Loading...
HomeMy WebLinkAboutDOOR-WINDOW SCHEDULESWINDOW SCHEDULE MARK OPERATION TYPE MATL SIZE REMARKS WIDTH HEIGHT SILL HT. 1> - FIXED E S L 3 6'-0" 3'-011 4'-1" N.D.A. #07-0411.11. CLEAR WIRE 3/4 FIRE TED LABEL B FIXED E STEEL 6'-0" 3' 0" 4'-1" N.D.A. Ri #07-0411.11. CLEAR WIRE 1/4 FIRE TED LABEL B ROOM FINISH SCHEDULE WALL FINISH CEILING REMARKS ROOM NO. ROOM NAME FLOOR BASE NORTH SOUTH EAST WEST MATERIAL FINISH HT. O1 CONTROL ROOM VCT VINYL GWB/PAINT GWB/PAINT GWB/PAINT GWB/PAINT GWB PNT 1 2 O2 I QUALITY CONTROL ROOM VCT VINYL GWB/PAINT GWB/PAINT GWB/PAINT GWB/PAINT GWB PNT 1 2 O3 RESTROOM TILE TILE CT/GWB/PNT CT/GWB/PNT CT/GWB/PNT CT/GWB/PNT GWB PNT 1 2, MOISTURE RESISTANT GWB O4 I RESTROOM TILE TILE CT/GWB/PNT CT/GWB/PNT CT/GWB/PNT CT/GWB/PNT GWB PNT 1 2, MOISTURE RESISTANT GWB 05 INSTRUMENT STORAGE VCT VINYL GWB/PAINT GWB/PAINT GWB/PAINT GWB/PAINT GWB PNT 1 2 O6 I DRY ANALITICAL INST. STOR. VCT VINYL GWB/PAINT GWB/PAINT GWB/PAINT GWB/PAINT GWB PNT 1 2 67 MAIN ELECTRICAL ROOM SEALED CONCRETE UNF/PAINT UNF/PAINT UNF/PAINT UNF/PAINT EXP PNT 1 2 Q$ RECTIFIER ROOM SEALED - UNF/PAINT UNFIPAINT UNF/PAINT UNF/PAINT EXP PNT 1 2 CONCRETE Q9 TRANSFORMER AREA SEALED UNF/PAINT UNF/PAINT UNF/PAINT UNF/PAINT EXP PNT 1 2 CONCRETE 1 O PLANT AREA SEALED UNF/PAINT UNF/PAINT UNF/PAINT UNF/PAINT EXP PNT 1 WATERPROOF CONIC. SLAB CONCRETE 11 MAIN ELECTRICAL ROOM VCT VINYL UNF/PAINT UNF/PAINT UNF/PAINT UNF/PAINT EXP PNT 1 2 12 CELL MAINTANECE ROOM SEALED CONCRETE UNF/PAINT UNF/PAINT UNF/PAINT UNF/PAINT EXP PNT 1 2 NOTE: 1. SEE REFLECTED CEILING PLAN FOR HIGH ELEVATION 2. COLOR TO BE SELECTED BY OWNER WINDOWS AND DOORS NOTES 1. SEAL TIGHT WITH BACKER ROD AND SEALANT AT ALL JOINTS BETWEEN DOORS, WINDOWS, AND LOUVERS AT MASONRY OR ROUGH OPENINGS. APPLY SEALANT @ EXTERIOR CONDITIONS, AND ACOUSTICAL SEALANT AT INTERIOR CONDITIONS. 2. DIMENSIONS SHOWN ON PLANS, ELEVATIONS OR SECTIONS DENOTE MASONRY OR ROUGH OPENINGS UNLESS OTHERWISE NOTED. GENERAL CONTRACTOR Al SUBCONTRACTORS SHALL VERIFY DIMENSIONS AT JOB SITE AND SHALL CONTACT ARCHITECT, IF ANY DISCREPANCIES ARE FOUND, BEFORE PROCEEDING WITH WORK. 3. WINDOW, DOOR AND LOUVER MANUFACTURERS SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. ANY REVISION OR CHANGE IN MATERIALS, USE OR MANUFACTURE OF THE PRODUCT SHALL AUTOMATICALLY BE CAUSE FOR TERMINATION, UNLESS PRIOR APPROVAL IS GRANTED FOR REVISION OR CHANGE. ALL UNITS MUST BE LABELED, GIVING THE MANUFACTURER'S NAME, MIAMI-DADE COUNTY PRODUCT CONTROL APPROVAL NUMBER, APPROVED ELEVATION AND DATE OF EXPIRATION. 