HomeMy WebLinkAboutMANUFACTURED HOME INSTALLATION SPECIFICATIONSCANNED By Manufactured Home Installation Specifications _ (Must be completed and submitted with your application) Applicant .kekdl1& , TAC Address o it tx w e-mme, 1o,m NJ Manufacturers Name Permit # L- ck5 - I �er�e �I �tq ►� 6 Roof Zone Wind Zone 3 No. of Sections �_ Width (a Length _ Year ISO Serial # Tr 12 6 I - 0 a(P H - 1320 1 �,U Installation Standard Used (check) Manufacturers Manual 15C-1 I Site Preparation Debris and Organic Removal es Water Drainage: Natural Swale Pad Other Foundation Load bearing soil density 9SQQ Or assumed 1,000 psf Footing type: Poured in place X- Portable Mainrail frame block: Size r2 (I Placement o.c. Perimeter blocking: Size � Number Location Ridge beam support: Number Size Location Center line blocking: Number AIIA Size Location Special supports required (fireplace, bay window) Yes No Mating of Units: Mating gasket Type used AIJA Fasteners: Roof Type VF' g 0.0. Endwall Type O.C. Floors Type o.c. Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Anchors: Type 6,000 3,150 Page# Height of Unit (top of foundation to frame):4 Page # Angle of straps M9 Ver PUA, ( Page # Number of frame ties O Spacing o,c, Page # Number of over -roof ties (if required) Page # Number of sidewall anchors Zone H Zone III �� Page # Number of centerline anchors Number of stabilizers Page # Vents required for underpinning (Is11150 sf floor area): No. ' 1 Page # .Vile Date: Revised 7/22/2014 Prepared by: Tlaws EXHIBIT "B" EXHIBIT "B" n ;Lighter than concrete,. saves on labor. , , Largely pads1 increase -spacing, saving time andmaterial. + 'Made from:recycled materials.' t + Easily stackable for larger -pad area and wider pier spacing. Multi stack for 5;,sq: ft. & 6-`sqA. ~ Pad Beaming Capacity ABS Pad Part# iD00 itis. 1500 lbs. 2000 lbsD30001be. Size Soil Soil Soil 16" x 1'8"- 2 Sq. Ft. 59300 2,000 lbs. 3,600 lbs. 4,000 lbs. 6,000 lbs. 288 Sq. In, 16" x 22.5" -'2.5 Sq. Ft: 59301 2,500 lbs. 3,150 lbs. 5,000 lbs. 7,500 lbs. 360 Sq., In. 17" x 2511- 3 Sq. Ft, 59302 3,600 lbs. 4,500 lbs. 6,000 lbs. N/A 432 Sq. In. 24" x 24" - 4 Sq. Ft. 59303 4,000 lbs. 6,000 ibs. 8,0601bs. N/A $76 Sq. In. 5 32" X 22.51'(See 1 below) 3 X 59301 5,600 Lbg. 7,500 lbs. 10,060 Lbs.. 5 Sq. Ft. - 720 Sq. In. F 34:4 X 25 , (See 2 below) 3 X 59302 6,000 Lbs. 9,000 lbs. 12,000 Lbs 6 Sq. Ft. - 864.Sq. Iri. r * Concrete Block.rated"�'8000.Itis 'Doubleblock any -higher loads., -1.` The 32 X 22.5 Pyramid configuration uses 2 =16 X 22 5.pads placed side by side with 1-10 X'22.5 pad on top in the opposite direction. ° k - 2.' The 34.4 X 25.4.Pyramid configuration uses 2 -17.2 .X 25.2 placed side by side with A —17.2 X 25.2 Pad on top in y.the opposite direction. r 5 Single "Stack ' .:Course F Double Stack `Course Multi Pad Layout,