Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 FLORIDA ENERGY EFFIC ENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business 6nd Professional Regulation - Residential Performance Method Project Name: A private Residence Builder Name: Street: un0 Qrr�� Permit Office: St. Lucie County g` � � City, State, Zip: Hutchinson Island , FI , Permit Number: Owner. Jurisdiction: 661000 Design Location: FL, Fort Pierce NV OS 1. New construction or existing New (�jrom Plans) 9. Wall Types (6692.4 sqft.) Insulation Area 2. Single family or multiple family Singletfamily a. Concrete Block - Int Insul, Exterior R=4.1 6188.40 ftz b. Frame - Steel, Exterior R=11.0 273.00 f12 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Exterior R=13.0 231.00 ft2 4. Number of Bedrooms 4 d. WA R= ft2 10. Ceiling Types (2599.0 sgft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=30.0 2599.00 ft2 6. Conditioned floor area above grade (ft2) 5100 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ;y;• ft 11. Ducts R ft2 7. Windows(1373.0 sqft.) Description Area a. Sup: Main, Ret: Main, AH: Main 6 146 a. U-Factor: Dbl, U=0.65 1373.00 ft2 b. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 121 SHGC: SHGC=0.30 c. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 294 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.8 SEER:19.00 b. Central Unit 46.4 SEER:18.00 c. U-Factor. NIA ft2 c. Central Unit 47.0 SEER:18.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 41.0 HSPF:8.20 SHGC: b. Electric Heat Pump 49.0 HSPF:8.50 Area Weighted Average Overhang Depth: 5.198 ft. c. Electric Heat Pump 49.1 HSPF:8.50 Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 85 gallons 8. Floor Types (5100.0 sgft.) Insulation Area EF: 0.960 a. Raised Floor R=19.0 3027.00 ft2 b. Conservation features b. Raised Floor R=0.0 2073.00 ft2 None c. NIA R= ft2 15. Credits Pstat Total Proposed Modified Loads: 80.44 PAS c Glass/Floor Area: 0.269 S Total Standard Reference Loads: 116.63 t hereby certify that the plans and specifications covered by Review of the plans and j'4UE ST,g1� this calculation are in compliance with the Florida Energy , specifications covered by this Code. calculation indicates compliance ��' ��,,''1 '`,�.•� with the Florida Energy Code. it rn,,,�•; - :;%;;:,u ;� �O PREPARED BY. _ Before construction is completed r� DATE: A _ this building will be inspected for �1 compliance with Section 553.908 I hereby certify that this building, as de ' ned, i in compliance Florida Statutes. with the Florida Energy C d . COD y�v OWNER/AGENT: _ ��. BUILDING OFFICIAL: ____ DATE: 7-$ , DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #3 may be undersized. Size of 49.' was increased to 51.6 for simulation. Please review the Manual J8 report.- Cool sys #2 maybe undersized. Size of 46.4 was increased to 46.4 for simulation. Please review the Manual J8 report. 8/6/2012 11:15 AM EnergyGaugeQD USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 PROJECT Title: A private Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 5100 Lot # Owner. Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: St. Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: 661000 Whole House Fan: City, State, Zip: Hutchinson Island , Family Type: Single-family Fl , New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1307 13723.5 2 Block2 1720 18060 3 Block3 2073 21766.