Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTSCANNED AtLudecountv St Lucie Coin ty Building & Zoning w 2300 Virginia Avenue Ft Pierce, FL 34982 Mobile Homellnspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both s �l�es of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: Address: (Print or type) rLoAc-5 DES Of Year / Manufacturer I /U ( Li — Width—!—'-J__—. __Length__ —I_ Lt._ __ Single C = In Compliance N = Not in Compliance Fire G 1. Smoke Detector: Installed Mi Date: P ID 7(-rl' PAN15146� 8cp,4F FL oulmy Ltot-4s . 7w2&i9a cbf 9A 3a7G 03 Serial # HUD Plate G o!f Double b Wind Zone�� / Electrical C 2. Electrical System Checked: Exposed Wiring Other —C 3. Distribution Panel: Missing 4ose Main Missing Breaker Missing Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire GFCI receptacles not where required G 5. Electrical Ground: Chassis Main Panel Gas Pipe I I ` Revisal 3/9/05 I age o f 1. Exit Doors Operable: Front G 2. Exit Door Locks: Missing Inopei Ci 3. Egress windows: Missing Inop �i 4. Windows: Broken Glass Inoper G 5. Screens: Missing Damaged C 6. Floor System: Joist De0 C_ 7. Interior Paneling: Missing Loose 8. Rodent Proofing: Bottom Board Pipe c G 9. Leaks Apparent: Ceiling Doors F L 10. Vertical tie -down straps: Missing Shc Ce 11. Structural modifications since manufacture C. 12. Walls: Structurally Unsound Loose _C 1. Trap: Missing Not connected G 2. Plumbing fixtures: Missing Not in: C 3. Relief Valve: Missing InoperE _ 4. Drain Waste and Venting Piping: Missin Clean outs Use of fittings _ Heati G 1. Heating Appliances: Miss G 2. Deleted Heating/AC system: Not i 3. Thermostat: Miss Other Area Damaged imaged nings Other )r Roof Damaged YES_ NO__V/ _ Weather tight mbing Other j Not Vented Other Not supported Notcapped and Air Conditioning Not Connected Other. :d Other - Inoperable Ci 4. Air registers: Missing i Inoperable G 5. Ducts: Not sealed Missing Collapsed ° Page 2 of 3 ®� C_ 6. Gas furnace Water heater vent: Missing G 7. Return Air: To Furnace To A/C Co 8. Range: Vent Hood G 9. Gas Valve: Accessible- C. 10. Gas lines: Summary Not capped Not Not bonded 1. Is subject structure found to be fifty (50%) or more 2. Will a remodeling permit be required? YES The provisions of the repair and remodeling code shall than those standards required to be met in the manufac limited to, standards for -structural adequacy, plumbing, ti _ Loose 1 rooms improperly ed Kinked. imaged or deteriorated? YES NO V000'0 NO e isure safe and livable housing and shall not be more stringent ire of mobile homes. Such provisions shall include, but not be gating, electrical systems, and fire and life safety._FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APP i ICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED LOCATED WITHIN ST. LUCIE COUNTY U BE MOVED TO ST. LUCIE COUNTY OR RE - THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL Date inspected: /.7 e% ! �! Inspected By: 5—MUE- Signature required Q+ Phone Number: f�(!�,) Page 3 of 3 MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX SEAL. JT31bl /- a $ -M Engineers Seal STEVEN G. WOOD, D.E. y L LICENSE 34398 960 S��irJLTAN DflB�.,-r� ]pN1'1Lb11 ►'J1 LUCIE, ]L L