RESIDENTIAL HVAC LOADS
' Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor , A Private Residence Fort Lauderdale, FL 33308 Page 2 Project Report General Project fnformation a- Project Title: A Private Residen e Designed By: R.W. Taylor Project Date: Wednesday, July 18, 2012 Client Name: A Private Residen e Client Address: Huchenson Island Client City: St. Lucie, Florida Company Name: The Benedicy Grow Company Representative: R.W. Taylor Company Address: 1525 N.W.3rd St 1 Company City: Deerfield Beach, lorida Company Phone: 954-57--9500 Design'Data Reference City: Port St. Lucie, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Differene Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61 Check Figures Total Building Supply CFM: 4,600 CFM Per Square ft.: 0.902 Square ft. of Room Area: 5,100 Square ft. Per Ton: 492 Volume (ft3) of Cond. Space: 3,455 Building Loads Total Heating Required Including Ventilation Air: 113,524 Btuh 113.524 MBH Total Sensible Gain: 98,970 Btuh 80 % Total Latent Gain: 25,418 Btuh 20 % I Total Cooling Required Including Ventilation Air: 124,387 Btuh 10.37 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:1... 1Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac sResidential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 3 Miscellaneous Report System 1 Zone #1 1st Floor/Vestibule y Outdoor Outdoor ' Grains Outdoor �i 'Indoor Indoor Input Data Dry Bulb Bulb Rel.Hum, ReLHum Dry Bulb Differene Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 System 2 Zone#2, 1st FI' S.E. Outdoor Outdoor" Outdoor Indoor Indoor) Grains Input Data Dry Bulb Wet Bulb Rel.Hum.. Rel.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 System 3 2Nd Fioor Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb _ Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.610 AC/hr 0.464 AC/hr 544 413 CFM �FM Infiltration Actual: 0.610 C/hr 0.464 AC/hr Above Grade Volume: X 53,455 u.ft. X 53,455 Cu.ft. 32,622 u.ft./hr 24,786 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 544 FM 413 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.590 AC/hr (134 CFM) Summer Infiltration Specified: 0.520 AC/hr (118 CFM) -System 2-- Infiltration & Ventilation Sensible Gain Multipliler: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplierf 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.650 AC/hr (196 CFM) Summer Infiltration Specified: 0.510 AC/hr (154 CFM) --System 3- Infiltration & Ventilation Sensible Gain Multip ier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) C:1... 1Aprivate Res' 7-18-12.rhv i Sunday, August 05, 2012, 2:42 PM Rhvac AResidential & Light Commercial HVAC Loads Richard Taylor Fort Lauderdale, FL 33308 jo Elite Software Development, Inc. A Private Residence Page 4 Miscellaneous Report (cont'd) Outside Air Data Infiltration & Ventilation Latent Gain Multiplier: Infiltration & Ventilation Sensible Loss Multiplier: Winter Infiltration Specified: 0.590 AC/hr (21 Summer Infiltration Specified: 0.390 AC/hr (14 41.50 = 30.77 = CFM) CFM) (0.68 X 0.999 X 61.09 Grains Difference) (1.10 X 0.999 X 28.00 Winter Temp. Difference) Duct Load Factor Scenarios for System 1 No. Type Description Location Attic Ceiling Duct Leakage Duct Insulation Surface Area From MDD 1 Supply Main Attic 1 Return Main Attic 16B 16B 0.12 0.24 6 6 865 320 No No Duct Load Factor Scenarios for System 2 No. Type Description Location Attic Ceiling Duct Leakage Duct Insulation Surface Area From MDD 1 Supply Main Attic 16B 0.12 6 442 No Duct Load Factor Scenarios for System 3 No. Type Description Location Attic Ceiling Duct eaka e' Leakage' Duct Insulation Surface Area From MDD 1 Supply Main Attic 1 Return Main Attic 16B 16B 0.12 0.24 6 6 560 104 No No C:\ ...1Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -',Residential & Light Commercial HVAC Loads 04, Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 5 Total Building Summary Loads Component Area Sens Lat Description Quan . L`osss Y Gain :Gain Total Gain New Material: Glazing -Hi Impact Tinted Glass, u-v lue 1241 22,586 0 35,139 35,139 0.65, SHGC 0.3 New Material: Glazing -Hi Impact Tinted Glass, u- lue 