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1307 13723.5 Yes 1 1 Yes Yes Yes 2 1st Floor 1720 18060 No 2 1 1 Yes Yes Yes 3 2nd Floor 2073 21766.5 No 3 3 1 Yes Yes Yes FLOORS # Floor Type Space) Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor MI in _ _ 1307 ft2 19 0 0 1 2 Raised Floor 1st loor ---- _ 1720 ft2 19 0 0 1 3 Raised Floor 2nd Floor — 2073 ft2 0 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Flat Concrete 2608 ft2 110 ft2 Light 0.96 No 0.9 No 30 4.8 ATTIC V # , Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvinted 0 2599 ft2 N N 816/201211:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 CEILING # Ceiling Type I Space R Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (UnventeQst Floor 30 526 ft2 0.11 Wood 2 Cathedral/Single Assembly (Unvent l nd Floor 30 2073 ft2 0.11 Wood WALLS Omt Adjacent Cavity To Wa1LJyp Space - ue Width Ft In Height Ft In Sheathing Framing Solar Below area RAW,* Fracion-Absor-GmdeJ 1 N Exterior Frame - Steel Main 11 26 10 6 273 ft2 0 0.75 0 2 N Exterior Concrete Block - Int Insu Main 4.1 5 10 6 52.5 ft2 0 0.75 0 _ 3 NE Exterior Concrete Block - Int Insu� Main 4.1 15 8 10.5 164.5 W 0 0.75 0 _ 4 E Exterior Concrete Block - Int Insul Main 4.1 26 6 10 6 278.25 ftz 0 0.75 0 _ 5 -6 E SE Exterior Exterior Concrete Block - Int Insul Main Concrete Block - Int ins II Main 4.1 4.1 51 12 0 10 10 6 6 52.5 ft2 126 ft2 0 0 0.75 0.75 0 0 _ 7 S Exterior Concrete Block - Int Ins�l Main 4.1 22 8 10 6 238 ft2 0 0.75 0 _ 8 SW Exterior Concrete Block - Int Instil Main 4.1 7 6 10 6 78.75 ft2 0 0.75 0 -9 W Exterior Concrete Block - Int Instil Main 4.1 24 6 10 6 257.25 ft2 0 0.75 0 _ 10 11 NW N Exterior Exterior Concrete Block - Int Insul Main Concrete Block - Int Insul 1st Floor 4.1 4.1 7 10 4 6 10 10 6 6 77 ft2 110.25 ft2 0 0 0.75 0.75 0 0 12 NE Exterior Concrete Block - Int Ins 11st Floor 4.1 16 8 10 6 175 ft2 0 0.75 0 13 E Exterior Concrete Block - Int Ins 11st Floor 4.1 48 8 10 6 511 ft2 0 0.75 0 14 E Exterior Concrete Block - Int Ins 11 st Floor 4.1 9 8 10 6 101.5 ft2 0 0.75 0 _ 15 SE Exterior Concrete Block - Int Ins 11st Floor 4.1 22 9 10 6 238.875 ft 0 0.75 0 _ 16 S Exterior Concrete Block - Int Insul 1st Floor 4.1 29 4 10 6 308 ft2 0 0.75 0 _17 S Exterior Concrete Block - Int 141 1st Floor 4.1 11 10 6 115.5 ft2 0 0.75 0 _ 18 19 S SW Exterior Exterior Concrete Block - Int Insul 1st Floor Concrete Block - Int Insul 1st Floor 4.1 4.1 6 16 6 10 14 6 6 63 ftz 239.25 If 0 0 0.75 0.75 0 0 _ 20 _21 W W Exterior Exterior Concrete Block - Int Insul 1st Floor Concrete Block - Int Insul 1st Floor 4.1 4.1 29 7 4 6 10 10 6 6 308 ft2 78.75 ft2 0 0 0.75 0.75 0 0 _22 N Exterior Concrete Block - Int 1+12nd Floor 4.1 10 6 10 6 110.25 ftz 0 0.75 0 _23 N Exterior Concrete Block - Int In$ul2nd Floor 4.1 5 0 10 6 52.5 ft2 0 0.75 0 24 25 26 _ 27 NE NE E E Exterior Exterior Exterior Exterior Concrete Block - Int Inlsul2nd Floor Concrete Block - int Insul2nd Floor Concrete Block - Int Insul2nd Floor Concrete Block - Int Inlsul2nd Floor 4.1 4.1 4.1 4.1 12 20 41 21 0 8 6 8 10 10 10 10 6 6 6 6 126 ft2 217 ft2 435.75 ft2 227.5 W 0 0 0 0 0.75 0.75 0.75 0.75 0 0 0 0 _28 _29 _ 30 E SE SE Exterior Exterior Exterior Concrete Block - Int InlIsul2nd Floor Concrete Block - Int Irisul2nd Floor Concrete Block - Int Irjsul2nd Floor 4.1 4.1 4.1 28 10 12 0 0 10 10 10 6 6 6 294 ft2 105 ft2 126 ft2 0 0 0 0.75 0.75 0.76 0 0 0 _31 _32 S S Exterior Exterior Concrete Block - Int Insul2nd Floor Concrete Block- Int Insul2nd Floor 4.1 4.1 22 15 4 4 10 10 6 6 234.5 ft2 161 ftz 0 0 0.75 0.75 0 0 _ 33 SW Exterior Concrete Block - Int I Insul2nd Floor 4.1 5 0 10 6 52.5 ft2 0 0.75 0 34 SW Exterior Concrete Block - Int 1 i sul2nd Floor 4.1 12 6 10 6 131.25 ft2 0 0.75 0 _35 SW Exterior Concrete Block - Int Insul2nd Floor 4.1 7 6 10 6 78.75 ft2 0 0.75 0 _ 36 V1/ Exterior Concrete Block - Int Insul2nd