4. ALL EXTERIOR WINDOWS, LOUVERS AND DOORS SHALL BE DESIGNED TO WITHSTAND WIND LOADS AND MEET THE REQUIREMENTS OF SECTION 6 OF STANDARD 7-97 OF THE AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-93) AS PER FLORIDA BUILDING CODE,HIGH VELOCITY HURRICANE ZONES, BASED UPON THE DESIGN WIND LOAD PRESSURE CALCULATIONS FOR EACH EXTERIOR OPENING WINDOW. 5. ALL WINDOWS, SLIDING DOORS, AND LOUVERS SHALL BE EQUIPPED WITH INSECT SCREENS (U.O.N.) 6. ALL EXTERIOR AND INTERIOR ALUMINUM FRAMING SHALL BE 1 1/2" X 4" WITH CLEAR ANODIZED FINISH UNLESS OTHERWISE NOTED. 7. ALL EXTERIOR WINDOWS SCHEDULED SHALL RECEIVE 3/16" LAMINATED IMPACT RESISTANT GLASS, TINTED. TINT COLOR TBS BY ARCHITECT. 8. NOT USED. 9. ALL PUSH PLATES, PULL HANDLES, AND/OR PROTECTIVE BARS ON DOORS OR FIXED GLASS PANELS SHALL BE STAINLESS STEEL SATIN FINISH UNLESS OTHERWISE NOTED. 10. ALL ALUMINUM BRAKE METAL (CLOSURES) SHALL BE 0.40 ALUMINUM (MIN) GLUED WITH SILICONE AND FASTENED TO STEEL COLUMNS AS REQUIRED, AND/OR ANY OTHER METAL FRAME ON WINDOWS & DOORS, CLEAR ANODIZED FINISH. COLOR T.B.S. BY OWNER/ARCHITECT. 11. ALL ALUMINUM EXTERIOR AND INTERIOR STOREFRONTS, WINDOWS, DOORS AND FIXED GLASS SHALL BE MANUFACTURED BY R.C. ALUMINUM OR APPROVED EQUAL. INSTALLATION SHALL BE CONDUCTED IN A WORKMANLIKE MANNER AND AS PER MANUFACTURER INSTRUCTIONS. 12. HARDWARE FOR ALL WINDOWS AND DOORS SHALL CONFORM TO SECURITY AND FORCED ENTRY PREVENTION REQUIREMENTS OF FBC (SEE THE INTRUSION AND BURGLARY NOTES). 13. ALL WINDOWS & EXT. DOORS FASTENERS SHALL BE TAPCON ANCHOR DRIVEN SCREWS. THE SPACING OF FASTENERS SHALL BE AS TESTED OR MIN. 24" O.C. AT CONCRETE COLUMNS CONDITIONS OR 15" O.C. AT CONCRETE BLOCK FILLED CELLS, AND THE FIRST FASTENER SHALL BE LOCATED A MAXIMUM OF 4" FROM EACH CORNER AND MULLION OR STILE. MINIMUM PENETRATION OF FASTENER SHALL BE AS TESTED OR 1 3/4'. MIN, WHICHEVER IS GREATER. NO WOOD OR PLASTIC SHIELDS OR PINS SHALL BE USED. 14. ALL WINDOW AND SLIDING DOOR WOOD BUCKS SHALL BE A 1X4 P. T. WOOD MIN. (RECTANGULAR SHAPE), BUT WHERE WINDOW OR SLIDING DOOR JAMB IS GREATER THAN 4" ALL WOOD BUCKS SHALL HAVE A MIN. DEPTH EQUIVALENT TO THE DEPTH OF THE WINDOW OR THE SLIDING DOOR. 15. NOT USED. 16. ALL WINDOWS, LOUVER AND DOOR INSTALLATIONS ARE TO BE IN A SEPARATE BUILDING PERMIT. MANUFACTURERS/INSTALLERS SHALL SUBMIT SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL. 1. STANDARDS: (a) BURGLAR -RESISTANT GLASS SHALL CO PLY WITH ASTM C1036 FOR POLISHED PLATE GLASS o -u -- - t 4'-0" A IB' C� iD; EI F'i FLUSH