HomeMy WebLinkAboutNOA PLANTATION ROOF TILESMu L..
BUILDING CODE COMPLIANCE OFFICE
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPT
Entegra Roof Tile, Inc.
1289 NE 9" Ave
Okeechobee, FL, 34972
MIAMI-BADE COUNTY, FLORIDA
MCTRO-BADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
INVOS (305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been revie%6d by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade Countyand other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA sliall not be valid after the expi
Division (In Miami Dade County) and/or Ili
have this product or material tested for qual
the accepted manner, the manufacturer wil
revoke, modify, or suspend the use of such p
to revoke this acceptance, if it is determined
material fails to meet the rcquiremenis of the
This product is approved as described
Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
-ation date stated below. The Miami -Dade County Product Control
AHJ (in areas other than Miami Dade County) reserve the right to
ty assurance purposes. If this product or material fails to perform in
incur the expense of such testing and the AHJ may immediately
-oduct or material within their jurisdiction. BORA reserves the right
)y Miami -Dade County Product Control Division that this product or
applicable building code.
and has been designed to comply with the High Velocity Hurricane
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein
RENEWAL of this NOA shall be consider
change in the applicable building code negz
TERMINATION of this NOA will occur ;
materials, use, and/or manufacture of the pt
product, for sales, advertising or any other I
with any section of this NOA shall be cause
ADVERTISEME, NT: The NOA number,
the expiration (late may be displayed in adv
be, done in its entirety.
INSPECTION: A copy of this entire NOA
and shall be available for inspection at the j
This revises NOA No. 10-0804.15 and
The submitted documentation was revi
0 after a renewal application has been filed and there has been no
ively affecting the performance of this product.
fter the expiration date or if there has been a revision or change in the
iduct or process. Misuse of this NOA as an endorsement of any
urposes shall automatically terminate this NOA. Failure to comply
for termination and removal of NOA.
receded by the words Miami -Dade County, Florida, and followed by
rtising literature. If any portion of the NOA is displayed, then it shall
shall be provided to the user by the manufacturer or its distributors
ib site at the request of the Building Official.
sts of pages I through 5.
by Alex Tigera.
NOA No.: 10-1202.01
Expiration Date:12/08/15
Approval Date: 12/30/10
. Page 1 of 5
�G
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE:
This renews a roofing system using
for Entegra Roof Tile, Inc. in Oke
Acceptance. For the locations wher
Building Code, does not exceed
calculations shall be done as a mome:
2. PRODUCT DESCRIPTION:
Manufactured by
Applicant
Plantation Tile
Trim Pieces
Dimensions
Length: 16'/z"
Width: 13"
Length: varies
Width: varies
Thickness: varies
3. LIMITATIONS:
3.1
Fire classification is not pi
3.2
For mortar or adhesive set
TAS 106 may required, re
3.3
Applicant shall retain the:
perform quarterly test in a.
submitted to the Building 1
3.4
Minimum underlayment sl
Applications Standards lis
3.5
30/90 hot mopped underla
slope unless stated otherw
literature.
3.6
This acceptance is for wo(
compliance with applicabl
?ntegra "Plantation" concrete roof tile, as manufactured
chobee, FL as described in Section 2 of this Notice of
the pressure requirements, as determined by applicable
Ie values listed in section 4 herein. The attachment
t based system.
Test Product
ecifications Description
Flat concrete roof tile for direct deck or
TAS 112 batten nail -on..
Accessory trim, concrete roof pieces for
TAS 112 use at hips, rakes ridges and valley
terminations
of this acceptance,
le applications, a static field uplift test in accordance with
to applicable building code.
vices of a Miami -Dade County Certified Laboratory to
:)rdance with TAS 112, appendix `A'. Such testing shall be
ide Compliance Office for review.
1 be in compliance with the applicable Roofing
i section 4.1 herein.
lent applications may be installed perpendicular to the roof
by the underlayment material manufacturers published
deck applications. Minimum deck requirements shall be in
building code.
4. INSTALLATION:
4.1 Entegra Roof Tile, Inc.'s Plantation Flat Tile and its components shall be installed in
strict compliance with Roofing Application Standard RAS 118,119, & 120
4.2 Data For Attachment Calculations
MIAMI-DADE COUNTY
NOA No.: 10-1202.01
Expiration Date: 12/08/15
Approval Date: 12/30/10
Page 2 of 5
Table 1: Average Wei 19ht (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
I
Length -I (ft)
Width-w (ft)
Plantation Tile
111.6
1.375
1.08
Table 2: Aerod namic Multi liens - 7. ft3
Tile
Profile
I % (ft3)
Batten Application
1 (ft3)
Direct Deck Application
Plantation Tile
1 0.267
0.289
Table 3: Restoring
Moments due to Gravity - M {ft-Ibf)
Tile
211: 12"
3": 12"
411: 12"
1
511
: 12"
620
: 12"
Greater than
Profile
7": 12"
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
Deck
Deck
Plantation
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Tile
Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf)
For Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(Min 15132"
plywood)
Direct Deck
(Min. 19132"
plywood)
Battens
Plantation Tile
2-10d Ring Shank Nails
30.9
38.1
17.2
1-10d Smooth or Screw
Shank Nail 1
7.3
9.8
4.9
2-10d Smooth or S I'rew
Shank Nails
14.0
18.8
7.4
1 #8 Screw 1
30.8
30.8
18.2
2 #8 Screw I
51.7
51.7
24.4
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field blip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
I
2-10d Ring Shi'nk
Nails'
50.3
85.5
48.3
1 Installation with a 4" the headlap and fasteners are located a minimum of 2'/2" from the head of tile.
NOA No.: 10-1202.01
MLAM bDADECOUNTY Expiration Date: 12/08/15
Approval Date: 12/30/10
Page 3 of 5
Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
For Two Patty' Adhesive Set Systems
TileMinimum
Profile
Tile Application
Attachment
Resistance
Plantation Tile I
Adhesive
31.3
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TlleBond Average.weights per patty 13.9 grams.
Pol oam Product, Inc. Average wei ht per att 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
For Single Patty Adhesive Set System
Tile Profile
I Tile Application
Minimum Attachment
Resistance
Plantation Tile
Pol ProTm
118.9
I Pol ProTA°
40.4
4 Large paddy placement of 45 grams of Pol Pro TM.
5 Medium paddy placement of 24 grams of Pol ProTm.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile Profile I Tile Application Attachment
Resistance
Seespecific mortar (manufacturer's Notice of Acceptance.
5. LABELING
5.1 All tiles shall bear ,the imprint or identifiable marking of the manufacturer's name or logo
as seen below or following �tatement: "Miami -Dade County Product Control Approved".
5.2 Entegra Roof Tile, Inc.'s Plantation Roof Tile bears the following markings: USA "E"
USA, "E", Entegra "E", where the E is a stylized logo.
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documepts required by the Building Official or applicable Building
Cod6 in order to properly evaluate the installation of this system.
7. MANuFACTURING LOCA
7.1 Okeechobee, FL
I
I
I
NOA No.: 10-1202.01
MIAMI•DA13E CdUNTv Expiration Date: 12/08/15
I Approval Date: 12/30/10
Page 4 of 5
1202.01
Expiration Date:12/08/15
Approval Date: 12/30/10
Page 5 of 5