Floor 4.1 25 10 6' 262.5 W 0 0.75 0 _ 37 W Exterior Concrete Block - Int Irsul2nd Floor 13 22 10 6 231 ft2 0 0.75 0 8/61201211:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 N Cl N Ch m _ CD c — (o c D 0) 10 CD O O N a 0 _ A 0 N A -a 0 O �O3 of 7 idZ W N O 00y m CNh A W N s O CO O V 0 11 A W N •+ O m m m m m m m r mmmmmZ m mm m zZ 3 N W A W O N W N W N V N 01 N N N > W -� W N O — W -� (0 -� W s Ch s 0 -a W -a W -' -► -� s O W V V O cn W N CC C �� Z Ow O7 N - - - N N - SI N 01 - - - C7 CI Ow d N N Ow Ow p1 - N N Ow N 61 m 0 0 0 0 0 0 0 O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 c 0 c 0 c 0 c 0 c 0 0 0 0 0 c 0 c 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a a a a a c a c a c a c a a a c a c a c a c a a c a c a c a c a c c c a c a c a c a c a c a c a c a c a c a c a c a o 0 CD N CD N CD N N N .+ (�D N N N N N N a a a (D CD CD CD CAD (D (D r. o. _. CD G � or— 0 WOW N (mA (ft N N y 0 0 0 0 0 0 0 0 0 0 y W (mA ( N !/mw (4 0 y N (mp N N 0 C = O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O y Ch 0 O 0 W 0 N a 0 in CA Ow iA in N in Ch Ch Ch O CA O O Ch 6 O 6 (Am O 6 W O O 6 O ih p 0) in CA O O W Uw = 0 (A N N (A N p1 W Ch W Ch 00 Ch Ch O w 0 01 (i Ul �, v o mZ 0 S =v O iw O w O w O is O is O w O w O w O w O w O is O w O w O w O w O w O w O w O w O w O is O w O w O w O is O w O is p w O w O w O w O (a O w O M CO) N 0 0 = O CD C2 m y O Ch A. W D CD = cNXE U Zn O W O O O OD V O M CA O O 00 Ch .O O = O C -+ -' ''� -+ -y' -• -• O O O p O p CyDC p O Oy O Oyy O co p O O O o � .y. yO .Oµ y y0y O c,O O O O O O O O O O O O O O c,O 0 v 7 > > 7 7 7 = 7 7 7 7 _O = 7 = 7 7 7 7 7 7 = 7 7 7 = m (n 3' W .�► O O A O O O A O O O O O O O OO O O O ON O O CD N go O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O EF 7 5 7 7 > > 7 7 = = 7 3 7 7 7 > S. = 7 7 7 7 7 > > 7 = 7 7 7 C = _ v o 0 0 0 0 0 v 0 o v 0 0 0 0 o v o 0 v v 0 0 v 0 0 v 0 0 v v v v O C� G-i 0� 0� 0� A-i G� 4p� C-pi 0� Gp� 0p� 0� 0� 6p� •Cp� 4� O� 0� 11� flw 0p� p� 4� 0� Cw C� C� C� N C� 0� 7 '•n = CD CD CaD cD m m fD cD tU cD cD CD (n m (p CD m m y •0p� fD CP m m CA 0 y m m y m CG m a C a a a a a asaaa a a a a a a a a aasCaaa O. CL m = y y y Vw 0 a !A CL y y CA y y (A CA y Caa y 0 y W y y (A to 0 y 0 y (A (A (A (A (A y y Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z z Z Z O 7 O = O _ O _ O = O 7 O = O 7 O = O _ O _ O _ O _ O _ O _ O _ O _ O _ O _ O _ O _ O = O 7 O = O = O _ O = O _ O _ O = O _ O = O 7 m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m = (Q GARAGE # Floor Area Ceiling Are Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 484 ft2 100 ft2 64 ft 10.5 ft 3 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess i 0.000300 I 4013.2 220.32 414.34 0.2696 4.4965 HEATING SYSTEM # System Type Sub pe Efficiency Capacity Block Block Ducts 1 2 3 Electric Heat Pump Electric Heat Pump Electric Heat Pump NoneII None Non i ` HSPF: 8.2 41 kBtu/hr 1 HSPF: 8.5 49 kBtu/hr 2 HSPF: 8.5 49.1 kBtu/hr 3 sys#1 sys#2 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit Central Unit Central Unit Non Non No7 SEER: 19 35.8 kBtu/hr 1074 cfm 0.75 1 SEER: 18 46.4 kBtu/hr 1392 cfm 0.75 2 SEER: 18 47 kBtulhr 1410 cfm 0.75 3 sys#1 sys#2 sys#3 II HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.96 85 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None I ft2 DUCTS V # — Supply — Location R-Value Area — Return — Air Percent Location Area Leakage Type Handler CFM 25 Leakage ON RLF HVAC # Heat Cool 1 2 3 Main 6 146 ft2 1st Floor 6 121 ft2 Attic 6 294 W Main 1st Floor Attic 24 ft2 Default Leakage Main (Default) (Default) % 5 ft2 Default Leakage 1st Floor (Default) (Default) % 15 