' DIA. TUBE RUBBER GASKET BETWEEN CURB & FAN HOUSING ANCHOR FAN TO CURB SEAL ALL CURB PENETRATIONS RUN FLASHING UP UNDER FAN BASE BACKDRAFT DAMPER EXHAUST AIR DUCT PROVIDE SOLID STATE SPEED CONTROL WITH DIRECT DRIVE FAN U.L. APPROVED DISCONNECT SWITCH UNDER HOOD MOTOR VENTILATION fOPENING eEXHAUST FAN DETAIL M-3 NOT TO SCALE ROOFTOP AIR CONDITIONING UNIT FLASHING CANT ROOF INSULATION —� METAL DECK - PRE-FAB ALUM. ROOF CURB W 2" RIGID INSULATION AND BUILT-IN CANT PROVIDE RAISED ANT AS REQ'D) SET CURB IN ROOFING CEMENT AND FASTEN TO ROOF DECK. ROOF STRUCTURE - SEE ARCH. & STRUCTURAL PLANS FOR DETAILS Fmm 2 tuuirMt 3 NOT TO SCALE Ell, WOOD BLOCKING ROOF CURB DUCTWORK L 3x3x5/16 L 6x4x5/16 NOTE: ALL WELDED CONSTRUCTION O AIR DISTRIBUTION SCHEDULE �I PLAN__T� DESCRIPTION MATERIAL FINISH MANUFACTURER & MODEL N0. ACCESSORIES MARK QA 24x24 FACE, SUPPLY DIFFUSER ALUM WHITE TITUS TMS-AA 2 QB 12x12 FACE, SUPPLY SECURITY DIFFUSER ALUM WHITE TITUS SG-TDC-AA 1 © 24x24 RETURN & EXHAUST GRILLE ALUM WHITE TITUS 50F 2 Q 40x24 SMOKE EXHAUST GRILLE ALUM WHITE TITUS 50F 2 A 1. PROVIDE COMPLETE WITH REAR ANGLE FRAME AND TAMPER PROOF FASTENERS. 2. PROVIDE LAY -IN FRAME FOR INSTALLATION IN AN ACOUSTICAL TILE CEILING. MUM= 1. PAINT ALL DUCTWORK VISIBLE THROUGH GRILLE MATTE BLACK. F2. no. crv.av c /1 cxfw nca-aMt CFM RANGE n u NECK SIZE CFM RANGE NECK SIZE - -- — -- CFM RANGE - NECK SIZE CFM RANGE NECK SIZE 25 - 50 4"0 0 - 20C 8"0 500 - 625 14"0 201 - 350 1 10"0 626 - 710 15"0 51 - 140 6"0 351 - 499 12"0 141 - 210 8"0 NOTE: UTILIZE NECK SIZE ABOVE ONLY IF NOT INDICATED ON PLANS. NOTES: 01 HANG FROM STRUCTURE ABOVE. TOP CHORD OF JOIST. 02 PROVIDE FULL PERIMETER SUPPORT ON OUTSIDE OF INSULATION OF ALL ROUND DUCTWORK. 03 SUPPORT RIGID DUCTWORK ON EACH SIDE OF FLEXIBLE CONNECTION. ® MINIMUM 1.5 TIMES THE DIAMETER FOR ALL ELBOWS. Q5 2 INCH BATT INSULATION OVERLAPPING EDGES OF CEILING DIFFUSERS BY 2 INCHES. © DRAW -TIGHT OR SCREW TIGHT BANDS OF NON -CORROSIVE MATERIALS TO ATTACH INNER LINER OF FLEXIBLE DUCT TO RIGID DUCTWORK. 70 RECTANGULAR TO ROUND TRANSITION. ® INSULATED RIGID ROUND DUCTWORK. Eo 09 INSULATED RECTANGULAR DUCTWORK. ® VOLUME DAMPER WITH STAND-OFF FOR INSULATION AND LOCKING QUADRANT PLATE. 11 RECTANGULAR TAP WITH 45 DEGREE TRANSITION. © BELL MOUTH ROUND TAP. UTILIZE METHOD "B" WHEN FLEX DUCT IS EQUAL TO OR GREATER THAN REC- TANGULAR DUCT DEPTH. © INSULATED SUPPLY AIR DUCTWORK. eSINGLE DIFFUSER TAPS DETAIL M-3 NOT TO SCALE EXHAUST FAN SCHEDULE MARK EF-BOOK EF-M MANUFACTURER GR_EENHECK GREENHECK MODEL G-85 CUBE-150-7 ■j1`J SERVES BOOKING SMOKE EXHAUST FOR BOOKING AIR FLOW CFM 325 2240 STATIC PRESS. IN. WG. 0.125 0.75 DRIVE TYPE DIRECT / CENT. BELT / CENT. FAN TIP SPEED 3701 4961 H.P. RPM 1/30 / 1300 3/4 / 1140 VOLTS PH 115V/1PH 460V/3PH OPERATING WEIGHT LBS. 23 65 ACCESSORIES 1 & 2 7E 1 NOTES OCE8801`1813 1. PROVIDE COMPLETE WITH ROOF CURB, BIRD SCREEN, DISCONNECT SWITCH AND BACKDRAFT DAMPER. 