HomeMy WebLinkAboutinstallation instructionsHOMiEr'PRIDE
Manufactured H,, ousing Installation Instructions
Lock Down Anchoring System
Wind Zones 2 & 3
For The State Of
C a
Anchor &
Stabilizer
i
I
I
I
i
1-Beam Connection
00
o0
o
ORO
Lateral/Longitudinal
10
NOTE: If one or more of the following condition's exist contact a Registered Professional Engineer.
• Location is within 1,500' of the coastline.1
• Pier Height exceeds 48".
• Roof eaves exceeds 16".
• Sidewall height exceeds 96".
• Length of home exceeds 76'.
REQUIREMENTS FOR USE
1. The use of the Lock Down Anchoring System requires sidewall vertical ties at no greater than 5'4" on center.
2. Centerline anchors to be sized according to the soil torque conditions.
3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor,
4. Sidewall vertical ties can use 4' anchors lin soil type 4B.
Facing the home Facing the home
LEFT CORNER RIGHT CORNER
5. Homes requiring4 Lock Down Anchor
assemblies require the longitudinal i
and lateral strut on each anchor. All I
struts must be installed towards the
center of the home. -
1.
Et•, t:'��s ty"+.. .�: •���t :'`v+7,' .;'��,.5., 'F iti•�!`ahi I�
♦ .n "' ::i��i`. ..;,�Y•�• •.try. \j'�i.•`r i.w�'�� �i ���• '�1)J'
Facing the home Facing the home Facing the home
LEFTCORNER CENTER RIGHT CORNER
I
Homes requiring 6 Lock Down Anchor)
assemblies only require longitudinal I , •I T "-1 11
%�
P Y q _.
struts on the 4 corner positions. TheI
two center positions only require a
lateral strut. All struts must be Installed°'
towards the center of the home.
�� zl k ;� � r: �. Z � �i�iC� t� : "� r� in 7 }�R In r�11�`^ y •.
y �, t Cat"�r���"R".1 � it� 4,;: t y �. `�•3'3;•cY?S? � "'{��.'S tl��"� <4++ � •..i'� '` � f
The placement of the corner systems should be at a sidewall vertical tie that falls no more than 11' and no less than 5' from the end of the house on
each corner.
i
F
H.0 M_E_, P. R 10 E
I
I
NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED:
i
Wind Zones 2 & 3 with roof pitch 6/12 or less.
• Single or Double section homes 30' to 52 in length (excluding hitch) 4
• Single or Double section homes greater thanl52' to 76' in length (excluding hitch) 6
NOTE: Roof pitches greater than 6/12 will require adiitional systems, contact Home Pride, Inc. for assistance.
NOTE: Homes less than 30' — Lock Down System should not be used.
I '
NOTE: Home manufacturers may provide a placement chart for specific models in their installation manual. The manufacturer's placement chart supersedes the
chart below.
ANCHOR ASSEMBLY PLACEMENT i
Using 4 Anchor Assemblies
L� lal h ICI. hJ sa■■� __
Lock Down Anchor Assembly Components List
1. Ground Anchor with Strut Attachment Cap
2. Stabilizer
3. Lateral Strut
4. Longitudinal Strut
S. Beam Clamp Assembly !
Lock Down Anchor Assembly_Installation Instructions
Using 6 Anchor Assemblies
The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor
and align with a sidewall vertical strap. Install this anchor at a slight angle, not to exceed
15 degrees. This assembly Includes a stabilizer plate that is installed with the anchor and
attached with a U-bolt and two nuts. The stabilizer plate should be driven into the ground
when the anchor is about 2/3 Installed. Attach the stabilizerto the anchor shaft using the
U-bolt and nuts then complete the install of the anchor until the strut attachment cap is
flush to the ground or slightly recessed Into the ground, no more than K". The Strut
Attachment Cap should be installed within X" or flush to the top of the stabilizer plate.
(See illustration to the right.)
NOTE: State of Florida allows a 2' pilot holes to be drilled to assist anchor installation in extremely hard soil conditions. If this process is used during installation
of the Ground Anchor with Strut Attachment Cap the soil must be placed back in the pilot hole and compacted at 6" intervals. This process should take place
when the anchor is 8"-10" from fully installed allowing room for the soil to be placed back in the pilot hole and properly packed.
HOME PRIDE 2.
M
Once the ground anchor assembly is fully installed, attach longitudinal and lateral struts according to the diagram under anchor assembly placement (page 1.). The
lateral -arm fasteners are to be installed tightly (nuts and bolts). The Beam Clamp assembly has two holes for the bolt and nut placement. Depending on the width of
the beam, the corresponding hole should be used that pushes the front of the metal plate as close as possible to the upright of the beam. See the illustration on page
2, #5.
Lateral struts should be installed in line with the center anchor head and attached at the top of the I-beam.
Lateral strut angles must fall within 10 degree minimum ; 60 degree maximum. Longitudinal strut angles must fall within 10 degree minimum - 50 degree maximum.
wngitudimistm
'AttothedPeint
Facing thtr hoineLEFTCORNER
' Lateral Unit
AttachedPbint
tonwIlbh
Lwghudittal strut
Attached Point
�vral Strut
chodpolnt
trap
Ion
After the Lock Down Anchor Assemblies have been fully installed and all permiter anchors and straps fully installed.and tightened —each strut has 4-self tapping
screws that.must be installed as the final step. Predri}led holes are provided on the outer strut indicating placement. If the predrilled holes cannot be accessed,
install the screws as close to the predrilled holes as possible - making sure they are tapping into the inner strut.
The Lock Down Anchoring System should only be usedor homes In the state of Florida. This anchoring system is not designed, tested or approved for use in any
other state.
Contact Home Pride Inc. 276-466-0502 or at contactus@hoanchors.com for any questions concering this product.
Legacy Engineering listing # 113
Notes:
PRODUCT WARRANTY
Home Pride warrants Its Lock Down Anchor System (HP LDS) against defects in workmanship and material at the site of its initial installation. The HP LDS is specifically
designed and approved for use in the State of Florida. This product is not approved for use and should not be used outside the State of Florida. This product must
not be reused' or reinstalled at any other location.) If used in violation of this Warranty or not installed in accordance with installation instructions, all written and
implied warranties are void and disclaimed. 'HP LDS products which are found to have defects will be replaced or repaired at Home Pride's option. This Express Warranty
Is limited to.replacement of product only and does rot cover any labor or installations costs. When the product is replaced, all Warranty rights are extinguished. This
Warranty is only to the benefit of the original purchaser and is not transferable.
There are no other warranties (express or implied) whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home
Pride disclaims any and all other implied warranties,lincluding (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose
to the extent allowed by law and any Implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty.
These limitations shall be enforceable to the extentipermitted by law.
HP LDS products which are examined and are found not to be defective will be returned to user and all costs associated with examination of the anchor product will be
incurred by the user. The user is responsible for alllmaintenance of the HP LDS product including regular monitoring of stability and integrity of HP LDS products.
For a warranty claim, contact your distributor or