Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEFF,OR` LrwTy 1 D A Project Name: Project Address: Permit #: Planning & Buildir 2300 Virginia Aven Certification for Patel Residence, SR AIA - PARCEL I Occupa evelopment Services Department ���' & Code Regulations Division `.%� rF1?=B�!G,Qr'�,� e, Fort Pierce,,.,FL 34982 - (772) 462-155 es- igh Load Compliance = 72477 lewild Hutchinson Island, LLZz # 1414-310-0005-000-1AiA o. R1°N iType: R3 Construction Type: V-���1/1101"L`,�1 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • 'Submit (.2) copies for residential, (3) copies for co martial with all permit applications involving the following: o New Residences (single or multi -family) - c. Residential Addition �j%i (�-- Any accessory structure requiring a builc ing permit Ql -o, Any non-residential structure. FILEC,, OPYT:so-�-.c Note: Form not required for interior renovations p ovided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (c mplete all that apply) 1. DESIGN CODE: Florida Residential C9de 2. Structure Designed as (che5k one): ✓Encl 3. Risk Category: _I 11 III IV 4. Design Wind Velocity ) Vmph _ S. Mean Roof Height 4 r • Z ft Edition with 20 11 Supplements using ASCE 7-10 Partially Enclosed Open Exposure Category: B C D ✓LRFD End Zone Width: ft Pitch: _:12 Parapet: 3 ft 6. Components & Cladding Design Pressures Used: (PSF, based on SOS @ 15'MRH, clearly label on all plan openings): 22.31 22. 3 I 22. 31 t 1 Zone 1:--R- R Zone 2 _ 2•0L Zone 3: -1 3' •S Zone 4- 5 38 Zone 5:-ba13 Garage: 7. Design Loads: Floor: ) PSF Roof/Dead ' — PSF Roof/Live: 3u Balcony: jdJ PSF Dock: PSF Deck: PSF Stairs: �I y O�. PSF Fence: PSF Railings: PL�PSF S. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Wh Not: 1-o wS/ %C -,a I A n S e o it Ll`L /►? •.mac,-{- 9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2 �� PSF Soil Test Reports Submitted? v Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief; the attached plans & specifications have been designed to comply with the applic:ab!F, structural portions of the ibuilding codes currently adopted and enforced by St. Lucie County. I also certify tnaf si,-u&ural elements depicted on these plans provide adequate resistance to the design forces -specified: Print Name Cert # & Co. Cert Auth. Pima• r. -f eAtssie- LL G 28L ~ Signature, Date, and Seai Zl 1 3 �w 6 �1`S to • �f G Company Name & Address 0 SLCCDV form # 020-12 Revised 3/15/12 (JS)