HomeMy WebLinkAboutEVALUATION REPORTSCANNED
By
5t Lucie P011W
QOTRIN'ITYIERb
EVALUATION REPORT
Rc
r—N !{�GRA. . 1289 NrE 9th
R • O, -O F= T I . E: Okeechobe
(602)
SCOPE:
This Evaluation Report is issued
construction materials in the Stat
P.E. for use of the product and
products described herein have
(HVHZ) sections noted herein.
DESCRIPTION: Entegra
LABELING: Labeling shall
herein.
CONTINUED COMPLI
referenced Quality
Acceptance of this
Product changes o
review of this. EvaL
ADVERTISEMENT: ThE
advertising literature
INSPECTION: UI
its distributors
This Evaluatin,
Prepared by:
EXTERIOR RESEARCH & DESIGN, I.I.C.MAR. 2 $ 2018
Certificate of Authorization #9503
6Nei� county, Permitting 353 CHRISTIAN STREET, UNIT#13
- OXFORD, CT 06478
(203) 262-9245
f Tile, LLC Evaluation Report E39310.11.11-1-R4
Benue FL7804-R10
FL34972 Date of Issuance:11/02/2011
3 Revision 4:10/17/2017
wider Rule 61G20-3 and the applicable rules and regulations governing the use of
e of Florida. The documentation submitted has been reviewed by Robert Nieminen,
�r the Florida Building Code and 'Florida Building Code, Residential Volume. The
been evaluated for compliance with the 6th Edition (2017) Florida Building Code
Roof Tiles (HVHZ jurisdictions)'
in accordance with the requirements the Accredited Quality Assurance Agency noted
NCErr` This Evaluation Report is' valid until such time as the named product(s) changes, the
%S rance documentation changes, or provisions of the.Code that relate to the product change.
valuation Report by the named client constitutes.agreement to notify Robert Nieminen, P.E. if the
/the referenced Quality Assurance documentation, changes. TrinityJERD requires.a complete
tion Report relative to updated Code requirements with each Code Cycle.
Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
If any portion of the Evaluation Report is displayed, then it shall be done in its eny
)tiret.
n request , a copy of this entire Evaluation Report shaffbe provided to the user by the manufaCtUrer or
nd shall be available for inspection at the job site at the request Of the Buildin OffIC
Report consists of Pages 1 through 8, g lal,
orized by Robea Nleminen, fleas an a%bonlcallysigned
eve been transmittedfofhe
Senamedcl%nt
nanai�CtU!%pB or
7gproducts for
3rocess of The
'cord for any
ess retained
i •� -
TRINITY I ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
\
Product Category:
Roofing
Sub -Category:
Roofing Tiles
Compliance Statement:
Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
static Uplift Resistance
TAS 102(A)
1995
\
3. REFERENCES.
Entity
Examination
Reference
Date
02/21/2012
ERD (TST6049)
TAS 101
P39740.02.12
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.05-14
07/07/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
12/17/2015
ATL (TST3782)
Physical Properties
RT1210.02-15
R 1210.03-15
12/17/2015
'
ATL (TS73782)
Physical Properties
RT1103.01-15
11/07/2015
11/07/2015
ATL (TST 3782)
Physical Properties
RT1\103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1 \ 3.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT11 3.04-15 .
11/07/2015
ATL (TST 3�$Z)
Physical Properties
RT110 .05-15
T11
11/27/2014
ATL (TST 3782)
Ph sisal Properties
y
•12
11/05/2015
02/2512016
Miami -Dade AR1SSI)
Hance
HVHZ Come 1ianGe
Comp
15-0721.04
16-0112.06
02/25/2016
Miami•DB�@`CER1592�
HVHZ
Dance
HVHZ Comp'iance
16-0112•07
02/25/2016
Current
wam;_Dade l CER1592�
HVHZ Comp
16-0112.08 Confirmation
Membership Confirm
Exp 11/02/2018
CER1592� Ua p1 101' 1021A1
Miam►•Dade (CER159Z1 HVHZ Comp �
( T PPS 1.
