Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEMUlm 11Is 11611, ism SCANNED Business & Professional RegulationBy qt P I BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats a b a I ' ' Product Approval USER: Public User 2 �s�. s9�sjlxm . Product Approval Menu > Product or ADplication Search > implication List > Application Detail r f DBPRHOW ABOUTDSPR Q11PRUIVISIONS rCONTACT0817ft FL # FLX654-R22 Application Type Revision Code Version 2017 RECEIVED Application Status Ap ved MAR 2 8 2018 Comments Archived D ST. Lucie County, Perrrllid�� Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1378 Ext242 alender@polyglass.com Authorized Signature Ariel Lender alender@polyglass.com Technical Representative Maury Alpert Address/Phone/Email lilt W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass.com Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) J Validation Checklist - Hardcopy Received FL1654 R22_CrQI_2017_03 COI Nieminen.pd Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 r UL 1897 j 1 � Equivalence of Product Standards • Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/14/2017 Date Validated 09/15/2017 Date Pending FBC Approval 09/22/2017 Date Approved 12/12/2017 Summary of Products 2012 FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVH2: No FL1654_R22_II 2017 09 FINAL Al ER POLYGLASS MODBIT_FL1654- 1122.pdf Approved for use outside HVH2: Yes Impact Resistant: N/A ' Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application Created by Independent Third Party: Yes Evaluation Reports relates to one particular assembly over concrete FL1654 R22_AE_2017 09 FINAL ER POLYGLASS_M DBIT LF 1654- R22.pdf deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits Created by Independent Third Party: Yes of Use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe ��TRRINITYJERD ( APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE ( Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top insulation, Bonded Roof Cover 22-24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 --- -5E--- -- -- CWF_ _ New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum ------- Reroof (Tear -Off)- - A-1 Bonded Insulation, Bonded Roof Cover 50-52 68 Gypsum Reroof (Tear -Off) or Recover -A-2- - Mech.-Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover- _ 53 -J 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-Inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published installation Instructions. 3. Unless otherwise noted, Insulation may be any one layer or combination of polylsocyanu rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. . Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report P9290.02.08-1120 for FL1654-R22 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58 -,,rTRINITYIERD 15. Unless otherwise noted, refer to the followinR references for bonded base, olv or caD sheet aaDlications. TABLE 1: POLYGLASS ROOF COVERS Reference Layer Material Application BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type 11 (Base and Ply sheets, Asphalt- Hot Asphalt at 20-40 Ply One or more lies Polyglass PI IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Applied) Note: Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes. Ibs/square Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex 56 Type 11, Polyglass HT Base 650 SBS-CA3 PG350 at 1.5 2.0 gal/square Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One I Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Tye II SBS-CA2 Polyplus 35 at 1.5-2.0 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex SBS-AA 56 Type II, Polyglass HT Base 650 Hot Asphalt at 20-40 Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, (SBS, Asphalt -Applied) Ibs/square Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) - Note: Asphalt -applied sheets or insulation shall not be applied to poly f Im surfaced membranes. Base Ply or Ply 650 or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex 56 Type 11, Polyglass HT Base SBS-TA (SBS, Torch -Applied) Torch -Applied Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Cap Ply Elastoflex SA P, Elastoflex 5A P FR, Pal reflect SBS-SA (SBS, Self -Adhering) Self -Adhering Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Elastobase of sand or of 1 (P Y/ J ( r/Pa yl. -APP=CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 -- - ----- -- gal/square APP-TA Base Ply or Ply -One -or more -plies Polyglass APP Base, Polyflex, Polybond (APP, Torch -Applied) Ca nd Ply Polyflex, Polyflex G, Polyflex G FR, Pal bo,Polvbond G,-Polyfresko_G, Polyfresko G FR Torch -Applied 16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ P6200 Non Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; D P6650 Fibered Aluminum Roof Coating; D PG700 High Quality Elastomerlc Roof Coating or KM Acryl 25; ➢ PG700QS (Quick Set) High Quality Elastomerlc Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomerlc Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick Set) Premium Grade Elastomerlc Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only); D Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, I.I.C. d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for F1.3654-1122 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-100 Appendix 1, Page 3 of 58 ��TRINITYJERo TABLE 1F-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) (Psf) Type Fasten Attach Base Ply Cap SELF -ADHERING BASE PLY: - W-136 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-Inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- _52.5' Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA W-137 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch c.c, in two Polyflex SA Base APP-TA -52.51 Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-Inch o.c. in 4-inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SB5- -60.0" Inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA W-139 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-Inch lap and 12-Inch o.c. in two Polyflex SA Base APP-TA 60.0` Inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE 1G: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap Ply No W-141 Min. 15/32- (Optional) PG300 None Polyflex SA Base (Optional) APP-TA APP TA 90.0 Inch plywood — —W-142 --Min..15/32= _ _ PG100-__________ None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS 97.5 inch plywood - ----- -- _ _ TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, -rolled -into -- _Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, 5BS W-143 Inch plywood (Optional) PG100 place to create continuous band. Elastoflex SA V FR Base TA, APP=TA -- - - TA, AP-P_-TA_ 97.5 W-144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- -105.0 Inch plywood TA, APP-TA W-145 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -135.0 inch plywood place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA W-146 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APP TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity IERD ,Certificate of Authorization #9503 Prepared by: Robert Nleminen, PE-59166 67 EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Evaluation Report P9290.02.08-1120 for F1.3654-1122 Revision 20: 09/12/2017 Appendix 1, Page 21 of 58