HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSSCANNED
By
8� Lucie r.wf p%
HOME PRIDE
Manufactured Housing- Installation Instructions
Lock Down Anchoring System
Wind Zones 2 & 3
For The State Of
]File Copy
I -Beam Connection
NOTE: If one or more of the following conditions exist contact a Registered Professional Engineer.
• Location is within 1,500' of the coastline.
• Pier Height exceeds 48".
• Roof eaves exceeds 16".
• Sidewall height exceeds 96".
• Length of home exceeds 76'.
REQUIREMENTS FOR USE II
1. The use of the Lock Down Anchoring System requires sidewall vertical ties at no greater than 5'4" on center.
2. Centerline anchors to be sized according to the soil torque conditions.
3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor.
4. Sidewall vertical ties can use 4' anchors in soil type 413.
S.
6.
Homes requiring 4 Lock Down Anchor
assembiies require the longitudinal
and lateral strut on each anchor. All
struts must be installed towards the
center of the home.
Homes requiring 6 Lock Down Anchor
assemblies only require longitudinal
struts on the 4 corner positions. The
two center positions only require a
lateral strut. All struts must be installed
towards the center of the home.
Facing the home
LEFTCORNER
L.p
Facing the home Facing the home
LEFT CORNER CENTER
Facing the home
RIGHT CORNER
Facing the home
RIGHT CORNER
tudinal
7. The placement of the corner systems should be at a sidewall vertical tie that falls no more than 11' and no less than 5' from the end of the.house on
each corner.
1. H 0.M E__ _.P R I D E
NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED:
Wind Zones 2 & 3 with roof pitch 6/12 or less.
• Single or Double section homes 30' to 52 in length (excluding hitch) 4
• Single or Double section homes greater than 52' to 76' in length (excluding hitch) 6
NOTE: Roof pitches greater than 6/12 will require additional systems, contact Home Pride, Inc. for assistance.
NOTE: Homes less than MY — Lock Down System should not be used.
NOTE: Home manufacturers may provide a placement chart for specific models in their installation manual. The manufacturer's placement chart supersedes the
chart below.
ANCHOR ASSEMBLY PLACEMENT
Using 4 Anchor Assemblies
Lock Down Anchor Assembly Components List
1. Ground Anchor with Strut Attachment Cap
2. Stabilizer
3. Lateral Strut
4. Longitudinal Strut
5. Beam Clamp Assembly
Lock Down Anchor Assembly 'Installation Instructions
Using 6 Anchor Assemblies
r �l r
lil"- IIA _.. - ..
The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor
and align .with a sidewall vertical strap. Install this anchor at a slight angle, not to exceed
15 degrees. This assembly includes a stabilizer plate that is installed with the anchor and
attached with.a U-bolt and two nuts. The stabilizer plate should be driven into the ground
when the anchor is about 2/3 installed. Attach the stabilizerto the anchor shaft using the
U-bolt and.nuts then complete the install of the anchor until the strut attachment cap is
flush to the.ground or slightly recessed into the ground, no more than Y". The Strut
Attachment Cap should be installed within Y." or flush to the top of the stabilizer plate.
(See illustration to the right.)
NOTE: State'of'Florida allows a 2' pilot holes to be drilled to assist anchor installation in extremely hard soil conditions. If this process is used during installation
of the Ground Anchor with Strut Attachment Cap the soil must be placed back in the pilot hole and compacted at 6" intervals. This process should take place
when -the anchor is 8"-10" from fully installed — allowing room for the soil to be.placed back in the pilot hole and properly packed.
D E 2.
Once the ground anchor assembly is fully installed, attach longitudinal and lateral struts according to the diagram under anchor assembly placement (page 1.). The
lateral arm fasteners are to be installed tightly (nuts and bolts). IThe Beam. Clamp assembly has two•holesfor the bolt and nut placement. Depending on the width of
the beam; the corresponding hole should be used that pushes the front of the metal plate as close as possible to the upright of the beam. See the illustration on page
2, #5.
Lateral struts should be Installed in line with the center anchor head and attached at the top of the I-beam.
Lateral strut angles must fall within 10 degree minimum - 60 degree maximum. Longitudinal strut angles must fall within 10 degree minimum - 50 degree maximum.
CerigitodlnalSttat _
Altt+ehedPeMt
Facing'the hu iie LEFT CORNER
Wteral Sttui:
AttathedMint
sldawallstrap
Conneetlen
Longitudinal Sttut
Attached Point.
Facingihohome RIGW CORNER
After the Lock Down Anchor Assemblies have been fully Installed and all permiter anchors and straps fully installed and tightened- each strut has 4.self.tapping
screws that must be installed as the final.step. Predri lied, holes are provided on the outer strut indicating placement. If the predrilled holes cannot be accessed,
install the screws as close to the predrilled holes as.possible = m(aking sure they are tapping into the inner strut.
The Lock Down Anchoring System should only be used for homes in the state of Florida. This anchoring system is not designed, tested or approved for use in any
otherstate.
Contact Home Pride Inc. 276-466-0502 or at.c6ntectusL@hr)a6cho'rs.com for any questions concering this product.
Legacy Engineering listing # 113
Notes:
PRODUCT WARRANTY
Home Pride warrants its Lock Down Anchor System (HP LDS) against defects in workmanship and material at the site of its initial installation. The HP LDS is specifically
designed and approved for use in the, State of Florida. This product is•notapproved for use and should not be used outside the State of Florida. This product must
not be reused or reinstalled at any other location. If used In violation of this Warranty or not installed in accordance with installation instructions, all written and
implied warranties are void and disclaimed. HP LDS products which are found to have defects will be replaced or repaired at Home Pride's option. This Express Warranty
is limited to replacement of product only and does not cover any labor or installations costs. When the product is replaced, all Warranty rights are extinguished. This
Warranty is only to the benefit of the original purchaser and is not transferable.
There'are no other warranties (express or implied) whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home
Pride disclaims any and all other implied warranties; including (but not limited to) warranties of habitability, workmanship, materialsand fitness for a particular purpose
to the extent allowed by law and any implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty.
These limitations shall be enforceable to the extentpermitted by law.
HP LDS.products whictrare examined and'are found not to be defective will be returned to user and all costs associated with examination of the anchor product will be
incurred by the user. The user is responsible for all maintenance; of the HP LDS product including regular monitoring.of stability and integrity of HP LDS products.
For a warranty claim, contact your distributor or Home Pride Inc. at 15100 Industrial Park Road, Bristol, Virginia, 24202.
3. H0'ME PRIDE