Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION3 f St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce; FL 34982 Mobile Home Inspection Report SCANNED) By S$ Lucie Coo0tv All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: Address: Year / Manufacturer Width _ _ ____ _Length_ __ a __ Single C = In Compliance N = Not in Compliance uate: � 5 P Nl 5 H LAKE5 P��c-.. rRWAVS M4P � .�F�tt s Se�f#446TD58X5rS36BUD Plate # aA Ss& t 2 (p Double_ Wind Zone_ Fire Safety / Electrical L 1. Smoke Detector: Installed Missing C 2. Electrical System Checked: Exposed Wiring Other G 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening' Other Ci 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire GFCI receptacles not where required Ci 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 3/9/05 Page 1 of 3 1 Construction Ci 1. Exit Doors Operable: Front Back Other _— 2. Exit Door Locks: Missing Inoperable— C 3. Egress windows: Missing Inoperable __C__ 4. Windows: Broken Glass Inoperable C 5. Screens: Missing Damaged , 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing Loose ! Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other 9. Leaks Apparent: Ceiling Doors Floor Roof C 10. Vertical tie -down straps: Missing Short Damaged --C,-_ 11. Structural modifications since manufactured: YES_ NO_�Z C 12. Walls: Structurally Unsound Loose Weather tight _ Plumbing G 1. Trap: Missing Not. connected Other �. 2. Plumbing fixtures: Missing Not installed Not Vented G 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and' Air Conditioning 1. Heating Appliances: Missing Not Connected Other G 2. Deleted Heating/AC system: Not installed Other. C 3. Thermostat: Missing Inoperable C4. Air registers: Missing Inoperable Ci 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 t 6. Gas furnace Water heater vent: Missing Loose 7. Return Air: To Furnace To A/C From rooms Q 8. Range: Vent Hood _ 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not', supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO�� 2. Willa remodeling permit be required? YES NO—J/— The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited -to, -standards for --structural adequacy, plumbing; heating,.. electrical systems, and .fire -and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER�AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND',THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: I lag 410 Inspected By: Signature required Phone Number: ((//y'►1bM-73W THEIR SEAL. License # ✓ 6 3 Jy 1 o?$ /f Eng/ rs S Page 3 of 3 STE'V N G. WOOD, P.E. y L LICENSE 34398 7�o SULTAN go(�rpT�lgD�R g