HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSSCANNED BY Lucie. rn1j* : HOM E PRIDE Manufactured Housing Installation Instructions Lock Down Anchoring System } Wind Zones 2 & 3 IF'L i FD -CORI FAI He Copj. I -Beam Connection �II �W Lateral/Longitudinal Strut �5-0 Anchor & Stabilizer NOTE: If one or more of the following conditions exist contact a Ragistered Professional Engineer. • Location is within 1,500' of the. coastline. • Pier Height exceeds 48". • Roof eaves exceeds 16". • Sidewall height exceeds 96". • Length of home exceeds 76'. REQUIREMENTS FOR USE 1. The use of the Lock Down Anchoring System requires side all vertical ties at no greater than 5'4" on center. 2. Centerline anchors to be sized according to the soil torquel conditions. 3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor. 4. Sidewall vertical ties can use 4' anchors in soil type 4B. Facing the home Facing the home LEFT CORNERI RIGHT CORNER 5. Homes requiring 4 Lock Down Anchor— assemblies require the longitudinal and lateral strut on each anchor. All struts must be installed towards the center of the home. Facing the hot LEFT CORNER 6. Homes requiring 61ock Down Anchor assemblies, only require longitudinal struts on the 4 corner positions. The two center positions only require a lateral strut. All struts must be installed towards the center of the home. 7. The placement of the corner systems should be at a each corner. 1. H0M.,E DE Facing the home Facing the home CENTER RIGHT CORNER ill vertical tie that falls no more than 11' and no less than 5' from the end of the house on too NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED: Wind Zones 2 & 3 with roof pitch 6/12 or less. • Single or Double section homes 30' to 52 in length -(excluding hitch) • Single or Double section homes greater than 52' to 76' in lei gth (excluding hitch) NOTE: Roof pitches greater than 6/12 will require additional system! NOTE: Homes less than 30' — Lock Down System should not be used. NOTE: Home manufacturers may provide a placement chart for spec chart below. ANCHOR ASSEMBLY PLACEMENT Using 4 Anchor Assemblies W DO 101 IM11 11®i 9 Lock Down_ Anchor Assembly Components List 1. Ground Anchor with Strut Attachment Cap 2. Stabilizer 3. Lateral Strut 4. Longitudinal Strut S. Beam Clamp Assembly Lock Down_Anchor-Assembiv Installation instructions contact Home Pride, Inc. for assistance. models in their installation manual. The manufacturer's placement chart supersedes the Using 6 Anchor Assemblies �i�i�+ � iRa ■fir 14 The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor and align with a sidewall vertical strap. Install this anchor at a slight angle, not to exceed 15 degrees. This assembly includes a stabilizer plate that is installed with the anchor and attached with a U-bolt and two nuts. The stabilizer plate should be driven into the ground when the anchor is about 2/3 installed. Attach the stabilizer to the anchor shaft using the U-bolt and nuts then complete the install of the anchor until the strut attachment cap is flush to the.ground or slightly recessed into the ground, no more than Y". 'The Strut Attachment Cap should be Installed within A" or flush to the top of the stabilizer plate. (See illustration to the right.) I NOTE: State of Florida allows.a 2',pilot holes to,be drilled to assist anchor installation in extremely hard soil conditions: If this process is used during installation of the Ground Anchor with Strut Attachment Cap the soil must be placed back In the pilot hole and compacted at 6" intervals. This process should take place when the anchor is 8"-10" from fully installed — allowing room for the soil to be placed back in the pilot hole and properly packed. HOME PRIDE 2. Once the ground.anchor assembly Is fully installed, attach longitudinal and lateral struts accordingtothe diagram under anchor assembly placement (page 1.). The lateral -arm fasteners are to be Installed tightly (nuts and bolts). The Beam Clamp assembly has two holes for the bolt and nut placement. Depending'on the width of the beam, the corresponding hole should be used that pushes the frontof the metal plate as close as possible to the upright of the beam. See the illustration on page 2, #5. Lateral struts should be Installed in line with the center anchor head Lateral strut angles must fall within 10 degree minimum - 60 degree LonpltudhWl Shut r Lateral Strui Attached Point SSdowa113nap conneetion attached at the top of the I-beam. Longitudinal strut angles must fall within 10 degree minimum -50 degree maximum. Longitudinal Stmt Attache! Point Facing the home RIGHT CQTMR 0 ' Loiiralstrut Attached Point Sldewall Strap Connection After the Lock Down Anchor Assemblies have been fully installed and ell permiter anchors and straps fully installed.and tightened — each strut has 4 self tapping screws that must be installed as the final step. Predrilled holes are provided on the outer strut indicating placement. if the predrilled holes can notbe accessed, iwN i! ♦Ln ne..n.... nn ..nn.n M ♦k n.nA ill i.nin. m nne.i Men _ ...o Line.. +k—,, t•inn inf-n r6n inner ef..4 The Lock Down Anchoring System should only be used for homes in the other state. Contact Home Pride Inc. 276-466-0502 or at contactus0h Panehors.com Legacy Engineering listing # 113 Notes: Tate of Florida. This anchoring system is not designed, tested or approved for use in any for any questions concering this product. I I PRODUCT WARRANTY Home Pride warrants its Lock Down Anchor System (HP LDS) against defects designedand approved for use in the State of Florida. This product.is not be reused,or reinstalled at any other location. If used in violation In workmanship and material at the she of its initial installation. The HP LDS is specifically not approved for use and should not be used outside the State of Florida. This product must of this Warranty or not installed in accordance with installation instructions, all written and Implied warranties are void and,disciaimed. HP LDS products which are found to have defects will be repiaced,or repaired at Home Pri e s option. T is Express Warranty Is limited to:replacement of product only and does not cover any laborior installations costs. When the product is replaced, all Warranty rights are extinguished. This Warranty is only to the benefit of the original purchaser and is nottransferable. There,are no other warranties (express orimplied) whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home Pride disclaims any and all otherimplied warranties, Including (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose to the extent allowed by law and any Implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty. These limitations shall be enforceable to the extent permitted by law. I HP LDS products which are examined and are found notto be defective will be returned to user and all costa associated with examination of the anchor product will be incurred by the user. The user is responsible for all maintenance of the HP LDS product including regular monitoring of stability and integrity of HP LDS products. For a warranty claim, contact your distributor or Home Pride Inc. at 3, HO�P—RI DE Industrial Park Road, Bristol, Virginia, 24202.