32 627 0 2,028 2,028 0.7, SHGC 0.55 New Material: Glazing -Hi Impact Tinted Glass, u- alue 100 1,820 0 1,607 1,607 0.65, SHGC 0.3 Concrete Block: Wall -Frame, Custom, Concrete lock w/ 4942.9 33,770 0 20,990 20,990 R-4.1 Insulation 1213-0sm: Part -Frame, R-11 insulation in 2 x 4 st d cavity, 260 582 0 291 291 no board insulation, siding finish, metal studs Custom Roof: Roof/Ceiling-Under Attic with Insul tion on 2599 2,329 0 3,327 3,327 Attic Floor (also use for Knee Walls and Parti ion Ceilings), Custom, Concrete ROOf w/ E-30 In ulation 22A-pl-c: Floor -Slab on grade, No edge insulation, no 79 2,188 0 0 0 insulation below floor, carpet covering, passiL, light dry soil Over Gagage Area: Floor -Over enclosed unconditioned 1046 310 0 166 166 crawl space, Custom, Enclosed floor over Garage R- 19 Over Enclosed space: Floor -Over enclosed 1639 2,352 0 1,260 1,260 unconditioned crawl space, Custom, Over enclosed space R-30 Subtotals for structure: 66,564 0 64,808 64,808 People: 5 1,000 1,150 2,150 Equipment: 1,000 2,400 3,400 Lighting: 0 0 0 Ductwork: 30,230 6,273 23,803 30,075 Infiltration: Winter CFM: 544, Summer CFM: 4 3 16,730 17,145 6,809 23,954 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 113,524 25,418 98,970 124,387 Check Figures ;. Total Building Supply CFM: 4,600 CFM Per Square ft.: 0.902 Square ft. of Room Area: 5,100 Square ft. Per Ton: 492 Volume (fP) of Cond. Space: 53,455 Building Loads - Total Heating Required Including Ventilation Air: 113,524 Btuh 113.524 MBH Total Sensible Gain: I 98,970 Btuh 80 % Total Latent Gain: 25,418 Btuh 20 % Total Cooling Required Including Ventilation Air- 124,387 Btuh 10.37 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and N anual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM ' Rhvac 'Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 6 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Components r Areas -Sen �Lat �� °�Sen'� �. Total �..: s x z s 16i a _ r; Doss `,. ` . , Qom' Description r. .. , uany. •.Gain ..::Gam . G ain New Material: Glazing -Hi Impact Tinted Glass, u- alue 202.5 3,685 0 4,919 4,919 0.65, SHGC 0.3 Concrete Block: Wall -Frame, Custom, Concrete block w/ 1396.3 9,541 0 5,929 5,929 R-4.1 Insulation 12B-Osm: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 260 582 0 291 291 no board insulation, siding finish, metal studs 22A-pl-c: Floor -Slab on grade, No edge insulatio , no 79 2,188 0 0 0 insulation below floor, carpet covering, passiv , light dry soil Over Gagage Area: Floor -Over enclosed uncondi ioned 1046 310 0 166 166 crawl space, Custom, Enclosed floor over Ga age R- 19 Subtotals for structure: 16,306 0 11,305 11,305 People: 0 0 0 0 Equipment: 1,000 2,400 3,400 Lighting: 0 0 0 Ductwork: 13,986 0 12,690 12,690 Infiltration: Winter CFM: 134, Summer CFM: 11 4,123 4,901 1,946 6,847 System 1, Zone 1 Load Totals: 34,415 5,901 28,341 34,242 Check Figures Supply CFM: 1,300 CFM Per Square ft.: 0.995 Square ft. of Room Area: 11,307 Square ft. Per Ton: 458 Volume (fP) of Cond. Space: 13,625 Zone. Loads �, > Total Heating Required: 34,415 Btuh 34.415 MBH Total Sensible Gain: 28,341 Btuh 83 % Total Latent Gain: 5,901 Btuh 17 % Total Cooling Required: 34,242 Btuh 2.85 Tons (Based On Sensible + Latent) Notes4. Rhvac is an ACCA approved Manual J and Ma ual D computer program. Calculations are performed per ACCA Manual 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building U Use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -'Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor + A Private Residence Fort Lauderdale, FL 33308 Page 7 System Z Zone 2 Summary Loads (Aerage Load Procedure for Rooms) Component s } nArea;S.en Lat ` Sen aT:otal ` Description Quan'Lossx yGain Gamy. Gain New Material: Glazing -Hi Impact Tinted Glass, u-V lue 534.5 9,728 0 0.65, SHGC 0.3 15,771 15,771 New Material: Glazing -Hi Impact Tinted Glass, u- alue 32 627 0 2,028 2,028 0.7, SHGC 0.55 Concrete Block: Wall -Frame, Custom, Concrete lock w/ 1426.2 9,744 0 6,058 6,058 R-4.1 Insulation Custom Roof: Roof/Ceiling-Under Attic with Insul tion on 526 471 0 673 673 Attic Floor (also use for Knee