FIELD DENSITY TESTS OF COMPACTED SOILS
DATE: 01/22/05 oRDERNo: 05-0659 PERMIT NO. e5nOC-
CLIENT: B & D GRADING, INC.
PROJECT: PROPOSED RESIDENCE BUILDING PAD LOT 126 RESEW
A. .,. ZZ 1 UI AAAYnlTn?-= nIDPJP QT T1 Id -11- r(IT IN rV VUORMA ' erra
I
MATERIAL DESCRIPTION:
- j 6' - 7 — _1=
BROWN SAND �! �f i�'IIR!ir
I n 1 it
LOCATION: N.E. CORNER OF PAD
' > `
I �� ��, .
LOCATION: S.W. CORNER OF PAD
LOCATION: S.E. CORNER OF PAD
LOCATION:
LOCATION:
LOCATION:
FIELD DENSTTj
Y METHOD AS.T.M.
D-2922
DRY DENSITY P.C.F. IN THE I =
107.1 I
107.7
107.2
% MOISTURE
10.1
9.7
8.2
% COMPACTION IN THE FIELD
98.1 I
98.7
98.2
% COMPACTION REQUIREMENT
95%
GS
PROCTOR VALUE, P.C.F.
109.2
OPTIMUM MOISTURE, %
12.1
LABORATORY NO.
P-1630
DEPTH IN INCHES
12
PROCTOR A.S.T.M D-1557 METHOD
REMARKS: SOIL NOT TESTED BELOW FOOT
'