HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10
FLORIDA ENERGY EFFIC ENCY
CODE FOR BUILDING CONSTRUCTION
Florida Department of Business 6nd Professional Regulation - Residential Performance Method
Project Name: A private Residence
Builder Name:
Street: un0
Qrr�� Permit Office: St. Lucie County
g` � �
City, State, Zip: Hutchinson Island , FI ,
Permit Number:
Owner.
Jurisdiction: 661000
Design Location: FL, Fort Pierce
NV OS
1. New construction or existing New (�jrom
Plans)
9. Wall Types (6692.4 sqft.) Insulation Area
2. Single family or multiple family Singletfamily
a. Concrete Block - Int Insul, Exterior R=4.1 6188.40 ftz
b. Frame - Steel, Exterior R=11.0 273.00 f12
3. Number of units, if multiple family 1
c. Concrete Block - Int Insul, Exterior R=13.0 231.00 ft2
4. Number of Bedrooms 4
d. WA R= ft2
10. Ceiling Types (2599.0 sgft.) Insulation Area
5. Is this a worst case? No
a. Cathedral/Single Assembly (Unvented) R=30.0 2599.00 ft2
6. Conditioned floor area above grade (ft2) 5100
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ;y;• ft
11. Ducts R ft2
7. Windows(1373.0 sqft.) Description
Area
a. Sup: Main, Ret: Main, AH: Main 6 146
a. U-Factor: Dbl, U=0.65
1373.00 ft2
b. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 121
SHGC: SHGC=0.30
c. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 294
b. U-Factor. N/A
ft2
12. Cooling systems kBtu/hr Efficiency
SHGC:
a. Central Unit 35.8 SEER:19.00
b. Central Unit 46.4 SEER:18.00
c. U-Factor. NIA
ft2
c. Central Unit 47.0 SEER:18.00
SHGC:
13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump 41.0 HSPF:8.20
SHGC:
b. Electric Heat Pump 49.0 HSPF:8.50
Area Weighted Average Overhang Depth:
5.198 ft.
c. Electric Heat Pump 49.1 HSPF:8.50
Area Weighted Average SHGC:
0.300
14. Hot water systems
a. Electric Cap: 85 gallons
8. Floor Types (5100.0 sgft.) Insulation
Area
EF: 0.960
a. Raised Floor R=19.0
3027.00 ft2
b. Conservation features
b. Raised Floor R=0.0
2073.00 ft2
None
c. NIA R=
ft2
15. Credits Pstat
Total Proposed Modified Loads: 80.44 PAS c
Glass/Floor Area: 0.269 S
Total Standard Reference Loads: 116.63
t hereby certify that the plans and specifications covered by
Review of the plans and j'4UE ST,g1�
this calculation are in compliance with the Florida Energy
,
specifications covered by this
Code.
calculation indicates compliance ��' ��,,''1 '`,�.•�
with the Florida Energy Code. it rn,,,�•; - :;%;;:,u ;� �O
PREPARED BY. _
Before construction is completed r�
DATE: A _
this building will be inspected for �1
compliance with Section 553.908
I hereby certify that this building, as de ' ned, i in compliance
Florida Statutes.
with the Florida Energy C d .
COD y�v
OWNER/AGENT: _ ��.
BUILDING OFFICIAL: ____
DATE: 7-$ ,
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #3 may be undersized. Size of 49.' was increased to 51.6 for simulation. Please review the Manual J8 report.- Cool sys
#2 maybe undersized. Size of 46.4 was increased to 46.4 for simulation. Please review the Manual J8 report.
8/6/2012 11:15 AM EnergyGaugeQD USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
PROJECT
Title:
A private Residence
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 5100
Lot #
Owner.
