HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSCANNED
LUi rlp rmuniv
i
"iSw �"
BCIS Hame 1 Log In User Registration Ho[ opi<s i SubmitSurcliarge Stars Fi Farts i I ublications I FBC Staff BCIS Site Map Uaks i Search
I"it+iCid ^.:...
(rig -ill � Product Approval
USER:. Public User
Rrroh;St a:;om::al Nlent, > erldu<Se. c:cn > A:?pkaiion L;<t > Application Detail
x�ri,'i s4 yr°. 1
FL FL16048-R6
Application Type Revision
Code Version 2017
Appiicatioh Status Approved THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
Comments REQUIRED BY FIELD INSPECTORS THAT
Archived MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Product Manufacturer Tri-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford, NJ 07070���I
(800) 516-1485 L�l
david.ruiz@tribuiltmg.com
ST. LUCIE COUNTY g� p BUILDING DIVISION
Authorized Signature David Ruiz REVIEWED FOR COMPLIAN �tjl david ruiz@tribulltmg.corrt REVIEWED BY �
Technical Representative David Ruiz DATE c
Address/Phone/Email 250 Route 17 North PLANS AND PERMIT MUST BE KEPT ON JOB
East Rutherford, NJ'07073 SITE OR NO INSPECTIONS WILL BE MADE
(201)842-2449
david.ruiz@tribuiltmaterialsgrou p.com
Quality Assurance Re
Address/Phone/Ernail
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
i...I Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Repot
Florida License
PE-59166
Quality Assurance ntity
UL LLC
Quality Assurance ontract Expiration Date
07/18/2020
Validated By '
John W. Knezevich, PE
11-1
Validation Checklist - Hardcopy Received
Certificate of Ind'pendence Fi...t, ga£1 RG C_OT ?.OI7 01 CL'I !ieminen: tdf
Referenced St a dard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM G155
2005
FM 4474
2011
fRSA/TRI April 201.2 (04-1Z)
2012
UL1897
2012
Equivalence pf Product Standards
Certified By I
Sections from the Code
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
FILE COPY
Product Approval Method I Method 1 Option D
Date Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/1017
Summary of Products
I —
FL #
Model, N mber or Name
Description
16048,1
1 TRI-BUILt Roof Underlayments
Self -adhering, modified bitumen roof underiayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 IT 7 S 7' 09 INAs_ FR TRf-
Approved for use outside HV : Yes
FijfTI.T t3a1'7ERI..F{YNf3=�'TS Ell 1604S-R6.;x1f
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure oted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop fie self -adhering
FL16048 Ro AE 20:7 09 _ETL'AL_F_R 1 Rtr
underlayment for one particular pplication. See ER Section
RVll �N I fi; pY+7.E[i �- F�ntI48-R6.n
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
eaok nett
Cont. ct Us.:: 2601'olalr Stone Road.Tallohossee Fi, 32399 Phone: 950-487-1824
The State or Florida is an AAME01ernployer. Cnnyrinht 2007-2013 State of Florida. ;: Privacy StatemenC :: Accessiblif y Statement :: Remind Statement
Under Flodda law, email addresses an, ublic records. 11 you do not want your e-mail address released in response to a puviic-records request, do not send electronic
mail to this entity. Instead, WilLact the fit,
. by phone or
by traditional mall. If you have any questions, pleasecontact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Stitutes, effective October , 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may he used for offitiai tumn—iratian with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
pi ease provide the Department wkh a email address which ran be made available co the public. To determine if you area ficensee under Chapter 455,. F.S., please
click here . -
Product Approval Ac-pts:
r
credit Card
Safe
EXTERIOR RESEARCH & DESIGN, LLC.
Certijrcate of Authorization #9503
3.53 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A42960.10.12-R6
PO Box 70 FL16048-R6
Rutherford, NJ 07070 Date of Issuance;10/25/2012
(800) 516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Ru a 61G20-3 and the applicable rules and regulations governingthe use of
construction materials in the State of Flori a. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the FII rida Building Code and Florida Building Code, Residential Volume. The
products described herein have been ev luated for compliance with the 6"' Edition (2017) Florida Building Code
sections noted herein. II
DESCRIPTION: TRI-BUILT Roof
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation RI6port is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation chang s, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named lient constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assu ance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated CQde requirements with each Code Cycle..
ADVERTISEMENT: The Evaluation Report (Dumber preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of thi I entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available fo) inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pagq's 1 through 6.
Prepared by:
..._--�-^ "�`� _•�¢�'\M4N�s.. ,tom
Robert J.M. Nieminen,P.E.
'.JJJiq�u,.U�H`' The(aaimilc seal appearing was authorized by Rolx:rtNieminen,
Florida Registration No. 59166, Florida 0 ANE1983 P.E. on us/25/2017. This does not serve as an etectronicaih signed
document
CERTWICATrON OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not dwned, operated of controlled by any company rnanufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not havel nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. INeither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose. l
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1.
