HomeMy WebLinkAboutPRODUCT APPROVAL ROOF TILEFlorida Building Code OnIP- SCANNED i Page 1 of 2
.°. 2
BCIS Home I Log In User Registration j Hot Topics 1 Submit Surcharge j Stats & Facts Publications FBC Staff BCIS Site Map j Links Search I
Florida go
Product Approval
USER: Public User
7`raTts�l`�::
Product Approval Menu > Product or Application Search > Application List > Application Detail RECEIVED
•' FL # FL6332-R8
Y'1
Application Type Revision
Code Version 2017 APR 0 4 2018
Application Status Approved
ST. 6ucie County, Permitting
Comments
Archived
Product Manufacturer ICP Adhesives & Sealants, Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs, FL 33065
1 (888)774-1419 Ext201
f rylipelkonen@icpadhesives.com
Authorized Signature I Riku Ylipelkonen
rylipelkonen@icpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory IrII Roof Tile Adhesives
Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed
111 Florida Professional Engineer
' Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who' developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract ExpirationDate 02/07/2021
Validated By John W. Knezevich, PE
,,6 Validation Checklist; Hardcopy Received
Certificate of Independence FL6332 R8 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
SSTD 11 1997
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquanCtKft6P/o2fM%2b..'. 4/2/2018
Florida Building Code Online . I Page 2 of 2
Date Submitted
10/'12/2017
Date Validated
10/114/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
I
FL #
Model, Number or Name I
Description
6332.1
ICP Adhesives Polyset AH-160
Dual component expanding polyurethane roof file adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6332 R8 II 2017 SO FINAL ER ICP AH160 FL6332-
R8.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +n/a/-178
Created by Independent Third Party: Yes
Other: 1.) The design pressure limitation in this application
Evaluation Reports
refers to hip and ridge tiles in one configuration. Refer to
Table 2 of ER for all hip and ridge tile limitations. 21.) Field
FL6332 R8 AE 2017 10 FINAL ER ICP AH160 FL6332-
R8.Ddf
tiles are designed based on overturning moment resistance.
Created by Independent Third Party: Yes
Refer to Table 1 of ER for field tile limitations. 3.) Refer to
ER Sections 5 for other Limitations of Use. i
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for otficiallcommunioUon with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Prodr�ucctt Approval Accepts:
Credit Card
- -- -- - ---- - - -- --- - -Safe--- - - ---- --- ---------- -
I
I
i
I
I
a
I
https://floridabuilding.org/pr/pr�_app_dt I I.aspx?param7--wGEVXQwtDquanCtKft6fD/o2fN4%2b... 4/2/2018
QOTRINITYIERD
EVALUATION REPORT
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL 33065
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT 13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 02768.03.06-118
FL6332-R8
Date of Issuance:08/08/2008
(888) 774-1419 1 Revision 8:10/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 anId the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 61h Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid uIntil such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
-advertising literature. --If any portion of -the Evaluation Reportis displayed; then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9!
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/12/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
'mil TRINITY I ERD
ROOFING COMPONENT EVALUATION:
SCOPE: I
Product Category: Roofing
Sub -Category: Roof Tile Adhesives I
Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 6th Edition (2017)1 Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to�the Installation Requirements and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Sections Property
1504.2.1.1 Overturning resistance I
3. REFERENCES:
gniinl
Examination
ERD (TST 6049)
Static Uplift -SSTD 11 i
ERD (TST 6049)
Static Uplift - SSTD 11 ,
ICC-ES (EVL2396)