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
Permit Office:
St. Lucie County
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan:
City, State, Zip:
Hutchinson Island ,
Family Type:
Single-family
Fl ,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL ST LUCIE CO_INTL
2 39 90
70
75 722
62
Low
BLOCKS
Number
Name
Area
Volume
1
Block1
1307
13723.5
2
Block2
1720
18060
3
Block3
2073
21766.5
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
Main
1307
13723.5 Yes 1
1 Yes
Yes
Yes
2
1st Floor
1720
18060 No 2
1
1 Yes
Yes
Yes
3
2nd Floor
2073
21766.5 No 3
3
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space)
Perimeter Perimeter R Value
Area
Joist R-Value
Tile Wood
Carpet
1 Raised Floor
MI
in _ _
1307 ft2
19
0 0
1
2 Raised Floor
1st
loor ---- _
1720 ft2
19
0 0
1
3 Raised Floor
2nd
Floor —
2073 ft2
0
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials
Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Flat
Concrete
2608 ft2 110 ft2 Light
0.96
No 0.9
No 30
4.8
ATTIC
V # ,
Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1
No attic
Unvinted
0 2599 ft2
N N
816/201211:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7
CEILING
#
Ceiling Type I Space
R Value
Area
Framing Frac
Truss Type
1
Cathedral/Single Assembly (UnventeQst Floor
30
526 ft2
0.11
Wood
2
Cathedral/Single Assembly (Unvent l nd Floor
30
2073 ft2
0.11
Wood
WALLS
Omt
Adjacent Cavity
To Wa1LJyp Space - ue
Width
Ft In
Height
Ft In
Sheathing Framing Solar Below
area RAW,* Fracion-Absor-GmdeJ
1
N
Exterior
Frame - Steel Main
11
26
10
6
273 ft2
0
0.75
0
2
N
Exterior
Concrete Block - Int Insu Main
4.1
5
10
6
52.5 ft2
0
0.75
0
_ 3
NE
Exterior
Concrete Block - Int Insu� Main
4.1
15
8
10.5
164.5 W
0
0.75
0
_ 4
E
Exterior
Concrete Block - Int Insul Main
4.1
26
6
10
6
278.25 ftz
0
0.75
0
_ 5
-6
E
SE
Exterior
Exterior
Concrete Block - Int Insul Main
Concrete Block - Int ins II Main
4.1
4.1
51
12
0
10
10
6
6
52.5 ft2
126 ft2
0
0
0.75
0.75
0
0
_ 7
S
Exterior
Concrete Block - Int Ins�l Main
4.1
22
8
10
6
238 ft2
0
0.75
0
_ 8
SW
Exterior
Concrete Block - Int Instil Main
4.1
7
6
10
6
78.75 ft2
0
0.75
0
-9
W
Exterior
Concrete Block - Int Instil Main
4.1
24
6
10
6
257.25 ft2
0
0.75
0
_ 10
11
NW
N
Exterior
Exterior
Concrete Block - Int Insul Main
Concrete Block - Int Insul 1st Floor
4.1
4.1
7
10
4
6
10
10
6
6
77 ft2
110.25 ft2
0
0
0.75
0.75
0
0
12
NE
Exterior
Concrete Block - Int Ins 11st Floor
4.1
16
8
10
6
175 ft2
0
0.75
0
13
E
Exterior
Concrete Block - Int Ins 11st Floor
4.1
48
8
10
6
511 ft2
0
0.75
0
14
E
Exterior
Concrete Block - Int Ins 11 st Floor
4.1
9
8
10
6
101.5 ft2
0
0.75
0
_ 15
SE
Exterior
Concrete Block - Int Ins 11st Floor
4.1