NARROW LITE DOUBLE ROOL-UP DOUBLE FULL LOUVERED DOORS FLUSH OVERHEAD FLUSH 1 DOOR TYPE A-7 0 4' 8' 16' SCALE: 1/4" = V-0" O ,�10Rv- �`QROo R GS�NP"; PN° Nv j01 ZNEs� es E g� O O \ v �N 0�0� oi�G00�5 00�\RHO NEG�S�P PIN. G00p0 (b) TESTS OF BURGLAR -RESISTANT GLAZIN MATERIALS SHALL COMPLY WITH UNDERWRITER'S LPBORATORIES STANDARD FOR SAFETY OF BURGLAR RESISTANT GLAZING MATERIALS, UL72. (c) GLASS AND GLASS -LIKE MATERIALS SHA L COMPLY WITH THE AMERICAN NATIONAL STANDAF IDS INSTITUTE (ANSI) STANDARD FOR TRANSPARENT SAFETY GLAZING MATERIAL USED IN BUILDING, Z97.1. (d) ALUMINUM WINDOWS SHALL COMPLY WITH THE ARCHITECTURAL ALUMINUM MANUFACTURER'S ASSOCIATION (AAMA) STANDARD FOR FORCED -ENTRY RESISTANT HORIZONTAL SLIDING WINDOWS, AAMA 1302.5, AND ANSI/AAMA 101. 2. ALL EXTERIOR DOORS SHALL BE PROVIDED WITH CYLINDRICAL TYPE LOCKS SETS, LATCH BOLT BY KNOBS, LATCH BOLT DEAD -LOCKED WHEN DOOR CLOSED, KEY OPERATED FROM OUTSIDE WITH PRIVACY TURN BUTTON FOR LOCKING OUTER KNOB WHICH IS NOT AUTOMATICALLY RELEASED, ACCORDING TO FED. SPEC. #160 AND #16 CAPABLE OF RESISTING A FORCE OF 300 LBS IN ANY MOVABLE DIRECTION. MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH DEAD BOLT KEY OPERATED FROM OUTSIDE AND BY TURN LEVER FROM INSIDE. OTHER EXTERIOR DOORS TO BE PROVIDED WITH INTE RIOR SINGLE DEAD BOLT. ALL TO BE 1" MIN. THRUST AND OF HARDENED OR CONTAIN INSERTS. AT DOUBLE DOORS SECOND DOOR SHALL BE PROVIDED WITH HAND BOLTS TOP AND BOTTOM. DOORS TO BE MOUNTED ON 3- 3 1/2" PAIR OF HINGES WITH NON -EXPOSED SCREWS AND NON -REMOVABLE PINS BY SET SCREWS IN BARREL. MAIN ENTRANCE DOORS TO HAVE DOOR SCOPE PERMITTING INSIDE VIEWER A 1800 OBSERVATION ANGLE OF OUTSIDE WHEN DOOR CLOSED (UNLESS OTHERWISE NOTED). 3. HINGES ON EXTERIOR OUT SWINGING DOC IRS SHALL HAVE NON -REMOVABLE PINS. 4. GLASS IN EXTERIOR DOORS AND ALL GLAZING WITHIN 48" OF INSIDE LOCKING DEVICE OF DOOR SHALL COMPLY WITH A.N.S.I. 297.1. 5. INTERIOR DOORS TO HAVE CYLINDRICAL PE LOCK SETS WITH PRIVACY LOCK BY INSIDE PUSH BOTTOM WHICH AUTOMATICALLY OPENS BY TURN OR BY CLOc1NG ACCORDING TO FED. SPEC. #160 AND 161 L (UNLESS OTHERWISE NOTED). 6. ALL WINDOWS, AWNING, SINGLE HUNG OR IORIZONTAL SLIDING SHALL BE PROVIDED WITH A LOCKING DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 -BS. APPLIED IN ANY OPERABLE DIRECTIONS, OR AS SPECIFIED IN THE PAN AMERICAN FORCE AWNING TYPE 49 89 F. WINDOW FRAMES SHALL BE CONSTRUCTED SO THAT WHEN FIXED OR LOCKED THEY CANNOT BE REMOVED FROM THE OUTSIDE. 