2012 IBC Compliance !
Miami -Dade (CER 1592)
HVHZ compliance
PRI (TST 5878)
Static Uplift-SSTD it
PRI (TST 5878)
Static Uplift-SSTD 11�
PRI (TST 5878)
Static Uplift-SSTD 111
PRI (TST 5878)
Static Uplift - SSTD 11
PRI (TST 5878)
Static Uplift - SSTD 11
PRI (TST 5878)
Static Uplift - SSTD it
_ PRI (TST 58.7-8) _ _
---Static-Uplift.—SSTD-1-11-
PRI (TST 5878)
Static Uplift -SSTD 11
PRI (TST 5878)
Static Uplift - SSTD 11
PRI (TST 5878)
Static Uplift - SSTD it
PRI (TST 5878)
Static Uplift -SSTD 11
PRI (TST 5878)
Static Uplift - SSTD it
PRI (TST 5878)
Static Uplift -SSTD ,11
PRI (TST 5878)
Static Uplift - SSTD,11
PRI (TST 5878)
Static Uplift -SSTD it
PRI (TST5878)
Static Uplift-SSTD 11
PRI (TST 5878)
Static Uplift -SSTD 11
PRI (TST 5878)
Static Uplift - SSTD it
PRI (TST 5878)
Static Uplift -SSTD 11
UL LLC (QUA 9625)
Quality Assurance
5
Standard Year
SSTD 11 1997
Reference
Date
P39740.02.12
02/20/2012
P39740.11.13-R1
01/02/2015
ESR-1709
12/01/2016
17-0322.03
04/27/2017
ECM-001-02-01
09/21/2001
PFI-006-02-01
05/09/2005
PFI-006-02-02
05/09/2005
PFI-007-02-01
10/11/2005
PFI-008-02-04
02/21/2006
PFI-009-02-03
02/21/2006
TGRI=001-02--03 -- -- --
------ 10/30/2006 — -- --- -- - - --- ---
TGRI-001-02-03
10/30/2006
PFPI-010-02-01
12/07/2006
PFPI-011-02-01
12/07/2006
PFPI-012-02-01
12/07/2006
PFPI-013-02-01
12/07/2006
PFPI-014-02-01
12/07/2006
ECM-003-02-01
06/13/2008
ECM-004-02-01
06/13/2008
ECM-005-02-01
06/13/2008
ECM-006-02-01
06/13/2008
ECM-007-02-01
06/13/2008
ECM-008-02-01
06/13/2008
Service Confirmation
Exp. 06/05/2018
PRODUCT DESCRIPTION:
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders (ICP Adhesives ProPack® 30 & 100).
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, LLC: Evaluation Report 02768.03.06-R8
Certificate afAutharizotion #9503 a EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 2 of 9
5.3 Fire classification is not part of this evaluation.
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset® AH-160 can be used wi
assembly having a current Florida Statewide P
Having Jurisdiction.
5.5 Minimum underlayment shall be per FRSA/T
Product Approval or approved on a local -level I
Polyset® AH-160. 1
5.6 Field tiles, meeting the limitations of FBC 1
projects having an Aerodynamic Uplift Momen
2A and 2B of FRSA/TRI April 2012 (04-12), n
values. Refer to Section 10 and ICP Adhesi
Adhesive Paddy Placement details.
\1 TRINITY I ERD
to a current Roofing Materials Directory for fire ratings
flat, low and high profile tiles or any rigid, discontinuous roof
duct Approval or approved on a local -level by the Authority
April 2012 (04-12) or having a current Florida Statewide
the Authority Having Jurisdiction for use with ICP Adhesives
609.5.3, using ICP Adhesives Polyset° AH-160 are limited to
t (Ma), determined in accordance with FBC 1609.5.3 or Tables
of greater than the following Allowable Overturning Moment
ves and Sealants, Inc. published installation instructions for
TABLE 1:, FIELD,TILES IN ICP ADHESIVES POLYsET AH-160
ALLOWABLE OVERTURNING MOMENT P.,ERF,ORMANCE DATA
` - 2T03rMARGINOFSAFETY,ALREADYAPPUEDFOR INDEPENDENT (SINGLEORCONi1N000SPADDY)PLACEMENT
- '• ,', 4TOIMARGINOFSAFETYALREADYAPPOEDFORINTERDEPENDENT(TWOPADDY) PLACEMENT '
Tile (FBC 1609.5.3)
!
Adhesive Paddy Placement
Allowable
Overturning
Type
Profile
Moment (ft-Ibf)
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
60
Clay
Flat
Independent; Single Paddy, Large (2x10-inch, -45 gram)
112
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap)
54
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
39
Clay or
_Concrete_.