22
9
10
6
238.875 ft
0
0.75
0
_ 16
S
Exterior
Concrete Block - Int Insul 1st Floor
4.1
29
4
10
6
308 ft2
0
0.75
0
_17
S
Exterior
Concrete Block - Int 141 1st Floor
4.1
11
10
6
115.5 ft2
0
0.75
0
_ 18
19
S
SW
Exterior
Exterior
Concrete Block - Int Insul 1st Floor
Concrete Block - Int Insul 1st Floor
4.1
4.1
6
16
6
10
14
6
6
63 ftz
239.25 If
0
0
0.75
0.75
0
0
_
20
_21
W
W
Exterior
Exterior
Concrete Block - Int Insul 1st Floor
Concrete Block - Int Insul 1st Floor
4.1
4.1
29
7
4
6
10
10
6
6
308 ft2
78.75 ft2
0
0
0.75
0.75
0
0
_22
N
Exterior
Concrete Block - Int 1+12nd Floor
4.1
10
6
10
6
110.25 ftz
0
0.75
0
_23
N
Exterior
Concrete Block - Int In$ul2nd Floor
4.1
5
0
10
6
52.5 ft2
0
0.75
0
24
25
26
_ 27
NE
NE
E
E
Exterior
Exterior
Exterior
Exterior
Concrete Block - Int Inlsul2nd Floor
Concrete Block - int Insul2nd Floor
Concrete Block - Int Insul2nd Floor
Concrete Block - Int Inlsul2nd Floor
4.1
4.1
4.1
4.1
12
20
41
21
0
8
6
8
10
10
10
10
6
6
6
6
126 ft2
217 ft2
435.75 ft2
227.5 W
0
0
0
0
0.75
0.75
0.75
0.75
0
0
0
0
_28
_29
_ 30
E
SE
SE
Exterior
Exterior
Exterior
Concrete Block - Int InlIsul2nd Floor
Concrete Block - Int Irisul2nd Floor
Concrete Block - Int Irjsul2nd Floor
4.1
4.1
4.1
28
10
12
0
0
10
10
10
6
6
6
294 ft2
105 ft2
126 ft2
0
0
0
0.75
0.75
0.76
0
0
0
_31
_32
S
S
Exterior
Exterior
Concrete Block - Int Insul2nd Floor
Concrete Block- Int Insul2nd Floor
4.1
4.1
22
15
4
4
10
10
6
6
234.5 ft2
161 ftz
0
0
0.75
0.75
0
0
_ 33
SW
Exterior
Concrete Block - Int I Insul2nd Floor
4.1
5
0
10
6
52.5 ft2
0
0.75
0
34
SW
Exterior
Concrete Block - Int 1 i sul2nd Floor
4.1
12
6
10
6
131.25 ft2
0
0.75
0
_35
SW
Exterior
Concrete Block - Int Insul2nd Floor
4.1
7
6
10
6
78.75 ft2
0
0.75
0
_ 36
V1/
Exterior
Concrete Block - Int Insul2nd Floor
4.1
25
10
6'
262.5 W
0
0.75
0
_ 37
W
Exterior
Concrete Block - Int Irsul2nd Floor
13
22
10
6
231 ft2
0
0.75
0
8/61201211:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7
N
Cl
N
Ch
m
_
CD
c —
(o
c
D
0)
10 CD
O
O
N
a
0
_
A
0
N
A
-a
0
O
�O3
of
7
idZ
W
N
O
00y
m
CNh
A
W
N
s
O
CO
O
V
0
11
A
W
N
•+
O
m
m
m
m
m
m
m
r
mmmmmZ
m
mm
m
zZ
3
N
W
A
W
O
N
W
N
W
N
V
N
01
N
N
N
>
W
-�
W
N
O
—
W
-�
(0
-�
W
s
Ch
s
0
-a
W
-a
W
-'
-►
-�
s
O
W
V
V
O
cn
W
N
CC
C
��
Z
Ow
O7
N
-
-
-
N
N
-
SI
N
01
-
-
-
C7
CI
Ow
d
N
N
Ow
Ow
p1
-
N
N
Ow
N
61
m
0
0
0
0
0
0
0
O
O
O
O
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
O
0
c
0
c
0
c
0
c
0
c
0
0
0
0
0
c
0
c
0
0
0
0
0
c
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
a
a
a
a
a
c
a
c
a
c
a
c
a
a
a
c
a
c
a
c
a
c
a
a
c
a
c
a
c
a
c
a
c
c
c
a
c
a
c
a
c
a
c
a
c
a
c
a
c
a
c
a
c
a
c
a
c
a
o
0
CD
N
CD
N
CD
N
N
N
.+
(�D
N
N
N
N
N
N
a
a
a
(D
CD
CD
CD
CAD
(D
(D
r.
o.
_.
