HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSdOOr
_.SCANNED
.; ProductApproval
g USER: Public User
��
St Lucie C®U10
Product Aooroval Menu > R oduct or Aoolication
Search > Aooliation List > Application Detail
•r.?-* <<- ir:,
FL #r
Application Type
FL2569-1113
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
PH !1§atT F Ps[?l ati<}"5 as'gpCi
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
REVIEWS BY
DATE` �c�
'PLANS AND PERMIT MUST BE KEPT ON JOB
SITE OR NO INSPECTIONS) WILL BE MADE
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
1 (819) 478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888) 811-3145
THESE PLANS AND ALL PROPOSED
jfcote@soprema.ca
WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
Category
Roofing
NECESSARY INORDER TO
COMPLY WITH ALL ODES.
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License
Quality Assurance Entity
UL LLC66
UL LLC
FILE COPY
Quality Assurance Contract Expiration Date
07/18/2020
Validated By
John W. Knezevich, PE
V Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
FL2569 R13 COI 2017 01 COI Nieminen.odf
Standard
Year
ASTM D1970
2015
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
TAS 110
2000
UL1897
2012
https:!/floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBI08ErxlUd3xYlp02ib3vkhsvCVHcvjHpOtA%3d%3d 1/2
1/4/2018
r1U11Ud ouuuuiy L,uuo
Equivalence of Product Standards
Certified By
i
Sections from the Code
I
i
Product Approval Method
i
Method 1 Option D
i
Date Submitted
10/09/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/15/2017
Date Approved
12/12/2017
Summary of Products
FL # Model, Number or Name I Description
2569.1 Soprema Roof fSelf adhering roof underlayments
Underlayments l i
jLimits of Use
j Approved for use in HVHZ: No
Installation Instructions I
IFL2569 R13 II 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
I Approved for use outside HVHZ: Yes
R13.odf
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166 '
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
I other: 1.) Refer to ER Section 5 for Limits
of Use. 2.) The design pressure noted herein
Evaluation Reports
I I FL2569 R13 AE 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- .
pertains to underlayment systems used
R13.odf
I beneath adhesive -set tile systems. Refer to
Created by Independent Third Party: Yes
I ER Section 5.6.4 for details.
i
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cooyriohlt 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If yogi do not want your e-mail address released in response to a public -records request, do not send electronic
on
to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
ON W - ® -
Credit Card
Safe
https://loridabuilding.org/pr/pr_app_dtl_aspx?param=wGEVXQwtDgsKO EnckB1 08Erx1 Ud3xYlpO2ib3vkhsvCVHcvjHpOtA%3d%3d 2/2
i �-•
TRINITY ERA
EVALUATION REPORT
Soprema, Inc.
1640 rue Haggerty
Drummondville, Quebec J2C 5P8 Canada
(819)478-2400
SCOPE:
This Evaluation Report is issued under Rule 61G20-
construction materials in the State of Florida. The d
P.E. for use of the product under the Florida Buil
products described herein have been evaluated fc
sections noted herein.
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report S18010.06.09-R11
FL2569-R13
Date of Issuance: 06/15/2009
Revision 11: 10/06/2017
and the applicable rules and regulations governing the use of
:umentation submitted has been reviewed by Robert Nieminen,
ing Code and Florida Building Code, Residential Volume. The
compliance with the a Edition (2017) Florida Building Code
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is vali
Quality Assurance documentation changes, or provi!
this Evaluation Report by the named client consti
changes or the referenced Quality Assurance docurr
Evaluation Report relative to updated Code requiren
ADVERTISEMENT: The Evaluation Report number pre(
advertising literature. If any portion of the Evaluatic
INSPECTION: Upon request, a copy of this entire EvalL
its distributors and shall be available for inspection
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
I until such time as the named product(s) changes, the referenced
ons of the Code that relate to the product change. Acceptance of
utes agreement to notify Robert Nieminen, P.E. if the product
2ntation changes. Trinity I ERD requires a complete review of this
ents with each Code Cycle. -
2ded by the words "TrinityI ERD Evaluated" may be displayed in
r Report is displayed, then it shall be done in its entirety.
Ition Report shall be provided to the user by the manufacturer or
the job site at the request of the Building Official.
• J �•. R -- , . - ? •••
•, ,(�,�.•, „� : - The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10106/2017. This does not serve as an
����•..i+++++ ` electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by anylcompany manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, ai financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous vei sions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
ERD
TRINITY
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments,' as produced by Soprema, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
i
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
gn!Lty
Examination
Reference
Date
ERD (TST6049)
ASTM D1970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 /TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-Ri
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
57120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970/TAS 110
S13190.02.09-R1
04/01/2010
ERD (TST6049)
ASTM D1970/TAS 110
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (T5T6049)
Accelerated Weathering
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-R1 06/07/2017
M-D (CER1592)
HVHZ Compliance
15-0508.04
09/24/2015
[CC -ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
PRI (TST5878)
Physical Properties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets
ASTM D1970 and FRSA/TRI April 2012
(04-12).
4.2 Lastobond Shield
is a self -adhering, woven polyethylene
surfaced, SBS
modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof
underlayment; available
in 3.3 ft x 65 ft rolls; meets ASTM
D1970.
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene
surfaced, high temperature, SBS modified
bitumen roof underlayment;
meets ASTM D1970.
