Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSA� edel,a-1 & TESTING INC. i0 SW 13th Ave Pompano Beach, FL 33069 SCANNED RECEIVED MAR 2 8 2018 Phone 954-784-2941 800-848-1919 Fax 954-784-7875 fed-eng.com. . DATE: 3/12/18 I Job Order No.: R18174 CLIENT: Collins Roofing, Inc. ADDRESS: P.O. Box 12864, Ft. Pierce, FL 34979 PROJECT: Pensacola I ADDRESS: 8201 Pensacola'Road; Ft Pierce: FL :. 34953 ASCE 7=10 _DESIGN PRESSURE CAI:CULATIONS In Accordance with Chapter 30, Part I Proiect Information: Standing Seam ov I Sloped Wood Deck Mean Height = 18' Exposure: B. Ultimate Windspeed: V„jt= 170 mph Length= 55' Category: II Basic Windspeed: Vasd = 132.mph Width 50'. Slope: 3:12 KZ = ,0.70. Kd = 0.85 .Design Calculations:. Velocity Pressure: q : _.0.00256*[(0.70)(0.85)(1.0)(132)2] = 26.5 psf I Width of Pressure Coefficient: 0.1(50') . = 5.0' FILE COSY .0.4(18') = 7.2' } use: 4'0" Effective Wind Area: <10ft? . For parapet height three feet (3') or larger, zone three (3) can be treated as zone two (2) (ASCE740). External Pressure Coefficient: ! Internal Pressure Coefficient . 1).: GCP1 = '-0.9 1) GCPi = 0.18 2) GCP2 -1.7 3). GCP3 = -2.6 ; M.®DARE Construction Material American Concrete Miami Dade, Florida Department Engineering Council Institute County of Transportation V ENGINEERING & TESTING. Page 2 3/12/18 Sloped Wood Deck Section 8207 Pensacola Road Ft Pierce, FL Design Pressures: 1) Field P1 = 26.5*.(-0.9 — 0.18) _ -28.7 psf 2) Perimeter P2 = 26.5*(-1.7 — 0.18) = -49.9 psf 3) Corners P3 26.5*(-2.6 — 0.18) _-73.8.psf Attachment Requirements: Based on RAS-133 and F.L. #17022-R7 (17022.1); Table A ; , the following are our recommended fastening requirements for the 26 gauge 5V Crimp Metal Roof Panels: Field: Maximum of .12 o./c. screw spacing (Table A - #9 Screws "Method -1) Perimeter: Maximum of 12" o.%c; screw spacing, (Table A - #9 Screws "Method 1) Corners:.: Maximum of 12".d:/c. screw spaciug (Table A - #9 Screws "Method 1). j r` Proiect Inf6rmafion: Flat Wood Deck 'Height = 10' Exposure: B Ultimate Windspeed: V„ If= 170 mph Length = 55' Category; H. Basic Windspeed: Vasa = 02 mph Width = 18' Slope'. < 7° KZ = .0.70 Kd.=.0.85,- Parapet Wall:- < 3' ; _Design Calculations:.. ; Velocity Pressure-' q' 0.00256*[(0.70)(0'.85)(1.0)(132)2] 26.5 psf Width of Pressure Coefficient: 0;1(18') = 1.8' j 0.4021) .4.8' } use: 4'0" .Effective Wind Tributary Area: <1 Oft' For parapet height 3 feet.or larger, zone.three (3) can be treated as -zone. two (2) (ASCE 7-10). . r ` Page 2 3/12/18 Flat Wood Deck Section 8207 Pensacola Road Ft Pierce; FL ' External Pressure Coefficient: 1) GCPl = 4.0 2) GCP2 . = -.1:.8 3) GCP3 72.8 Design -Pressures: Zone 1. Field:.' P1 26.5(21.0'- 0.1.8) 731.3 psf, Zone:2. Perimeter: • P2' 26,5*('-1,:8;= 0.18).=' -! 215 psf. . Zone 3 Corners:. P3 = 26.5*(2.8._ 0.18).— -79.1 psf Fiat Roof Section Attachment Requirements: . 4 Based on RAS-117 and F.L..#1'654-R22; Table .1G. System Type F; System No. W-140; With a design pressure of -90 psf; Appendix 1; page 21 of 58-,- the following-systern is approved with all layers fully bonded i Notes: Cornersand perimeter area dimension shall not be less•than 'a = 4'0" All work.shall.be in compliance with.the local building code product control notice .. of acceptance and manufacturers specifications and .the Florida Building Code 2017: Wind load,calculations based on ASCE 7-10' and information provided by client. All woik' shall be inspected by our field engineer :or city inspector to verify compliance with specifications.:: i I' Sincerely;. r 4..: eith LeBlanc; P.)✓: FedzraL k,nginering & eating; Inc. Florida Reg. Nq: 59394` Certificate of Authorization #5471 f 1i,4i— mi-Dade' County ,,C�6rtification #16 '0203.07