Loading...
HomeMy WebLinkAboutREVISION (2)FLOOR PLAN NOTES: 1- BASED ON SUBSURFACE EXPLORATION REPORT OF PROFESSIONAL SERVICE INDUSTRIES. Inc. (PSI) PROPOSAL No. 379-650129 OF SEPTEMBER 21, 2006. THE FOUNDATION HAVE DESIGN FOR A 2500 PSF SOIL BEARING CAPACITY. 2- TOP OF FOOTING ELEVATION (SEE FOOTING SCHEDULE ON S-5) 3- PROVIDE 35 x 6'-0" CORNERS BARS AT ALL FOOTING INTERSEPTIONS, EXTEND 3'-0' INTO EACH FOOTING. 4- TOP OF SLAB ELEVATION ENGINEERING 0'-0" EQUALS + ? N.G.V.D. 5-EXISTING DESIGN LIVE LOAD: 100 PSF. 6- REFER TO ARCH DRAWINGS FOR ADDITIONAL TOP OF SLAB, ELEVATION "Z", AND X-Y COORDINATES. 7- SEVERAL MASONRY BLOCK WALLS SHALL BE REINFORCED WITH 8- PROVIDE 2 #5 VET. (MINIMUM EACH S DEOOFPALLL DOORS AND WINDOWS (TYP. UNLESS OTHERWISE NOTED) 9- SEE S-4 FOR GENERAL NOTES AND S-5 FOR SCHEDULES. 10- ALL STEEL TO STEEL CONNECTIONS SHOWN OR NOT SHOWN SHALL BE STANDARD STEEL CONNECTIONS, SUBMIT SHOP DRAWINGS FOR APPROVAL. r------- - F-1 I I I I I P-1 I (:)j I I 00 I I I I I I I . I �I� I vl_ P-1 I I I I 1 I 0 0 N 00 v I F-1 L------ 11- SUBMIT SHOP DRAWIGS FOR ALL RAILINGS FOR APPROVAL PRIOR TO FABRICATION, SIGN AND SEALED BY A FLORIDA P.E. 12- CONTRACTOR MUST VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES. 13- CONTRACTOR MUST COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD, INCLUDING ALL WINDOW AND DOOR MASONRY OPENINGS. 14- CONTRACTOR MUST SUBMIT STRUCTURAL STEEL SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 15- PREFABRICATED STEEL STAIRS, CONTRACTOR MUST SUBMIT SIGN AND SEALED SHOP DRAWINGS AND CALCULATIONS BY A FLA. P.E., FOR APPROVAL PRIOR TO FABRICATION. -11" 24'-0" 23'-11" 24'-0" LEGEND: M INDICATES PREFABRICATED STEEL COLUMNS INDICATES CONCRETE COLUMNS ( COLUMN SCHEDULE ON S-5) OTI16II B"x8"x16" CONCRETE MASONRY UNITS WITH NO. 9 GAUGE Z �� LADDER TYPE JOINT REINFORCEMENT EVERY OTHER MENNEN COURSE (16" ON CENTER VERTICALLY) AND 1-#5 REINF. BAR GRADE 60 IN GROUT FILLED CELL AT ALL CORNERS, NEXT TO ALL OPENINGS, AND 32"o.c. OR UNLESS NOTED OTHERWISE. APPLICABLE CODES 1. FLORIDA BUILDING CODE 2004 EDITION. 8. A.S.T.M. STANDARDS AND SPECIFICATIONS. AMERICAN SOCIETY FOR 2. A.C.I. 318-02 FOR REINFORCED CONCRETE. TESTING AND MATERIALS. 3. A.C.I. 315-02 DETAILS AND DETAILING OF CONCRETE 9• AMERICAN FOREST AND PAPER ASSOCIATION: NATIONAL DESIGN REINFORCEMENT OR MANUAL OF STANDARD. PRACTICE FOR SPECIFICATION FOR WOOD CONSTRUCTIONS (NDS). DETAILING REINFORCED CONCRETE STRUCTURES. 10. APA. THE ENGINEERED WOOD ASSOCIATION. 4. A.C.I. 530-02 AND A.C.I. 530-1-02 FOR REINFORCED MASONRY. 11NATIONAL PEST CONTROL ASSOCIATION STANDARDS. 5• A.I.S.C. STEEL CONSTRUCTION A.S.D. FOR STRUCTURAL STEEL, 12A.C.1. 350.2R-04 CONCRETE STRUCTURES FOR CONTAINMENT NINTH EDITION. OF HAZARDOUS MATERIALS. 6• ANSI/AWS D1.4. 