Low/
_Medium____
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
—
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap)
_
58
Clay
High
Independent; Single Paddy, Large (2x10-inch, -45 gram)
134
Clay
Independent; Single Paddy, Medium (2x7-inch, -30 gram)
65
Independent; Single Paddy, Large (2x10-inch, -63 gram)
109
Concrete
High
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile overlap)
40
Clay
Barrel
2x10-inch x -35 gram for pans; 2 @ 1x10-inch x -17 gram for cap
147
Concrete
Barrel
2x10-inch x -35 gram for pans; 2 @ 1x10-inch x -17 gram for cap
107
ClayCap
atop 2x
Independent: Continuous Paddy
p y ("34 gram/ft)
135
stringer
Concrete
Cap atop 2x
stringer
Independent: Continuous Paddy
p y (" 34 gram/ft)
116
Clay
Cap atop 2x
Interdependent:
stringer
Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram)
105
Concrete
Cap atop 2x
Interdependent:
76
stringer
Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram)
b.b.1 uata in I able 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Polyset° AH-160.
5.6.2 Tile roof systems using tile types or' profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent ,two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8
Certificate of Authorization #9503 6T'EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017
Page 3 of 9
TRINITY J ERD
5.7 Hip and ridge tiles using ICP Adhesives Polyset° AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddy Placement details.
TABLE.2:: HIP &-RIDGE TILES IN ICP ADHESIVES POLYSET® AH 160
-..
L-.
ALLCIWABLE UPLIFT RESISTANCE PERFORMANCE DATA
Z T01 MARGIN OF SAFE7YALREADYAPPLIED FOR INDEPENDENT, CONTINUOUS PADDY PLACEMENT
.. • .4T-01 MARGIN OF SAFETYALREADY, APPLIED FOR INTERDEPENDENT PLACEMENT
..
I
Allowable
Tile
Substrate
Attachment Method
1 Design Pressure
I
(Psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (-34 gram/ft)
116
Concrete
2x PT ridge board i
Independent: Continuous Paddy (- 34 gram/ft)
107
Clay
2x PT ridge board
Interdependent: Head: One (1) #10 x 2Y2" screw;
90
Overlap: 1 x 6 inch ("10.5 gram)
Concrete
2x PT ridge board
Interdependent: Head: One (1) #10 x 2%" screw;
56
Overlap: 1 x 6 inch (-10.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Concrete
galvanized only
Independent: Continuous Paddy (-34 gram/ft)
169
Clay or
Trim Lock'" (FL5374): aluminum,
Concrete
galvanized, Galvalume® or stainless steel
Continuous Paddy Independent:
p y ("34 gram/ft)
173
Clay or
Trim LockTM Plus (FL5374): aluminum,
Concrete
galvanized, Galvalume® or stainlessstee!
Continuous Paddy Independent:
p Y (" 34 gram/ft)
178
Clay
Top Notch (FL8095)
Independent: Continuous Paddy 32 gram/ft)
125
Concrete
Top Notch (FL8095) _ _ __
Independent: Continuous Pad _(^ 32 gram/ft)_-_
_ 146
6. INSTALLATION:
6.1 ICP�;Adhesives Piol set® AH`160and,;the tile roof assembly shall be installed in accordance with FRSA/TRI
Aprils2012: (04=12)"and'ICP`Adliesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
8. MANUFACTURING PLANTS:
Tomball, TX
QUALITY ASSURANCE ENTITY:
UL, LLC. - QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com
Exterior Research and Design, LLC. Evaluation Report 02768.03.06-118
Certificate ajAuthorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 4 of 9
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES
10.1 Independent, Medium Paddy:
Nail through plastic cement Paddy (Beneath Tile)
(when required)
Underlayment
o
f
z-"2
Eave Closure
Exterior Research and Design, U.C.
Certificate ofAuthoriration #9503
Nallthiough plastic
(when required)
nderiayment__
� e
TRINITY ERD
INC. PUBLISHED LITERATURE):
Nall through plastic cement
(when required)
Underlayment
r
7 in.