2. PROVIDE SPEED CONTROLLER. DX ROOFTOP UNIT SCHEDULE MARK RTU-M _ SERVES BOOKING MANUFACTURER_ TRANE MODEL TCD074 cAu TOTAL AIR FLOW (CFM) 2535 OUTSIDE AIR FLOW (CFM) 400 EXT. S.P. IN. WG. 1.0 DRIVE TYPE BELT CENT. H.P./RPM 1 1725 VOLTS/0 460 3 ENT. AIR TEMP. DB WB 78 65 LVG. AIR TEMP. DB WB 58 56 SENS. CAPACITY MBH 55.4 TOTAL CAPACITY MBH 68.6 FACE AREA SQ. FT. 7.88 ROWS FINS PER INCH 3 15 IFR_.F(`TR(_ HFATM COL NUMBER OF STAGES 1 TOTAL KW 18 VOLTS/0 460/3 NUMBER OF FANS 1 HP EACH 0.25 F.L.A. 0.9 NUMBER OF COMPRESSORS 1 R.L.A. 10.0 L.R.A. 71 AYATPU a FrTarAL DATA M.C.A. M.O. C.P. 31.1 35 _ VOLTS 0 460/3 OPERATING WEIGHT LBS. 765 ACCESSORIES 1 _ SYSTEM E.E.R. 10.0 SIZE (IN.) 16x25x1 QUANTITY _ 3 TYPE THROWAWAY 1. PROVIDE SINGLE POWER ENTRY KIT. 2. 3. IOUTEH 1. 2. 3. d 0 �r- m W eb m� rN m C N 0�m � a U g o R o 13 cn R w cd = r r m ^ m C, !a� w X a w pp ct U rn rn I N I M a s � o � Z a 0 Q 1� Q w U rn � R V U W M a M Li WM Q� o W od(j) 00 OV CD CD U W c Q Z e<I mV m N N " M W cr It w' z It w N Q 0 w z � U Q o z � O z � � W f-- � >-= Q cj:� o z o C v 0 oUcn o Q � SHEET NUMBER M-3 OF 3 ELECTRICAL SYMBOL LIST NOTE: NOT ALL SYMBOLS INCORPORATED ON THIS SYMBOL LIST MAY BE USED ON THIS PROJECT. LKWfM 8YMBOL3 FA 2x4 FLUORESCENT LIGHT FIXTURE, LETTER INDICATES FIXTURE TYPE ® 2x4 FIXTURE ON EMERGENCY POWER W/ BATTERY PACK EMERGENCY LIGHT BATTERY PACK WALL MOUNTED FIXTURE ON EMERGENCY POWER 4 WALL MOUNTED FIXTURE EXIT LIGHT — WALL MOUNTED — ARROW SHOWS DIRECTION, SOLID QUADRANT INDICATES FACE EXIT LIGHT — CEILING MOUNTED — ARROW SHOWS DIRECTION, SOLID QUADRANT INDICATES FACE $a SINGLE POLE TOGGLE SWITCH, SUBSCRIPT INDICATES FIXTURE CIRCUIT CONTROLLED (48"A.F.F.) $3 THREE—WAY TOGGLE SWITCH (48" A.F.F.) $K KEY OPERATED SWITCH (48" A.F.F.) POWER/GENERAL LEGEND @= DUPLEX RECEPTACLE, FLUSH MOUNT (18" AFF) x WP = WEATHERPROOF GFI = GROUND FAULT INTERRUPTER x EWC = ELECTRIC WATER COOLER MOUNT BEHIND ACCESS PLATE IG = ISOLATED GROUND DUPLEX RECEPTACLE, MOUNT ABOVE COUNTER TOP H = INSTALL HORIZONTAL E = EMERGENCY OO JUNCTION BOX, CEILING MOUNT JUNCTION BOX, WALL OR FLOOR MOUNT � 3P C� DISCONNECT SWITCH — 3P, 30A., NON —FUSED INDICATED 0, CEKP COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT SWITCH, TYPE AND SIZE INDICATED. SEPARATE ITEMS ARE ACCEPTABLE aMOTOR, MOTOR NUMBER — REFER TO SCHEDULE (OR) MOTOR HORSEPOWER DRY TYPE TRANSFORMER, DESIGNATION INDICATED PANELBOARD — 120/208V. p PANELBOARD — 277/480V —P UNDERFLOOR RACEWAY: P=POWER, C=COMMUNICATION —C— HOMERUN TO PANEL, ONE ARROW PER CIRCUIT BRANCH CIRCUIT CONDUCTORS IN CONDUIT, CROSSMARKS