7. LOCKS ON EXTERIOR DOORS SHALL BE A INIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS S.F.B.C. CHAPTER 36, ITEM 36 .2(A)(2). 8. ALL EXTERIOR DOORS & WINDOWS SHALL E IN COMPLIANCE WITH THE FLORIDA BUILDING CODE. 6'-0" o� E;I FIXED LITE (WINDOW) DOOR SCHEDULE DOOR No. DOOR FRAME LABEL FIRE RATED HARDWARE SET No. REMARKS SIZE TYP MATL FIN DETAIL TYPE MATL FIN WIDTH HEIGHT THK HEAD JAMB THR 1 3'4" 7'-0" 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 4 7/A-5.01 - MTL. PNT. C 45 MIN 2 3'-0" 7'-0" 13/4" A WD PNT. 3/A-5.01 3/A-5.01 7/A-5.01 - MTL. PNT. _ _ 3 T-0" 7'-011 13/4" A WD PNT. 3/A-5.01 3/A-5.01 - MTL. PNT. _ 4 T-O" T-0" 13/4" A WD PNT. 3/A-5.01 3/A-5.01 - MTL. PNT. 5 3'-011 7'-011 13/4" B WD PNT. 3/A-5.01 3/A-5.01 7/A-5.01 - MTL. PNT. _ 4 6 T-O" 7'-011 1 3/4" B HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. C 45 MIN WIRE CLEAR GLASS 7 T-0" 7'-0" 13/4" B WD PNT. 3/A-5.01 3/A-5.01 7/A-5.01 - MTL. PNT. 8' T-O" 7'-011 13/4" A WD PNT. 3/A-5.01 3/A-5.01 - - MTL. PNT. 9' 3'-011 7'-011 13/4" A WD PNT. 3/A-5.01 3/A-5.01 - - MTL. PNT. _ _ a 10 8'-01' 11'-0" - D MTL PNT. 6/A-5.01 5/A-5.01 - MTL. PNT. B 1 1/2 HR (11 8'-011 11'-0" - D MTL PNT. 6/A-5.01 5/A-5.01 MTL. PNT. B 1 1/2 HR 12 3'-011 7'-011 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. B 1 1/2 HR 13 NOT USED - 14 3'-011 7'-0" 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. A 3 HR 15 16'-011 12'-611 _ E CL GSTL - , I - - - - :16 16'-011 12'-6" - E CL GSTL- 117 11'-011 11'-01, D HM PNT. 6/A-5.01 5/A-5.01 - MTL. PNT. A 3 HR 18 3'-0" 7'-0" 1 3/4" A HM PNT. 3/A-5.01 3/A-5.01 - - MTL. PNT. A 3 HR 19 (2)3-4' 7'-011 1 3/4" C HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. C 45 MIN 20 " ' 2 3-0 ( ) 7-0" ' 1 3/4" E HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. s-, , ) 4 IF, y PANIC HARDWARE 21 (2) T-0" 7'-011 1 3/4" E HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. _ '_ nil ANIC HARDWARE 22 18' 0" 16'-0" D GSTL GSTL 6/A-5.01 5/A-5.01 - - MTL. PNT. _ 23 3' 0" 8' 0" 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. 24' 3'-011 7'-011 1 3/4" B HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. > B 1 1/2 HR 25 3'-011 7'4" 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. > C 45 MIN 26 12'-011 11' 0" - D MTL PNT. 6/A-5.01 5/A-5.01 - - MTL. PNT. C 45 MIN P7 12'-0" 11'-0" - D MTL PNT. 6/A-5.01 5/A-5.01 - - MTL. PNT. C 45 MIN 28 3'-011 T-0" 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. > C 45 MIN 29 3'-011 7'-011 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. > C 45 MIN 30 T-0" 7'-011 1 3/4" A HM PNT. 2/A-5.01 