HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSSCANNED
BY
Lucie. rn1j* :
HOM E
PRIDE
Manufactured Housing Installation Instructions
Lock Down Anchoring System
} Wind Zones 2 & 3
IF'L
i FD -CORI
FAI
He Copj.
I -Beam Connection
�II
�W
Lateral/Longitudinal
Strut
�5-0
Anchor &
Stabilizer
NOTE: If one or more of the following conditions exist contact a Ragistered Professional Engineer.
• Location is within 1,500' of the. coastline.
• Pier Height exceeds 48".
• Roof eaves exceeds 16".
• Sidewall height exceeds 96".
• Length of home exceeds 76'.
REQUIREMENTS FOR USE
1. The use of the Lock Down Anchoring System requires side all vertical ties at no greater than 5'4" on center.
2. Centerline anchors to be sized according to the soil torquel conditions.
3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor.
4. Sidewall vertical ties can use 4' anchors in soil type 4B.
Facing the home Facing the home
LEFT CORNERI RIGHT CORNER
5. Homes requiring 4 Lock Down Anchor—
assemblies require the longitudinal and lateral strut on each anchor. All
struts must be installed towards the
center of the home.
Facing the hot
LEFT CORNER
6. Homes requiring 61ock Down Anchor
assemblies, only require longitudinal
struts on the 4 corner positions. The
two center positions only require a
lateral strut. All struts must be installed
towards the center of the home.
7. The placement of the corner systems should be at a
each corner.
1. H0M.,E DE
Facing the home Facing the home
CENTER RIGHT CORNER
ill vertical tie that falls no more than 11' and no less than 5' from the end of the house on
too
NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED:
Wind Zones 2 & 3 with roof pitch 6/12 or less.
• Single or Double section homes 30' to 52 in length -(excluding hitch)
• Single or Double section homes greater than 52' to 76' in lei gth (excluding hitch)
NOTE: Roof pitches greater than 6/12 will require additional system!
NOTE: Homes less than 30' — Lock Down System should not be used.
NOTE: Home manufacturers may provide a placement chart for spec
chart below.
ANCHOR ASSEMBLY PLACEMENT
Using 4 Anchor Assemblies
W DO 101 IM11 11®i
9
Lock Down_ Anchor Assembly Components List
1. Ground Anchor with Strut Attachment Cap
2. Stabilizer
3. Lateral Strut
4. Longitudinal Strut
S. Beam Clamp Assembly
Lock Down_Anchor-Assembiv Installation instructions
contact Home Pride, Inc. for assistance.
models in their installation manual. The manufacturer's placement chart supersedes the
Using 6 Anchor Assemblies
�i�i�+ � iRa ■fir
14
The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor
and align with a sidewall vertical strap. Install this anchor at a slight angle, not to exceed
15 degrees. This assembly includes a stabilizer plate that is installed with the anchor and
attached with a U-bolt and two nuts. The stabilizer plate should be driven into the ground
when the anchor is about 2/3 installed. Attach the stabilizer to the anchor shaft using the
U-bolt and nuts then complete the install of the anchor until the strut attachment cap is
flush to the.ground or slightly recessed into the ground, no more than Y". 'The Strut
Attachment Cap should be Installed within A" or flush to the top of the stabilizer plate.
(See illustration to the right.)
I
NOTE: State of Florida allows.a 2',pilot holes to,be drilled to assist anchor installation in extremely hard soil conditions: If this process is used during installation
of the Ground Anchor with Strut Attachment Cap the soil must be placed back In the pilot hole and compacted at 6" intervals. This process should take place
when the anchor is 8"-10" from fully installed — allowing room for the soil to be placed back in the pilot hole and properly packed.
HOME PRIDE 2.
Once the ground.anchor assembly Is fully installed, attach longitudinal and lateral struts accordingtothe diagram under anchor assembly placement (page 1.). The
lateral -arm fasteners are to be Installed tightly (nuts and bolts). The Beam Clamp assembly has two holes for the bolt and nut placement. Depending'on the width of
the beam, the corresponding hole should be used that pushes the frontof the metal plate as close as possible to the upright of the beam. See the illustration on page
2, #5.
Lateral struts should be Installed in line with the center anchor head
Lateral strut angles must fall within 10 degree minimum - 60 degree
LonpltudhWl Shut
r Lateral Strui
Attached Point
SSdowa113nap
conneetion
attached at the top of the I-beam.
Longitudinal strut angles must fall within 10 degree minimum -50 degree maximum.
Longitudinal Stmt
Attache! Point
Facing the home RIGHT CQTMR
0
' Loiiralstrut
Attached Point
Sldewall Strap
Connection
After the Lock Down Anchor Assemblies have been fully installed and ell permiter anchors and straps fully installed.and tightened — each strut has 4 self tapping
screws that must be installed as the final step. Predrilled holes are provided on the outer strut indicating placement. if the predrilled holes can notbe accessed,
iwN i! ♦Ln ne..n.... nn ..nn.n M ♦k n.nA ill i.nin. m nne.i Men _ ...o Line.. +k—,, t•inn inf-n r6n inner ef..4
The Lock Down Anchoring System should only be used for homes in the
other state.
Contact Home Pride Inc. 276-466-0502 or at contactus0h Panehors.com
Legacy Engineering listing # 113
Notes:
Tate of Florida. This anchoring system is not designed, tested or approved for use in any
for any questions concering this product.
I
I
PRODUCT WARRANTY
Home Pride warrants its Lock Down Anchor System (HP LDS) against defects
designedand approved for use in the State of Florida. This product.is
not be reused,or reinstalled at any other location. If used in violation
In workmanship and material at the she of its initial installation. The HP LDS is specifically
not approved for use and should not be used outside the State of Florida. This product must
of this Warranty or not installed in accordance with installation instructions, all written and
Implied warranties are void and,disciaimed. HP LDS products which are found to have defects will be repiaced,or repaired at Home Pri e s option. T is Express Warranty
Is limited to:replacement of product only and does not cover any laborior installations costs. When the product is replaced, all Warranty rights are extinguished. This
Warranty is only to the benefit of the original purchaser and is nottransferable.
There,are no other warranties (express orimplied) whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home
Pride disclaims any and all otherimplied warranties, Including (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose
to the extent allowed by law and any Implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty.
These limitations shall be enforceable to the extent permitted by law. I
HP LDS products which are examined and are found notto be defective will be returned to user and all costa associated with examination of the anchor product will be
incurred by the user. The user is responsible for all maintenance of the HP LDS product including regular monitoring of stability and integrity of HP LDS products.
For a warranty claim, contact your distributor or Home Pride Inc. at