SCOPE:
Product Category: Roofing
Sub -Category: Underla ment
Compliance Statement: TRI-BUILT oof Underlayments, as
produced by TRI-BUILT Materials Group, LLC, have
I
demonstrated compliance with the folIll�owing sections of the 6u'
Edition (2017) Florida Building Cade through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2.
STANDARDS:
Section roperty
Standard Year
1.504.3.1 Ind Resistance
FM 4474 2011
1504.3.1 ind Uplift
UL1897 2012
1504.6 celerated Weathering
t�ysical
ASTM G155 2005
1507.2.4 / 1507.1.1, 1507.2.9.2 Properties
ASTM D1970 2015
1507.3.3 Physical Properties
FRSA/TRI April 2012 (04-12) 2012
3.
REFERENCES:
Enti Examination
Reference Date
ERD (TST6049) Physical Properties
S40540.02.13-1 02/19/2013
ERD (TST6049) Physical Properties
S40540.11.13 12/19/2013
ERD (TST6049) Physical Properties
S40540.03.14 03/26/20,14
ERD (TST6049) Physical Properties
S44870.04.14-2 04/02/2014
ERD (TST6049) Physical Properties
S44870.04.14-3 04/02/2014
ERD (TST6049) Physical Properties
S44870.04.14-1 04/10/2014
ERD (TST6049) Physical Properties
S44870.04.14-4 04/10/2014
ERD (TST6049) Physical Properties
543530.02.14-1-R1 05/14/2014
ERD (TST6049) Physical Properties
S43530.05.14 05/28/2014
ERD (TST6049) Physical Properties
S40540.10.14 10/31/2014
ERD (TST6049) Physical Properties
SC7645.02.15 02/13/2015
ERD (TST6049) Accelerated Weathering
SC8520.04.15 05/27/2015
ERD (TST6049) Wind Resistance
SC14045.05.17-R1 06/07/2017
UL, LLC. (QUA9625) Quality Control
Multiple -Listing R16814 12/10/2015
UL, LLC. (QUA9625) Quality Control
Service Confirmation Exp. 07/18/2020
4.
PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen r of underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof unde I ayment; meets ASTM D1970 and
FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen ioof underlayment; meets ASTM D1970.
S.
LIMITATIONS:
5.1 This is a building lcade evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Reco Id for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to c,irrent Approved Roofing Materials
Directory for fireiratings of this product.
Exterior Research and Design, LLC. i Evaluation Report A42960.10.12-R6
Certificate of Authorization N9503 I 6' EoITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
I TRI-BUILT Roof Underlayments; (800),516-1485 Revision 6: 09/25/2017
Page 2 of 6
0
5.4 TRI-BUILT Roof Underlaym
specifically referenced withi
Authority Having Jurisdiction
prepared roof covering.
5.5 Allowable Roof Covers:
TRINITY; ERD
is may be used with any prepared roof cover where the product is
FBC approval documents. If not listed, a request may be made 'to the
it approval based on this evaluation comoined with supporting data for the
';' .,:.,. d _a �.,• ..._ .-: "`TAIiLEI RoOFC.OVERxQPI�UN`S s.
.. ..-, .... -,. .�. _... ..., .. ....-. .. ...__ _.,... a
I
Underlayment
Asphal
I
Nail -On Tile
j
i Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Shingles
I Underlayment
Yes
No
No
No
Yes
Yes
'
.._........_.__-_....... .. .. ... _...... ........ .._
Tri-Built S/A HT TU
Underlayment
Ye
_-.._............... _.L
Yes
__....
Yes
See 5.5.1
Yes
Yes
Yes
_....................._..............
Tri-Built Smooth HT S/A
Ye
No
No
Yes
Yes
Yes
Underlayment
S_5.1 "Foam -On Tile" is Iimitedlto use of the following Approved tile adhesives / underlayment combinations.
' T/16LE11 ALLOWABLETtLEADfIESIVE%IINDERtAYMENTC01V1'SINAT[Ci[v15t
Y ! _F,;..:'.•
Adhesive
Florida Product Approval I Underlayments
ICP Adhesives Polysete AH-160
FL6332 Tri-Built S/A HT TU Underlayment
Dow TileBond'"
FL22525 i Tri-BuiltS/A HT TU U.iderlayment
5.6 Allowable Substrates: I
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shngle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applie to:
Plywood; ASTM D141 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern1.61low Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends primithe deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materialsn Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installa ion of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA ishingle .Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation unIder mechanically attached prepared roof coverings, insulation shall be attached per
minimum require ents of the prepared roof covering manufacturer's Product Approval. For installations
under foam-o❑ tiie systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by �a qualified design professional and installed based on testing of the insulation/underlayment
system in accordaince with FM 4474, Appendix D or TAS 114, Appendix J.
i
I
I
Refer to Tile Manufacturer's orlA dhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance,
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Cerdjrkate of authorization #9503 EDITION (2017) F8C NON-HVHZ EVALUATION rLiG048-AG
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
i
5.6.3
"I'll TRI ] RD
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
D ASTM D226, Type I or II f It.