2/A-5.01 - - MTL. PNT. > C 45 MIN 31 2'-011 T-0" 13/4" A WD PNT. 3/A-5.01 3/A-5.01 7/A-5.01 - MTL. PNT. _ _ 32; 16'-011 16'-011 - D GSTL GSTL 6/A-5.01 5/A-5.01 - - MTL. PNT. _ _ i33 (2) 3-0n 7-0r n 1 3/4n E HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 MTL. PNT. _ _ PANIC HARDWARE 34 8'-011 11'-01, - D GSTL GSTL 6/A-5.01 5/A-5.01 - - MTL. PNT. _ _ PANIC HARDWARE 35 $1_011 11'-0" - D GSTL GSTL 6/A-5.01 5/A-5.01 - - MTL. PNT. _ _ PANIC HARDWARE sI 4'-011 8'-011 13/4" E HM PNT. 2/A-5.01 2/A-5.01 - _ MTL. PNT. _ A 37 8'-0" 8'-01, 13/4" E HM PNT. 2/A-5.01 2/A-5.01 - _ MTL. PNT. _ _ AB HM PNT. 2/A-5.01 2/A-5.01 7/A-5.01 - MTL. PNT. B 1 1/2 HR 39 S-0" 7'4" 1 3/4" A HM I PNT. I 2/A-5.01 I 2/A-5. 1 /A-5.01 - MTL. PNT. B 1 1/2 HR DOOR SCHEDULE ABBREVIATIONS ALU ALUMINUM GSTL ANOD ANODIZED MRBL CL CHAINLINK PNT HC HOLLOW CORE SC HM HOLLOW METAL ST GALV GALVANIZED STN WD LABEL "A" DOORS 3HR FIRE RATED LABEL "B" DOORS 1-1/2 HR FIRE RATED Q LABEL "C" DOORS 45 MIN. FIRE RATED GALVANIZED STEEL MARBLE PAINTED SOLID CORE STEEL STAINED WOOD NOTES: 1. ALL DOORS ARE TO BE LOCATED 4" FROM WALL UNLESS LOCATION IS INDICATED IN THE FLOOR PLAN. 2. INSTALL DOORS AS PER MANUFACTURER'S RECOMMENDATIONS. 3. HARDWARE: A.THE HARDWARE WILL CORRESPOND WITH FIRE REQUIREMENTS B. FINISH WILL BE SATIN CHROMIUM PLATED C. CLOSERS ARE REQUIRED AT ALL FIRE DOORS D. SPECIFIC DESIGN TO BE SELECTED BY OWNER ARCHITECT E. ADA COMPLIANT F. COORDINATE W/ SECURITY SYSTEMS DESIGNER/INSTALLER DoNoB Design Group, LLC AA26001282 5835 Blue Lagoon Dr. Suite 200 Miami, Florida 33126 Tel. 786.275.8480 Fax 786.275.8474 www.dnbdesigngroup.com ALLIED NEW TECHNOLOGIES PLANT "MAIN BUILDING" FT. PIERCE, FLORIDA OWNER ALLIED UNIVERSAL CORP. 3901 NW 1 15th AVE DORAL, FL 33178 305.888.2623 DNB PROJECT NUMBER 07-120a OWNER'S PROJECT NUMBER ISSUED FOR: CONFORM SET TYPE OF DOCS: CONSTRUCTION DOCUMENTS ==�M DRAWN BY: APPROVED BY: R.B. F.D. DATE: SCALE: 01.31.08 AS SHOWN CONSULTANTS: Conve & AVS Inc. `Z? 10691 North Kendall Drive, Suite 3039 Mlaml, Flmid., 33176-USA L b r.. - , 1 1 J_. oF. II c .;,, ,,, 1p- Adolfo J. Gonzalez, P.E. STATE OF FLORIDA STRUCTURAL ENGINEER No. 58620 2050 Coral Way. Suite 400 Miami, Florida 33145 Phone: (305) 856-8935 Fax:(305) 856-8936 �Iq A933 J. DOM ND, R.A. This drawing is the property of DNB Design Group and is not to be reproduced or copied in whole or part. It is not to be used on any other project and is to be returned on request. COPYRIGHT © 2006 SHEET TITLE DOOR/ WINDOW & ROOM SCHEDULES SHEET NUMBER A-6.01