Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTe s� ��. �sTM�k ^.r 4 - 7.. ?'g Y .✓?£ v ,.wi.K'��'S' s5 3k �+ y vas � r e a z # �a o�Nt "I0P#RVALa� � u;� m. ��� a tea. _. •_ _ °� G .0 ulf�y Product valuation Report GULF COAST SUPPLY & MANUFACTURING, LLC 26 Ga. SV Crimp Florida Produ Florida Pe Subcai Compliance Prod (9 _0833Gulf Coast Sul 6�2c,�t�� R—Pff, 1442 Ne ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLI Pd_LE REVIEWED BY _ / E DATES Z Di AND PERMIT MUST BE KEPT ON JOB Florida SITE OR NO INSPECTION(S) WILL BE MADE FL# 11651.13 R3 - OCTOBER 5, 2017 Panel over 151.32" Plywood t Approval #11651.13 R3 uilding Code 2017 RECEIVED Rule 61 G20-3 MAR '2 S 1010 ethod: 1 -D Permitting Department St. Lucie County agory: Roofing gory: Metal Roofing lethod: 61 G20-3.005(1)(d) NON HVHZ THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT ct Manufacturer: COMPLNECESSARY WITH PPLIICABLE CODES. ply & Manufacturing, LLC. 2nd Place, Suite G30S+�'' /berry, FL 32669 �� `P�1 , , • • . lineer Evaluator: Kuhn, P.E. #75519 aluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 i F * • No. 75519 STATE OF <ORIDP'.`���.` 0 0NA L EN�`ioio si�o� CONCEALED FASTENERS OR A77ACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD CT I C ran DV Compliance Statement: Product Description: Panel Material/Standards: Panel Dimension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: FL# 11651.13 R3 • OCTOBER 5, 2017 The product as dIlescribed in this report has demonstrated compliance with the Florida Building i ode 2017, Sections 1504.3.2. 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Material: Minimlum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Op iional Yield Strength:180.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Sei tion 1507.4.3. Thickness: 0.018" Minimum Width: 1 24" Coverage Rib Height: I 3/8" Major Rib #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum) penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Minimum 75/32i thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Table "A" N1a?tr� rri Tat f 1i C�2st n PCessi r °2#A, , . Fastener Patiern 12"-12" 9.5"-2"-9.5" �, air'i P xis n aT+F 4 44 ,�, I� Design Pressure includes a Safety Factor = 2.0. Code Compliance: Gulf 'C' WoA. \ t SUPPLY-& MANUFACTURING -ibed herein has demonstrated compliance with the ode 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of he Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580i94 / 1897-98 Uplift Test Force E gineering & Testing, Inc. (FBC Organization # TST 5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan IKuhn, P.E. (FL# 75519) Q Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The ULI580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturingl under a quality assurance program audited by an approved quality assurance entitiy- Minimum Slope Range: Minimum Slopie shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. i Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classificatiI n is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL# 11651.13 R3 • OCTOBER 5, 2017 i GUIK5�Nt SUPPLY & MANUFACTURING Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project i� accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceed4 This evaluation report is not applicable in High Velocity Hurricane Zone. Kefer to current NOA or HVHZ evaluation report for use of this product in High 1 elocity Hurricane Zone. .o ■ 0 .D .0 ENGINEER LOAD TABLE: 26 Ga. 5VCrimp,� Roof Panel over 15/32" Plywood y M1I �tSa( �I �t�"'0 &Y. S1Nx �y *s.�(eEw�d7Sv''C 8 t £1q _ E ry(•~,jj �j�- ��733i 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.1/4" penetration) (MI N. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING i SPACING SPACING SPACING SPACING SPACING ,g# 4 i,�x�Il� -rr• �i ��yy^�. �..yRs,n'�§ k�*`ta r.L�y}��'Y'tc�<.Y�i�ii�%U,�,�Y Plywood 16" TYPE 1 16" T i PE 1 16" TYPE 1 16" TYPE 1 .....�' 1.a_ '".°td.....� s. 16" TYPE 1 16" TYPE 1 i 16" TYPE 1 ZONE 2 #9-15x1.5" 'tae 7� z �i hi @.� ClN� IM9i5x1i 1 T�t6) E 1�'� C Tyl')E� 16" YP 1 1i 2 76 TYPE t �y... yu>oaw „, �E _<._. gm' .N .. ..s�!.,cdt`...'3.1�'.az 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. ''/4" PENETRATION. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.2I5 PSFQ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. 15/3z" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. i W D DAAC ZONE 2 ZONE3-, ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... .... ..... r RIDGE ZONE 1 R Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be a less than' i either 4% of the minimum width of the building or 3 feet. TYPE FASTENER PATTERN ZONE 2 GABLE ROOF —. i j--RIDGE -'-------1---------------�a \ ZONE 1 N, ZONE 3 -SAVE FL# 11651.13 R3 • OCTOBER 5, 2017 (1) #9-15 x 1-1 /2" HWH w/Sealing Washer �12" 12" At Panel Lap — TYPE 2 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer �2119.5"--Z'9.5"2111 T i Underlayment is to be 30# ASTM D226 felt, tin tagged to code. o MAR 2 S IN Permitting Department St. Lucie County I P5 54bo 1q. MEASUREMENTS SQUARES LINE MEASUREMENTS Actual Squares: 40.26 Sqs. Eaves: Total Squares Rakes: (Inc. Waste at 11 %): 44.64 Sqs. Ridges: Hips: Valleys: Step: Wall: j Pitch Change: PITCH MEASUREMENTS CATEGORY MEASUREMENTS Pitch 5/12: 40.26 Sqs. Ice & Water Shield: Ridge Vent: Rake Edge: Eave Edge: Step Flashing: Apron Flashing: Gutters: Gutter Toppers: Down Spouts: RECEIVED MAR 2 8.2010 Perm ltting Department St. Lucle Count, 137 Ft. 194 Ft. 117 Ft. 0 Ft. 82 Ft. 0 Ft. 26 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft. 0 Ft.