Exterior Research and Design, I.I.C. Evaluation Report 518010.06.09-Rll
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R13
i Soprema, Inc. Revision 11:10/06/2017
1 Page 7 of 8
i
TRINITY ERD
4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths 36 and 45 inch; meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self-adherii g, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.8 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.10 Lastobond Smooth Seal HT is a self -;adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen
roof underlayment; meets ASTM 01970.
4.11 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.12 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlaymentl with a 36-inch sheet width; meets ASTM D1970.
4.13 RESISTO LB1244 is a self -adhering) glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with a 44-inch sheetwidth; meets ASTM D1970.
4.14 Colphene FIR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
5. LIMITATIONS:
5.1 This is a building code evaluation. Nieither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report- refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on t is evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
i
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Yes
Lastobond TU HT
Y
Yes
Yes
Yes
Yes
See 5.5.1
Lastobond Shield / Pro HT-N / RESISTO SA
Yes
TVo
Yes
Yes
SMOOTH PLY 40fi,
rti3'Nof
;,�No�_
Lastobond Shield HT / Pro HT-5
Yes;
" #
Nor,
2Fq
Yes
Yes
Yes
Lastobond Eaves Protection Sheet/_
;.
%4�sNo
Our
'
Yes
Yes
Lastobond 195
Yes
rya.-Nox
Y
? No
Jy#
Lastobond ECO / RESISTO LB1236, Grip -
'fro
Rite Eave &Valley Protector / RESISTO
Yes
;Noy
o� £,;
Yes
Yes
LB1244
Exterior Research Research and Design, I.I.C. Evaluation Report S18010.06.09-R31
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL2S69-R13
Soprema, Inc. Revision 11:10/o6/2017
Page 3 of 8
r' TRINITY ERD
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Nail -On
Tile
Foam -On
Tile
Metal
Wood Shakes &
Shingles
Slate
Lastobond Smooth Seal HT
Yes
Yes
Yes
Yes
Colphene FR GR
Yes
Yes
Yes...
See 5.5.1
-No K:
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of folI llowing Approved the adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS,
Adhesive
Florida Product Approval
Underlayments
Dow TileBond-
FL22525
Lastobond TU HT
ICP Adhesives Polyseta AH-160
FL6332
Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or El,astocol 600c if the final roof cover is not slated for installation within
24 hours.
Y Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to
installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40,, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley ProItector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR
GR applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807.
I
I Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-Rll
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL2S69-R13
Soprema, Inc. Revision 11: 10/06/2017
Page 4 of 8
5.6.3
F
TRINITY ERD
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Prot ector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; Soprra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12).
5.6.4 Wind Resistance for Underlayment ISystems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
i
already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind
pressures.
41 Maximum Design Pressure = -45.0 p f:
Deck: Min. 15/32-inch'plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) Elastoc�ol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#2 Maximum Design Pressure = -67.5 pst:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Elastocol600c
Underlayment:
Lastobond TU HT or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or
weighted roller to ensure there are no voids, and ensure there are no voids/bridging at
side and end -laps
#4 Maximum Design Pressure = -60.0 psf:
Deck:
Min. 19/32-inch iplywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.51.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment:
Lastobond TU HTor Colphene FR GR, self -adhered
5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a
Maximum Design Pressure of -45 psf.
Exterior Research and Design, I.I.C. Evaluation Report 518010.06.09-Ril
certificate ofAuthorization A9503 6"' EDITION (21 17) FBC NON-HVHZ EVALUATION FL2569-R13
Soprema, Inc. Revision 11:10/06/2017
Page 5 of 8
�.' ERD
TRINITY
I
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design) pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastabond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR G,R shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 pier FRSA/TRI April 2012 (04-12)):
i
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitatiions can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREd-DECKTILE INSTALLATIONS
Underlayment I
i
Tile' Profile
Staging Method
Maximum
Slope
Lastobond TU HT
Flat
Max. 10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Lugged
i
I
i
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
1
Max. 10-tile stack 5:12
Colphene FR GR
Flat
Lugged
Max. 10-tile stack 6:12
Exterior Research and Design, I.I.C. Evaluation Report S1B010.06.o9-R11
Certificate of Authorization#9503 6m EDITION,(2017) FBC NON-HVHZ EVALUATION F1.2569-1113
Soprema, Inc. Revision 11:10/06/2017
Page 6 of 8
•i TRINITY ERD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels) and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER l(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield
HT, Lastoboncl Pro �HT-$, Lastobond Eaves Protection' Sheet, Lastoboiicf 195,- l.astobond Eco, Lastoborid
Smooth Seal HT, RE51STO LBI236. Grip -Rite Eave & Valley'Protector, RESTS_ T_O Li31244 or Colphene FR Gk-
6.3.1 Shall be installed in compliance wltn the requirements nor F►)im Lj.Lvru uuuciayuicuill
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI!April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and Soprema published requirements for the staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R11
Certificate of Authorization k9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1113
Soprema, Inc. Revision 11:10/06/2017
Page 7 of 8
TRINITY' ERD
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements.
Tho fnllnwina nlant, have nualified Droducts under their respective physical properties specifications.
Plant
Specifics#ion
Frocluct s
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-N, Lastobond Pro HT-S, Lastobond 195, Lastobond
Drummondville,
ASTM D1970
Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth Seal HT,
QC (Canada)
RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector,
RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 04112
Lastobond TU HT; Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Gulfport, MS
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us-ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-Rli
Certificate o(Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-RI3
Soprema, Inc. Revision 11:1o/06/2017