For installations under mec �hents.
anically attached prepared roof coverings, base layer shall be attached per
minimum codified require For installations under foam -on the systems (Tri-Built S/A HT TU
Underlayment only), base ¢ayer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12). I
5.6.4 Wind Resistance for Undel-lavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind up Ift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms art of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems th t are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, an reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix.A, Table 1A &
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 sf:
Deck: Min. 5/32-inch plywood to meet project requirements to satisfaction of Authority
Havi g Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built 5/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pres9Ure = -67.5 psf:
Deck: Stru ttlral concrete to meet project requirements to satisfaction of Authority Having
Juri diction.
Primer: SoplIrema Elastocol 600c
Underlayment: Tri-IBuiltS/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Mk 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
re uirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: PI wood shall be thoroughly cleaned to remove dust and debris that may inhibit
a hesion. All sheathing fasteners shall be driven flush with the surface. All sharp
4inters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: �ri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
oller and/or weighted roller to ensure there are no voids, and ensure there are no
oids/bridging at side and end -laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: i Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
Iand tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-BuiltS/A HT TU Underlayment, self -adhered.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization N9503 67M EDITION (2017) FBC NON-IIVI-IZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/2S/2017
Page 4 of 6
t�` M TRINffY ERV
5.6.4.1 For mechanically attached Ba�e Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. .
Alternatively, the maximum Idesign pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designs by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods. are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 17. Assemblies marked with an asterisk` carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
5.8.
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 3t-days after installation
Tri-Built S/A HT TU Under, ayment shall not be left exposed for longer than 180-days after installation.
When loading roof tiles c n the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These sl Ipe limitations can only be exceeded by using battens during loading of the roof
tiles.
7. ?ABLE 2 I!E SLIPPAGE LIMITATIOyNS FOR DIRCrx DEGKTILE CNSTALLATIQN5 t tY i ,, , ,;,#„�s „
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max.10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
Tri-Built S/A HT TU
Underlayment
Lugged
r ��
Exterior Research and Design, LLC. I Evaluation Report A42960.10.12-R6
Certificate of Authorization N9503 I e" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 5 of 6
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlaym,
published installation requi
specifics noted below.
6.2 • Re -fasten any loose decking
to remove any dust and debt
6.3 Tri-Built Sand-R SA Shingle I
Underlayment;
6.3.1 Shall be installed in comp
1507.1.1 for the type of pre
6.3.2 Non -Tile applications:
While priming is optional, 1
cover is not slated for instal
Apply sheet parallel to the
ft of release film.
Adhere the exposed part to
Once the entire length of
membranetight. Firmlyroi
Horizontal seams should b
inches and staggered not le
TRI-BUILT Materials Group,
When installing at slopes
overlap area at the top of ti
For Valleys and Ridges: Cut I
over valley or ridge. Drape
each direction. Forvaileys�
6.3.3 Tile Applications (Tri-Built 5
Reference is made to FF
instructions noted above,
For foam-od the applicati(
fall outside the scope of F
Tile shall be loaded an
underlayment. See Tabh
staging.
7. BUILDING PERMIT REQUIREMENTS:
ERD
8
shall be installed in accordance with TRI=BUILT Materials Group, LLC
nts subject to the Limitations set forth in Section 5 herein and the
nels, and check for protruding nail heads. Sweep the substrate thoroughly
prior to application, and prime the.substrate (if applicable).
with the requirements for ASTM D1970 underlayment in FBC Table
roof covering to be installed.
UILT Materials Group, LLC recommends priming the deck if the final roof
n within 24 hours.
edge. Roll out approximately 10 ft of membrane and pee[ back the first 3
the substrate and unroll the remaining membrane as far as possible.
((membrane is in place, peel -off the release film diagonally while holding the
I broom or hand -press the membrane into place to achieve a bond.
minimum 3-inches, configured to shed water. Vertical seams should be 6-
s than 2-ft from vertical seams in the course below, sealed in accordance with
LLC requirements.
bone 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
ie sheet at 12-inch o:c.
underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
and press sheet into place, working from the center of the valley or ridge in
apply thesheet starting at the lowest point and work upward.
;A/TRI April 2012 (04-12) installation Manual and Table 1 herein, using the
s a guideline.
is, reference is made to Section 5.6.4 herein for wind resistance limitations that
SA/TRI April 2012 (04-12).
staged in a manner that prevents tile slippage and/or damage to the
2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314.) 57
Exterior Research and Design, LLC,
Certificate ojAuthoriration #9503
k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Evaluation Report A42960.10.12-R6
e' EDiTION (20171 FBC NON-1-MiZ EVALUATION FL16048-1116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 6 of 6