2 in.
Battens optiona I
•4h _^
10in
ti
Medium Profile Tile
/ Paddy (BeneatIT11e)
7 in'
Battens optional
r Eave Cour sel �J
Fasci
Weephole
1 o in. 2 in, Eave closure
Drip edge
High Profile Tile
e EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH-160; (888) 774-1419
I
I
I
(Beneath Tile)
'I— Eave Closure
Fascia
Evaluation Report 02768.03.06-R8
FL6332-R8
Revision 8:10/12/2017
Page 5 of 9
10.2 Independent, Large Paddy:
Nail through plastic cement Paddy (Beneath Tile)
(when required)
Underlayment °c
10 in�_
Battens optional °
Eave Course
°
2i
Eave Closure
STRINITY ERD
Nail through plastic cement
(when required)
Paddy (Beneath Tile)
t
Underlayment
loin.x
2 in.wide
Battens optional
_
loin .
Eave Closure
Eave Course
Fascia
— M- u: ;�• .rr. Nail1hr"o6gh plasticce
(when required_) C
Underlayment \
10 in.x
2 in. wide
i
Battens o
optional �^
Eave Course ~'
� 10 in. �2 in.
High Profile Tile
Medium Profile Tile
Paddy (Beneath Tile)
Weephole
Eave closure
Drip edge
Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118
certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVH2 EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (988) 774-1419 Revision 8:10/12/2017
Page 6 of 9
10.3 Interdependent. Two Paddv:
Nail through plastic cement Paddy (between tiles)
(when required)
Battens optional °
° Paddy (under tile)
Single paddy
r on top of the „'�
x4in.
gent 1 !` 2 x 4 in.
°r
}
loin.
Eave Closure
<<F(at/Low;`?,rofile Tile
Nail through plastic
(when required)
Battens
optional
Nail through plastic cement
(when required)
�\Itf�RINITYJ ERD
paddy under tile
Paddy (between tiles)
/Paddy (under tile)
Single paddy
on top of tile,
x4in. x4in
dy on
lent z�
loin v 2in.
I
Marlhim DrnfilaTila
le paddy undertile
I
Paddy(between tiles)
I
Paddy (under tile)
��o-n underlayment 9 \
�'4 x 4 in.
n.
Singly 2x4i��
paddy on
top of tile
i
Eave Course Fasci
i
Weephole
loin. .2 in. Eave closure
�. Drip edge
High Profile Tile
Exterior Research and Design, U.C.
Certificate oJAuthorization #950.3 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH-160; (888) 774-1419
I
",-- Eave Closure I
Fascia
Evaluation Report 02768.03.06-R8
FL6332-R8
Revision 8;10/12/2017
Page 7 of 9
I
TRINITY i ERD
10.4 Two Piece Barrel (Cap & Pan) Tile:
I
1) Place enough adhesive to achieve 651to 70 sq.in. Steep pitch applications
In contact with the pan tile. I k (when required)
2) Tom Covers upside down. Place adhesive
112 In. to 1 inch in (turn outside edge of cover tile.
Install cover tile.
Ensure 20 to 25 sq. in. contact area a --
each side of cover tile.
uncierlayment
r o
Eave closure i:—
(motar shown)
Weephole
Fascia Board
Remove top portion of the eave course Clover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
A bead ofICP PolyS AH-I60 maybe applied above the Geld
tile surface oo both sides of the hip edge board or gahsixed
metal frame to provide uvatlmbiodcne.
Exterior Research and Design, U.C.
Certificate oJAuthori2ation #9503
Two Piece Barrel I L High Profile Tile
I
6v1 EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH460; (888) 774-1419
Evaluation Report 02768.03.06-RS
FL6332-R8
Revision 8: 10/12/2017
Page 8 of 9
10.6
H
- END OF EVALUATION REPORT -
\,l TRINITYIERD
Exterior Research and Design,LLC. Evaluation Report 02768.03.06-RH
Certificate ofAuthori:ation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017