CD
G
�
or—
0
WOW
N
(mA
(ft
N
N
y
0
0
0
0
0
0
0
0
0
0
y
W
(mA
(
N
!/mw
(4
0
y
N
(mp
N
N
0
C
=
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
y
Ch
0
O
0
W
0
N
a
0
in
CA
Ow
iA
in
N
in
Ch
Ch
Ch
O
CA
O
O
Ch
6
O
6
(Am
O
6
W
O
O
6
O
ih
p
0)
in
CA
O
O
W
Uw
=
0
(A
N
N
(A
N
p1
W
Ch
W
Ch
00
Ch
Ch
O
w
0
01
(i
Ul
�,
v
o
mZ
0
S
=v
O
iw
O
w
O
w
O
is
O
is
O
w
O
w
O
w
O
w
O
w
O
is
O
w
O
w
O
w
O
w
O
w
O
w
O
w
O
w
O
w
O
is
O
w
O
w
O
w
O
is
O
w
O
is
p
w
O
w
O
w
O
w
O
(a
O
w
O
M
CO)
N
0
0
=
O
CD
C2
m
y
O
Ch
A.
W
D
CD
=
cNXE
U
Zn
O
W
O
O
O
OD
V
O
M
CA
O
O
00
Ch
.O
O
=
O
C
-+
-'
''�
-+
-y'
-•
-•
O
O
O
p
O
p
CyDC
p
O
Oy
O
Oyy
O
co
p
O
O
O
o
�
.y.
yO
.Oµ
y
y0y
O
c,O
O
O
O
O
O
O
O
O
O
O
O
O
O
c,O
0
v
7
>
>
7
7
7
=
7
7
7
7
_O
=
7
=
7
7
7
7
7
7
=
7
7
7
=
m
(n 3'
W
.�►
O
O
A
O
O
O
A
O
O
O
O
O
O
O
OO
O
O
O
ON
O
O
CD N
go
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
EF
7
5
7
7
>
>
7
7
=
=
7
3
7
7
7
>
S.
=
7
7
7
7
7
>
>
7
=
7
7
7
C
=
_
v
o
0
0
0
0
0
v
0
o
v
0
0
0
0
o
v
o
0
v
v
0
0
v
0
0
v
0
0
v
v
v
v
O
C�
G-i
0�
0�
0�
A-i
G�
4p�
C-pi
0�
Gp�
0p�
0�
0�
6p�
•Cp�
4�
O�
0�
11�
flw
0p�
p�
4�
0�
Cw
C�
C�
C�
N
C�
0�
7
'•n =
CD
CD
CaD
cD
m
m
fD
cD
tU
cD
cD
CD
(n
m
(p
CD
m
m
y
•0p�
fD
CP
m
m
CA
0
y
m
m
y
m
CG
m
a
C
a
a
a
a
a
asaaa
a
a
a
a
a
a
a
a
aasCaaa
O.
CL
m
=
y
y
y
Vw
0
a
!A
CL
y
y
CA
y
y
(A
CA
y
Caa
y
0
y
W
y
y
(A
to
0
y
0
y
(A
(A
(A
(A
(A
y
y
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
z
Z
Z
O
7
O
=
O
_
O
_
O
=
O
7
O
=
O
7
O
=
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
_
O
=
O
7
O
=
O
=
O
_
O
=
O
_
O
_
O
=
O
_
O
=
O
7
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
=
(Q
GARAGE
#
Floor Area Ceiling Are
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
484 ft2
100 ft2
64 ft 10.5 ft 3
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Best Guess
i
0.000300
I
4013.2 220.32 414.34 0.2696 4.4965
HEATING SYSTEM
#
System Type
Sub pe
Efficiency Capacity Block Block
Ducts
1
2
3
Electric Heat Pump
Electric Heat Pump
Electric Heat Pump
NoneII
None
Non i
`
HSPF: 8.2 41 kBtu/hr 1
HSPF: 8.5 49 kBtu/hr 2
HSPF: 8.5 49.1 kBtu/hr 3
sys#1
sys#2
sys#3
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
3
Central Unit
Central Unit
Central Unit
Non
Non
No7
SEER: 19 35.8 kBtu/hr 1074 cfm 0.75 1
SEER: 18 46.4 kBtu/hr 1392 cfm 0.75 2
SEER: 18 47 kBtulhr 1410 cfm 0.75 3
sys#1
sys#2
sys#3
II
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.96 85 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
I
ft2
DUCTS
V #
— Supply —
Location R-Value Area
— Return — Air Percent
Location Area Leakage Type Handler CFM 25 Leakage ON RLF
HVAC #
Heat Cool
1
2
3
Main 6 146 ft2
1st Floor 6 121 ft2
Attic 6 294 W
Main
1st Floor
Attic
24 ft2 Default Leakage Main (Default) (Default) %
5 ft2 Default Leakage 1st Floor (Default) (Default) %
15 ft' Default Leakage 2nd Floor (Default) (Default) %
1 1
2 2
3 3
8/6/2012 11:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Feb
Feb
Mar
kiMar
A r
Apr
Ma
May
Jun
Jun
Jul
Jul
Au
Aug
Se
Sep
Oct
Oct
Nov
Dec
Dec
Venting Jan
X NovV
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
8/6/2012 11:15 AM Energy auge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7
FORM 405-10
ADDRESS:
Florida Code Compliance Checklist
Florida Departure t of Business and Professional Regulations
Residentiall Whole Building Performance Method