7. A.S.C.E. 7-02 FOR WIND ANALYSIS AND DESIGN. BASIC WIND VELOCITY 150 MPH. 24'-0" 144'-10" rk 24'-0" E I 24'-0" 24'-11" REINFORCING STEEL fy = 60,000 P.S.I. fs = 24,00o P.S.I. Es= 29,000,000 P.S.I. Em = 1,500,000 P.S.I. N = Es/Em = 19.33 ALL BLOCK 8" A.S.T.M. C-90 HOLLOW UNIT MASONRY DESIGN f'm = 1,500 P.S.I. GROUT SHALL COMPLY WITH A.S.T.M. C476, 28 DAYS MIN. COMP. STRENGTH = 4,000 P.S.I. CONTRACTOR TO CONSOLIDATE GROUT LIFTS WITH 3/4" VIBRATOR 42'-B" r------------ -- ---- ----------------------1 r-------- i F-1 r COMBINED FOOTING I ; F-1 ; F-1 I iV w/ #7 ® 9' o.c. TOP AND ; I I BOTTOM EA. WAY.am I I 0 I in _ P-1111 ; ; P-1 j P-1 1.. I xV I I I I = I I I r in I I I -00 SEE S1 07.1 a FOR THIS L- P-1i STRUCTURAL LAYOUT I j F-1 ----- --- THESE 12' I p— —I --- ---- AND SCTOANY CORRECT RRECTWORK V, 12'-0" 12'�0" gESND ALL PROPOSED REQUIRED �FIELD INSPECTORS IONS MAY BE THAT INORDER i000MPLYWITHALL APPLICABLE CODES, IrIII --_—* 7T _—_J _ r—i— ' IIII i M P-- -- - "in i i 11'r-2" 27'-8" 1 2� 2 23'-10" 23'-10" 10 7� P- i P ----i ----- --------- C--------i---- _ 1 -_ - 11 1 WF-36 WF-36 ° ---- _ _— n n L ____-1 -----, -----,------, 3 -0 3'-4" 5' - Cr1 ir) I I I I I I I I I I I ILF-S 'LF--5 ---J1 "1 21'-0" ---L� t13 00 II co O) bb 1 r__- iLI _F__51 10 - LiI F_-5 I -----J,I 111 ' 1 - �r3ll1i111 :o LF-SJ--- --N N I L1 II ------------ ----- _ �t _J II LiI l =o� LN O ao _ C1 n P, F-51 - F:5P-- -5A6vC�1 t D_7 to 11 I� rn LF-5 --�LF-5 ---J 'n I 1 to 1 4' 0"� 16'-6" '-4" '-8" �, r�nO ° C-1 _-I- ------- -1 L--------- O _.____ ___________ __J L---____1______ 1 (�1 _ __ _-----_-_J U- W N 0 t/C�WF-36 F-5A WF-36 - --- I --- - --- -WF 36------- ° -WF_ 36---- Ci 1 -----`J-------------E=fi--- --- (C=fl- z--- --(C1T 1 __ F-Sr------- 20 4" -, I I 11 I � II I I I I C-1 29'-0" 24'-4" i� a L0 - �i 6'-4" 35'-0„ ID " F- 4"x4"x1/4" STEEL I 4 lj COLUMN (SEE CONN. is E- 1 O_1 DTL. ON 1 05a) C71 I �Mr-, N Cri rr In I a al to r-------�,------� r-------L---T- i r -I -� 311 r- 7-------� 10 1y i P-111 I I I I W 1 I = 3 1 1 00 I.� N I I I I N I 11 O I 1 I 7 "?- I' � I 4„)11 I ' '-s5" �--I C-1 -36-3--- WF-36 --- ---( -I--- [WF---_-1------WF------ T -I------- C------_- 1, ' 8-0 _ I _ 5'-8" F-1 I I F-, -----4 _8 --- I -----�---------J L F—,1----- --- - L-------------- 144'-10" 188'-6" VDATION PLAN SCAI,E: I/8"=V-0" MM -o 43'-0" -4" 8'-01, 1'-0" DeNeB Design Group, LLC AA26001282 5835 Blue Lagoon Dr. Suite 200 Miami, Florida 33126 Tel. 786.275.8480 Fax 786.275.8474 www.dnbdesigngmp.com ALLIED NEW TECHNOLOGIES PLANT "MAIN BUILDING" FT. PIERCE, FLORIDA OWNER ALLIED UNIVERSAL CORP. 3901 NW 115th AVE DORAL ".88175 305.888.2623 DNB PROJECT NUMBER 07-120a OWNER'S PROJECT NUMBER ISSUED FOR: TYPE OF DOCS: CONSTRUCTION DOCUMENTS No. DATE REVISION BY 1 08-26-08 COMF. SET DF 9 02.26-09 COMF. SET DF DRAWN BY. • APPROVED BY: AZ F.D. DATE: SCALE: AS SHOWN CONSULTANTS: p\tea t+/ RAA1?I, J. Gonzalez, P.E. _ s SEAL/SIGNATURE This drawing Is the property of DNB Design Group and is not to be reproduced or copied In whale or part. It Is not to be used on am other project and is to be rehurned on request. SHEET TITLE SHEET NUMBERS 1 02 a