INDICATE NUMBER OF CONDUCTORS. EQUIPMENT GROUND REQUIRED BUT NOT SHOWN. TWO CONDUCTORS PLUS GROUND UNLESS OTHERWISE SHOWN. NORMAL CIRCUIT —P— PRIMARY POWER CABLE FIRE ALARM SYMBOLS ❑F FIRE ALARM PULL STATION (48" AFF) Qs FIRE ALARM SPEAKER (WALL MOUNTED) ® IONIZATION TYPE SMOKE DETECTOR (CEILING MTD) DUCT MOUNTED SMOKE DETECTOR s TELEPHONE/DATA/ PUBLIC ADDRESS (P.A.) S =SUPPLY DUCT R =RETURN DUCT 0 FAN CONTROL RELAY � FIRE SPRINKLER FLOW SWITCH � FIRE SPRINKLER TAMPER SWITCH W I TELEPHONE AND/OR DATA OOUTLET, FLUSH MOUNT (18" A.F.F.) STUB INTO CEILING SPACE WITH X" CONDUIT W = HIGHER MOUNT TO MEET ADA REQUIREMENTS ® PLYWOOD BACKBOARD, 3/4"THK x SIZE AS SHOWN ON PLANS (PAINT W/2 COATS OF FIRE RETARDENT GRAY PAINT) is INSTITUTIONAL PUSHBUTTON STATION O4 CAMERA TEMPORARY CALL BOX EXISTING "MX" PANEL " J PANEL 8f/ PANEL "BE2" PANEL "BE1"— d'3 y NEW POLE, CAMERA, AND CALL BOX LOCATION EXISTING CCTV SWITCHES EXISTING INTERCOM PANEL I EXISTING DOOR CONTROL PANEL EXISTING LIGHTING POLE \ NEW POLE LOCATION EXIST. CALL BOX / EXISTING CIRCUIT 1 EXIST. LIGHT POLE, POLE FOUNDATION AND CAMERA OELECTRICAL SITE PLAN \ S\ o N b o co ,M4 U� U i q d REFERENCE NOTES: " O1 RELOCATE EXISTING CAMERA TEMPORARILY TO THIS W o m LOCATION. EXTEND (1) RG59 COAX, (2) #12, (1) #12 GND. � t' IN 3/4" C. AND (1) #12 TSP. G ac O2 EXTEND EXISTING SALLY PORT GATE CONTROL AND Fr q r POWER TO TEMPORARY GATE OPERATOR. EXTEND (10) U 05 I #16 IN 3/4" C. FOR CONTROL AND (3)#10, (1)#10 GND IN ,w mo-r 3/4"C. FOR POWER. n O PROVIDE A FIBERGLASS PULL BOX W/GASKETED, m x SCREW —ON LID TO ALLOW CONNECTION OF TEMPORARY d GATE OPERATOR TO EXISTING SALLY PORT GATE CONTROL p o CIRCUIT AND POWER. PROVIDE A LABEL AT THE EXISTING v CENTRAL CONTROL STATION GATE CONTROL PANEL IDENTIFYING THE TEMPORARY GATE CONTROL BUTTON. ® PROVIDE FIBERGLASS JUNCTION BOX W/GASKETED, SCREW —ON LID AND (4) #12 TSP IN 1" C. ROUTED TO CENTRAL CONTROL STATION INTERCOM PANEL THRU NEW CONDUIT FOR TEMPORARY CALL BOX. SEE SHEET E-3 FOR NEW CONDUIT ROUTING TO CENTRAL CONTROL STATION. 5O RELOCATE EXISTING LIGHTING POLE, POLE FOUNDATION AND CAMERA TO NEW LOCATION. EXTEND EXISTING CAMERA RG59 COAX CABLE, (2) #12, (1) #12 GND. IN 3/4" C. AND (1) #12 TSP TO NEW CAMERA LOCATION. PROVIDE A FIBERGLASS JUNCTION BOX W/GASKETED. SCREW —ON LID SIZED AS REQUIRED TO ALLOW EXTENDING THE CONDUIT. © RELOCATE EXISTING LIGHTING POLE AND POLE FOUNDATION. EXTEND EXISTING LIGHTING POLE FEEDER TO NEW POLE LOCATION. (2) #8, (1) #10 GND. IN 2" C. TO PANEL "AE2". O7 RELOCATE EXISTING CALL BOX TO NEW LOCATION. EXTEND EXISTING CALL BOX WIRING (1) #12 TWISTED SHIELDED PAIR IN 3/4" C. TO NEW CALL BOX LOCATION. ® EXTEND EXISTING LIGHTING POLE CIRCUIT TO NEW POLE LOCATION. (2) #8, (1) #10 GND. IN 2" C. EXISTING POLE