ft' Default Leakage 2nd Floor (Default) (Default) % 1 1 2 2 3 3 8/6/2012 11:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Feb Mar kiMar A r Apr Ma May Jun Jun Jul Jul Au Aug Se Sep Oct Oct Nov Dec Dec Venting Jan X NovV Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/6/2012 11:15 AM Energy auge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 FORM 405-10 ADDRESS: Florida Code Compliance Checklist Florida Departure t of Business and Professional Regulations Residentiall Whole Building Performance Method PERMIT #: Hutchinson Island, FI, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. E Windows Recessed lighting IC -rated as meeting ASTM 283. and doors I= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: / gasketed doors & outdoor combustion air. Must complete envelope li leakage report or visually verify Table 402.4.2. 1 Thermostat & 403.1 At leg Ist one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet�the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the pnmery air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing be ducts. cavities shall not used as supply Water heaters 403.4 Heai trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 r + accessible manual OFF switch. Mechanical 403.5 Homes designed. to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. / No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Po.I pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or otter means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal 4/16/13). Heat heaters efficiency=78% (82% after pump pool miplmum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special / equipment occasion cooling or heating capacity requires separate system or t/ variable capacity system. Electric heat >10kW must be divided into two or1 more stages. Ceilings/knee walls 405.2.1 �-19 space permitting. 8/6/2012 11:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software I Page 7 of 7 • 3 � a ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 69 The lower the Ene�gyPerformance Index, the more efficient the home. Hutchinson Island, Fl, 1. New construction or existing New (Fr, m Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single- mily a. Concrete Block - Int Insul, Exterior R=4.1 6188.40 ft2 b. Frame - Steel, Exterior R=11.0 273.00 ft2 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Exterior R=13.0 231.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=30.0 2599.00 ft2 6. Conditioned floor area (ft2) 5100 b. N/A R= ft2 7. Windows*" Description Area c. N/A R= ft2 a. U-Factor. Dbl, U=0.65 1 73.00 fe 11. Ducts a. Sup: Main, Ret: Main, AH: Main R ft2 6 146 SHGC: SHGC=0.30 b.'Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 121 b. U-Factor: NIA ft2 c. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 294 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a. Central Unit 35.8 SEER:19.00 SHGC: b. Central Unit 46.4 SEER:18.00 d. U-Factor: NIA ft2 c. Central Unit 47.0 SEER:18.00 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 5.198 ft. b. Electric Heat Pump 49.0 HSPF:8.50 Area Weighted Average SHGC: 0.300 c. Electric Heat Pump 49.1 HSPF:8.50 8. Floor Types Insulation Area 14. Hot water systems Cap: 85 gallons a. Raised Floor R=19.0 3027.00 ft2 a. Electric EF: 0.96 b. Raised Floor R=0.0 2073.00 ftz c. NIA R= f� b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: <2/ Address of New Home: /�z/z- /3 Date. _ City/FL Zip: -txE srgT�o.� fill xivi a w tr �oD WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "'Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. USA - FlaRes2010 Section 405.4.1 Compliant Software