HomeMy WebLinkAboutNOA PLANTATION ROOF TILESMu L.. BUILDING CODE COMPLIANCE OFFICE PRODUCT CONTROL DIVISION NOTICE OF ACCEPT Entegra Roof Tile, Inc. 1289 NE 9" Ave Okeechobee, FL, 34972 MIAMI-BADE COUNTY, FLORIDA MCTRO-BADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 INVOS (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been revie%6d by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade Countyand other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA sliall not be valid after the expi Division (In Miami Dade County) and/or Ili have this product or material tested for qual the accepted manner, the manufacturer wil revoke, modify, or suspend the use of such p to revoke this acceptance, if it is determined material fails to meet the rcquiremenis of the This product is approved as described Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile -ation date stated below. The Miami -Dade County Product Control AHJ (in areas other than Miami Dade County) reserve the right to ty assurance purposes. If this product or material fails to perform in incur the expense of such testing and the AHJ may immediately -oduct or material within their jurisdiction. BORA reserves the right )y Miami -Dade County Product Control Division that this product or applicable building code. and has been designed to comply with the High Velocity Hurricane LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein RENEWAL of this NOA shall be consider change in the applicable building code negz TERMINATION of this NOA will occur ; materials, use, and/or manufacture of the pt product, for sales, advertising or any other I with any section of this NOA shall be cause ADVERTISEME, NT: The NOA number, the expiration (late may be displayed in adv be, done in its entirety. INSPECTION: A copy of this entire NOA and shall be available for inspection at the j This revises NOA No. 10-0804.15 and The submitted documentation was revi 0 after a renewal application has been filed and there has been no ively affecting the performance of this product. fter the expiration date or if there has been a revision or change in the iduct or process. Misuse of this NOA as an endorsement of any urposes shall automatically terminate this NOA. Failure to comply for termination and removal of NOA. receded by the words Miami -Dade County, Florida, and followed by rtising literature. If any portion of the NOA is displayed, then it shall shall be provided to the user by the manufacturer or its distributors ib site at the request of the Building Official. sts of pages I through 5. by Alex Tigera. NOA No.: 10-1202.01 Expiration Date:12/08/15 Approval Date: 12/30/10 . Page 1 of 5 �G ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This renews a roofing system using for Entegra Roof Tile, Inc. in Oke Acceptance. For the locations wher Building Code, does not exceed calculations shall be done as a mome: 2. PRODUCT DESCRIPTION: Manufactured by Applicant Plantation Tile Trim Pieces Dimensions Length: 16'/z" Width: 13" Length: varies Width: varies Thickness: varies 3. LIMITATIONS: 3.1 Fire classification is not pi 3.2 For mortar or adhesive set TAS 106 may required, re 3.3 Applicant shall retain the: perform quarterly test in a. submitted to the Building 1 3.4 Minimum underlayment sl Applications Standards lis 3.5 30/90 hot mopped underla slope unless stated otherw literature. 3.6 This acceptance is for wo( compliance with applicabl ?ntegra "Plantation" concrete roof tile, as manufactured chobee, FL as described in Section 2 of this Notice of the pressure requirements, as determined by applicable Ie values listed in section 4 herein. The attachment t based system. Test Product ecifications Description Flat concrete roof tile for direct deck or TAS 112 batten nail -on.. Accessory trim, concrete roof pieces for TAS 112 use at hips, rakes ridges and valley terminations of this acceptance, le applications, a static field uplift test in accordance with to applicable building code. vices of a Miami -Dade County Certified Laboratory to :)rdance with TAS 112, appendix `A'. Such testing shall be ide Compliance Office for review. 1 be in compliance with the applicable Roofing i section 4.1 herein. lent applications may be installed perpendicular to the roof by the underlayment material manufacturers published deck applications. Minimum deck requirements shall be in building code. 4. INSTALLATION: 4.1 Entegra Roof Tile, Inc.'s Plantation Flat Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,119, & 120 4.2 Data For Attachment Calculations MIAMI-DADE COUNTY NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 2 of 5 Table 1: Average Wei 19ht (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) I Length -I (ft) Width-w (ft) Plantation Tile 111.6 1.375 1.08 Table 2: Aerod namic Multi liens - 7. ft3 Tile Profile I % (ft3) Batten Application 1 (ft3) Direct Deck Application Plantation Tile 1 0.267 0.289 Table 3: Restoring Moments due to Gravity - M {ft-Ibf) Tile 211: 12" 3": 12" 411: 12" 1 511 : 12" 620 : 12" Greater than Profile 7": 12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) For Nail -On Systems Tile Profile Fastener Type Direct Deck (Min 15132" plywood) Direct Deck (Min. 19132" plywood) Battens Plantation Tile 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 1 7.3 9.8 4.9 2-10d Smooth or S I'rew Shank Nails 14.0 18.8 7.4 1 #8 Screw 1 30.8 30.8 18.2 2 #8 Screw I 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field blip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 I 2-10d Ring Shi'nk Nails' 50.3 85.5 48.3 1 Installation with a 4" the headlap and fasteners are located a minimum of 2'/2" from the head of tile. NOA No.: 10-1202.01 MLAM bDADECOUNTY Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 3 of 5 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) For Two Patty' Adhesive Set Systems TileMinimum Profile Tile Application Attachment Resistance Plantation Tile I Adhesive 31.3 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TlleBond Average.weights per patty 13.9 grams. Pol oam Product, Inc. Average wei ht per att 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Single Patty Adhesive Set System Tile Profile I Tile Application Minimum Attachment Resistance Plantation Tile Pol ProTm 118.9 I Pol ProTA° 40.4 4 Large paddy placement of 45 grams of Pol Pro TM. 5 Medium paddy placement of 24 grams of Pol ProTm. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile I Tile Application Attachment Resistance Seespecific mortar (manufacturer's Notice of Acceptance. 5. LABELING 5.1 All tiles shall bear ,the imprint or identifiable marking of the manufacturer's name or logo as seen below or following �tatement: "Miami -Dade County Product Control Approved". 5.2 Entegra Roof Tile, Inc.'s Plantation Roof Tile bears the following markings: USA "E" USA, "E", Entegra "E", where the E is a stylized logo. 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documepts required by the Building Official or applicable Building Cod6 in order to properly evaluate the installation of this system. 7. MANuFACTURING LOCA 7.1 Okeechobee, FL I I I NOA No.: 10-1202.01 MIAMI•DA13E CdUNTv Expiration Date: 12/08/15 I Approval Date: 12/30/10 Page 4 of 5 1202.01 Expiration Date:12/08/15 Approval Date: 12/30/10 Page 5 of 5