PERMIT #:
Hutchinson Island, FI,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
E Windows
Recessed lighting IC -rated as meeting ASTM 283. and
doors I= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
/
gasketed doors & outdoor combustion air. Must complete envelope
li
leakage report or visually verify Table 402.4.2.
1
Thermostat &
403.1
At leg Ist one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet�the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
pnmery air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing be ducts.
cavities shall not used as supply
Water heaters
403.4
Heai trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
r
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed. to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
/
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Po.I pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
otter means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal 4/16/13). Heat heaters
efficiency=78% (82% after pump pool
miplmum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
/
equipment
occasion cooling or heating capacity requires separate system or
t/
variable capacity system. Electric heat >10kW must be divided into two
or1 more stages.
Ceilings/knee walls
405.2.1
�-19 space permitting.
8/6/2012 11:15 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
I
Page 7 of 7
• 3 � a
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 69
The lower the Ene�gyPerformance Index, the more efficient the home.
Hutchinson Island, Fl,
1. New construction or existing
New (Fr,
m Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-
mily a. Concrete Block - Int Insul, Exterior R=4.1
6188.40 ft2
b. Frame - Steel, Exterior R=11.0
273.00 ft2
3. Number of units, if multiple family
1
c. Concrete Block - Int Insul, Exterior R=13.0
231.00 ft2
4. Number of Bedrooms
4
d. N/A R=
ft2
10. Ceiling Types Insulation
Area
5. Is this a worst case?
No
a. Cathedral/Single Assembly (Unvented) R=30.0
2599.00 ft2
6. Conditioned floor area (ft2)
5100
b. N/A R=
ft2
7. Windows*" Description
Area c. N/A R=
ft2
a. U-Factor. Dbl, U=0.65
1
73.00 fe 11. Ducts
a. Sup: Main, Ret: Main, AH: Main
R ft2
6 146
SHGC: SHGC=0.30
b.'Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor
6 121
b. U-Factor: NIA
ft2 c. Sup: Attic, Ret: Attic, AH: 2nd Floor
6 294
SHGC:
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: NIA
ft2 a. Central Unit 35.8 SEER:19.00
SHGC:
b. Central Unit 46.4 SEER:18.00
d. U-Factor: NIA
ft2 c. Central Unit 47.0 SEER:18.00
13. Heating systems kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump 41.0
HSPF:8.20
Area Weighted Average Overhang Depth:
5.198 ft. b. Electric Heat Pump 49.0
HSPF:8.50
Area Weighted Average SHGC:
0.300 c. Electric Heat Pump 49.1
HSPF:8.50
8. Floor Types Insulation
Area 14. Hot water systems
Cap:
85 gallons
a. Raised Floor R=19.0 3027.00
ft2 a. Electric
EF: 0.96
b. Raised Floor R=0.0 2073.00
ftz
c. NIA R=
f� b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: <2/
Address of New Home:
/�z/z- /3
Date. _
City/FL Zip:
-txE srgT�o.�
fill
xivi a
w tr
�oD WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"'Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
USA - FlaRes2010 Section 405.4.1 Compliant Software