Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGk ees Home 1 Log in i Uscr RegistrationProduct Or Approval am USER; Public User : nv u.t aaIIrDyol Menu - 'rn r,ii T FL Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name wj the Evaluation Report .Florida License Quality Assurance Entity Quality Assurance Contract Expiratio Validated By SCANNED' F l tUY'tl•U'}4 t Submit surcharge Stats 6 taus publications r Flit staff i ias site Map j tntks ` Search > AocNntion t,M > Application Detail FL17022-R7 Revision 2017 Approved 08/18/2017v.date reapply 08/21/17 Extreme Metal Fabricators; LLC 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Richard McKuhen qvalidation@yahoo.com Richard McKuhen 2160 SW Portia Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L Evaluation Report - Hardcopy Received to developed LOCKE BOWDEN n PE-497044 Keystone Certifications, Inc. Date 04/22/2024 Zachary R. Priest, P.E. validation Checklist- Hardcopy Received Certificate of Independence I Referenced Standard and Year (of Standard) I Equivalence of Product Standards Certified By Sections from the Code FL17022 R7 COT ct 17022 1 S t! RiMP cvr ndr Standard ymdr TAS 125 2003 UL1897 2012 UL 580 20116 X Palm City, FL 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Yield strength: 50 kst min.; Deck w/ mein. 0.42 specific ! Rib Height 3/8" Corrosion Resistant Compliant: FBC Fastener 3 (Method 1 Attachment): 3/16" min. thru deck or 5/8" embed requirements) Fastener 2 (Method 2,3, & 4 Attaches penetrate 3/16" min. thru deck or Si to meet requirements) Underlayment: To be compliant wit! Slope: Shall be in compliance with FBC Sec.1:507.4.2 led to min.15/32" plywood or Wood with screws. 24" Coverage c.1507.4.3 x 1-1/2" Hex -Washer Head good screw* to penetrate Mt into wood plank. (*or sufficient length to meet t): #10 x 1-1/2" Hex -Washer dead wood screw* to embedment into wood plank. (*or sufficient length FBC Sec. Chart 1S07.1.1 Sec.1507. .See Fastenei,altAirhi➢ Anna' C►aorifii afirsssc fth—N — Instal[ Details: Table A AIE®wabEe Loads METHOD 1 METHOD Z METHOD 3 METHOD 4 1 DESIGN PRESSURV -93.5 PSF -101 PSF f -228 PSF ROW SPAaNG 1fi" o.c. 16" ox. 8" O.C. 6" ox. FASTENER SPAtIRA111- (Al rlNG Panel width) 12" O.C. 12" o.c. 12" o.c. 12" FASTENER SIZE j #9 #10 , #10 O.C. ##10 Reference Data: ARCHITECTURAL TESTING, INC- TST ID#: 9S27 UL 580-06 & 1897-04t Test Report 125893.0I-450-9.8 05/02/14 Test Report F3366.Oi-450-181211ans TAiS 125-03 Test' Report D05893.02-450-18 07/22/14 *EQZALENCY--UL 1897-04 is equivalent to tesisiandard UL 1897-12 *Design pressure margin of safety 2c1 ,ttlfirrt��g ki Locke Sowden, P.E. does not have, not will acquire a financial inl�tg a co{ir1mysaiactusmg or distributing products under this evaluation. v� L Locke Bowden, P.E. is not owned, operated, or controlled by a& coaipanVorn4gPfa�tureq or is#ributing products under this report. Z 6 , A NAL 's a::t.7t nts I=L97022.1 5V Crimp i Limitations: 1. Undedaymentto be compliance with current Flai 2. Minimum slope to be compliant with Florida Buii( 3. Products are compliant for State of Florida prodt 4. Engineering analysis for "project specific approv 5. Fire classification is not part of this acceptance. 6. Support framing in compliance w/FBC 2017 6u E Structural Loading. 7. This report does not imply warranty, installation, Dedc: -15W -W=di Nominal O.C. Steel), 24`° Wide Roof Panel Details a Building Code (FBC)2017 61h ed. ig Code 2017 6th ed., and per with Manufacturers installation reference. approval per Rule 61G20-3. Compliance Method: 1-D by local authorities w/jurisdlction is allowed by other registered engineers. tear diaphragm values are outside this report. , Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for or product use outside of this report. -- Festeners- nBx1-12°hfi0. o: :10'-1-11rMin. perTa vW for Row swCrimpRoof Panel Spacing and Design Pressures Hex Was^erHead Wood Screvis i rsFn—WAL STRAMS Panel Profile Nominal 12" O.C. Fasten X 1-112" Min. or 010 x 1-1/2" iVlin. per -fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table " A" forSpacing Along Panel Overlap Length Jam- Deck-15/32" or greater Plywood, or -Mod plank