Service Confirms tion
Miam►-Dade
Roof Institute
1 AS 100,
Quality Assurance
P?,\ QwN9111)
Exterio'
certlfic'
4. PRODUCT DESCRIPTION:
4.1 1 TAC 117 Tvna
Bermuda Flat
Horizon Flat
TRINITY I ERD
Plantation Flat
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate of Authorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-RID
Entegra Roof Tiles Revision 4:10/17/2027
Page 3 of 8
V I RINIIY I ERD
4.2 I TAS 112, Type 1a (interlocking, high -profile)
4.3 1 TAS 112, Type 1b (interlocking, low -profile) ESTATE "S" and HACIENDA
4.3 1 TAS 112, Type 2a (non -interlocking, high -profile) GALENA SPANISH "S" and REGAL
17"
Galena Spanish "S"
10"
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503 6T"EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Regal
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 4 of 8
TRINITY I ERD
S. LIMITATIONS:
5.1 This is a building code evaluation.. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evlIaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in the roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shl II have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1: AERODYNAMIC MULTIPLIERS -% (FT3)
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
j 0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate "S"
0.267
0.289
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Regal
j 0.287
0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVITY - Mi (FT-LBF)
Roof Slope
(0)
Tile
2:12<0<3:12
3:12<0<4:12
'4:1250<5:12
5:12<0<6:12
6:12<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
1 5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
1 6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
1 6.55
5.56
1 6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
1 8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, LLC.
Certificate of Authorization #9503
i
6" EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 5 of 8
UTRINITYIERD
c
�, ,z
"TABLE 3AS ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-
MEGHANICALLYATTACHED•SYSTEMS
MF (FT=LBF)
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Nail
Two (2)
lod
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)1
10d'
Ring'
N/A
50.3'
65.51
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
1Installation with a 4-inch tile headlap and fasteners located min. 2Y/-inch from head of tile.
Nail
One
10d
Smooth or Screw
N/A
8.82
11.82
4.12
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1) 2
lod
Smooth or Screw
Eave
19.02
19.02
22.12
Nail
One
30d
Smooth or Screw
Field
24.32
24.32
24.22
Nail
Two-(2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
"S"
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate or Hacienda
Nail
Two'(2)
10d
Ring
N/A
27.8
37.4
28.8
Nail'
Two (2)'
10d'
Ring'
N/A
43.01
67.51
50.9'
Screw
One
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
1Installation with a 4-inch tile headlap and fasteners located min. 2Y2-inch from head of tile.
2 For one (1) fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge.
Nail
One (1)
10d
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One (1)
30d
Smooth or Screw
Field
23.1
23.1
19.0
Nail
One (1)
10d
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
10d
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "r Regal Galena
Spanish "S" or
o
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1 1
41.8
Nail
Two (2)
lod
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)'
10d'
Ring'
N/A
33.1'
48.1'
50.91
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
#8
N/A
N/A
43.2
43.2
29.8
1Installation with a 4-inch tile headlap and fasteners located min. 2Y2-inch from head of tile.
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate of Authorization #9503 16T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
Q"TRINITYIERD
TABLE 4: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF (FT-LBF)
MORTAR AND ADHESIVE -SET SYSTEMS
Note from Entegra Roof Tile, LLC: The performance data listed in Table 4 are based on the respective adhesive manufacturers' test
reports and Miami -Dade NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to provide these values for our inclusion
in this FBC HVHZ Evaluation Report. Please consult the individual adhesive manufacturer for information on product approvals,
limitations, revisions or other information for determining wind load and overturning moment performance.
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
"TILE BOND'""' by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat,
"Polyset° RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Flat or
Horizon
"Polyset° AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
Independent (medium paddy, ^30 g)
51
Independent (large paddy, —45 g)
92
"TILE BOND'"" by Dow Chemical
I
NOA 16-0222.01
Interdependent (2-paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate "S" or
Hacienda
"Polyset° AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
50
Independent (medium paddy, —30 g)
37
Independent (large paddy, —54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-pa8dy)
48
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"Polyset° RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
"S", Galena
Spanish "S"
or Regal
®
"Polyset AH-160' by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy, —30 g)
49
Independent (large paddy, —63 g)
94
Mortar
Various
Per RAS 120
25
LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in i ccordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
I
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
CH EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 7 of 8
TRINITY I ERD
and/or
Han on
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:'
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
i
9. MANUFACTURING PLANTS:
Plant
Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon.Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, LLC.
Certificate of Authorization #9503
6T" EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4: 10/17/2017
Page 8 of 8