Walls and Parti ion Ceilings), Custom, Concrete ROOf w/ E-30 In ulation Over Enclosed space: Floor -Over enclosed 1639 2,352 0 1,260 1,260 unconditioned crawl space, Custom, Over en losed space R-30 Subtotals for structure: 22,922 0 25,790 25,790 People: 2 400 460 860 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 7,041 0 4,237 4,237 Infiltration: Winter CFM: 196, Summer CFM: 154 6,020 6,372 2,531 8,903 System 2, Zone 2 Load Totals: 35,983 6,772 33,018 39,790 Check Figures Supply CFM: 1,600 CFM Per Square ft.: 0.930 Square ft. of Room Area: 1,720 Square ft. Per Ton: 519 Volume (ft) of Cond. Space: 18,062 Zone Loads Total Heating Required: 35,983 Btuh 35.983 MBH Total Sensible Gain: 33,018 Btuh 83 % Total Latent Gain: 6,772 Btuh 17 % Total Cooling Required: 39,790 Btuh 3.32 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manuai D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I C:1...Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -•Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor it A Private Residence io Fort Lauderdale, FL 33308 Page 8 System 3, Zone 3 Summary Loads -(A erage Load Procedure for Rooms) Com onent: Affix" Sen resat ` >'SenY P g5`= Y - ..:r Des criptiori� �' Quan� Loss° ?Galn., Gain, Galn New Material: Glazing -Hi Impact Tinted Glass, u- alue 504 9,173 0 14,449 14,449 0.65, SHGC 0.3 New Material: Glazing -Hi Impact Tinted Glass, u- alue 100 1,820 0 1,607 1,607 0.65, SHGC 0.3 Concrete Block: Wall -Frame, Custom, Concrete lock w/ 2120.3 14,485 0 9,003 9,003 R-4.1 Insulation Custom Roof: Roof/Ceiling-Under Attic with Insul tion on 2073 1,858 0 2,654 2,654 Attic Floor (also use for Knee Walls and Parti ion Ceilings), Custom, Concrete ROOf w/ E-30 In ulation Subtotals for structure: 27,336 0 27,713 27,713 People: 3 600 690 1,290 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 9,204 0 6,876 6,876 Infiltration: Winter CFM: 214, Summer CFM: 14 6,587 5,872 2,332 8,204 System 3, Zone 3 Load Totals: 43,127 6,472 37,611 44,083 Check Figures Supply CFM: 1,700 CFM Per Square ft.: 0.820 Square ft. of Room Area: 2,073 Square ft. Per Ton: 564 Volume (ft) of Cond. Space: 21,768 Zone Loads Total Heating Required: 43,127 Btuh 43.127 MBH Total Sensible Gain: 37,611 Btuh 85 % Total Latent Gain: 6,472 Btuh 15 % Total Cooling Required: 44,083 Btuh 3.67 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and M nual D computer program. Calculations are performed per ACCA Manual JJ 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...1Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM ' Rhvac -*Residential & Light Commercial HVAC Loads Elite SoHware Development, Inc. Richard Taylor _ A Private Residence Fort Lauderdale, FL 33308 Page 9 Detailed Room Loads - Room 1 - Vestibule /Stairs (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 202.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 202.0 sq.ft. Supply Air: 313 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 9.3 AC/hr Volume: 2,020.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 104 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 532 ft./m n. Percent of Supply: 0 % Runout Air Velocity: 532 ft./min. Actual Winter Infil.: 44 CFM Actual Loss: 0.181 in.wj./100 ft. Actual Summer Infil.: 39 CFM Item Deserlptlon, - : Qualittj Value aHTM=��Loss� HTM�GLa Gain E -Wall-Concrete Block 11.5 X 10 115 0.244 6.8 786 4.2 0 488 S -Wall-Concrete Block 15.3 X 10 153 0.244 6.8 1,045 4.2 0 650 W -Wall-Concrete Block 11.5 X 115 0.244 6.8 786 4.2 0 488 10 SW -Wall -Concrete Block 7.5 X 52.5 0.244 6.8 359 4.2 0 223 10 NW -Wall -Concrete Block 7.3 X 61 0.244 6.8 417 4.2 0 259 10 N -Part-100/200-12B-Osm 26 X 10 260 0.112 2.2 582 1.1 0 291 SW -GIs -New Material shgc-0.3 22.5 0.650 18.2 409 16.1 0 362 100%S NW -GIs -New Material shgc-0.3 12 0.650 18.2 218 30.5 0 366 0%S Floor-22A-pl 79 ft..Per. 79 0.989 27.7 2,188 0.0 0 0 Subtotals for Structure: 6,790 0 3,127 Infil.: Win.: 44.5, Sum.: 39.2 531 2.578 1,369 1.217 1,628 646 Ductwork: 5,586 3,059 Room Totals: 13,745 1,628 6,832 C:\ ...Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM I Rhvac -Aesidential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 10 Detailed Room Loads - Room 4 - "cen (Average Load Procedure) M-1 �* I T; Wr Aw Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 335.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 335.0 sq.ft. Supply Air: 261 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 4.4 AC/hr Volume: 3,518.0 cuft Req. Vent. Cig: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 130 CF Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: Im 488 Urn I n . Percent of Supply: 0 % Runout Air Velocity: I 488 ft./ in. I Actual Winter Infil.: 11 CFM Actual Loss: 0.124 in.w .1100 ft. Actual Summer Infil.: 9 CFM Arena= S_A C eq T,Loss HN 07A, W -Wall-Concrete Block 12 X 126 0.244 6.8 861 4.2 0 535 10.5 Floor -Over GagageArea 1 X 335 335 0.053 0.3 99 0.2 0 53 Subtotals for Structure: 960 0 588 Infil.: Win.: 10.6, Sum.: 9.3 126 2.579 325 1.214 386 153 Ductwork: 880 2,547 Equipment: 1,000 2,400 Room Totals: 2,165 1,386 5,688 C:\ ... \Aprivate Res'7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -*Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Pa a 11 Detailed Room Loads - Room 5 - Bre kfast Area (Average Load Procedure) Genes"al: r r. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 385.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 385.0 sq.ft. Supply Air: 403 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 6.0 AC/hr Volume: 4,043.0 cu.ft Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 0 CFM Runout Air: 101 CF Percent of Supply.: 0 % Runout Duct Size: 6 in. I Actual Summer Vent.: 0 CFM Runout Air Velocity: 513 ft./ in. Percent of Supply: 0 % Runout Air Velocity: 513 ft./ in. Actual Winter Infil.: 32 CFM Actual Loss: 0.168 in. g./l00 ft. Actual Summer Infil.: 28 CFM Item ; f Area: 3 U r{� Fzit9gSenx.�r 9�n Description �`' ..., ., ` . "Q`uanti ' value :HTMt >Loss HTMrrr, r�"Galn,' Gain N -Wall-Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 NE -Wall -Concrete Block 15.9 X 136.9 0.244 6.8 936 4.2 0 581 10.5 E -Wall-Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 SE -Wall -Concrete Block 10 X 57 0.244 6.8 389 4.2 0 242 10.5 N -GIs-New Material shgc-0.3 15 0.650 18.2 273 16.1 0 241 100%S NE -GIs -New Material shgc-0.3 30 0.650 18.2 546 30.5 0 915 0%S E -GIs-New Material shgc-0.3 15 0.650 18.2 273 38.6 0 579 0%S SE -GIs -New Material shgc-0.3 48 0.650 18.2 874 30.3 0 1,452 0%S Floor -Over Gagage Area 1 X 385 385 0.053 0.3 114 0.2 0 61 Subtotals for Structure: 1 3,917 0 4,389 Infil.: Win.: 31.6, Sum.: 27.8 377 2.579 972 1.218 1,155 459 Ductwork: 3,347 3,931 Room Totals: 8,236 1,155 8,779 C:1... 1Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac dResidential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor + A Private Residence Fort Lauderdale, FL 33308 Page 12 Detailed Room Loads - Room 6 - Pan ry (Average Load Procedure) Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 32.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 32.0 sq.ft Supply Air: 0 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 0.0 AC/hr Volume: 336.0 cu.ft Req. Vent. Clg: 0 CFM Number of Registers: 0 Actual Winter Vent.: 0 CFM Runout Air: 0 CF Percent of Supply.: 0 % Runout Duct Size: 0 in. I Actual Summer Vent.: 0 CFM Runout Air Velocity: 0 ft./rrIln. Percent of Supply: 0 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in. g./100 ft. Actual Summer Infil.: 0 CFM Item' Area HI Sen Clg Lat Seri DesP tionti. P< _.,., ,, Qwanti `� ; value HTM Less .. HTM Gain Gain Subtotals for Structure: 0 0 0 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Room Totals: 0 0 0 C:\ ...1Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac *Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor 1*0 A Private Residence Fort Lauderdale, FL 33308 Pa a 13 Detailed Room Loads - Room 7 - Pd' m' (Average Load Procedure) Geieral� , �w t . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 27.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 27.0 sq.ft Supply Air: 0 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 0.0 AC/hr Volume: 284.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 0 Actual Winter Vent.: 0 CFM Runout Air: 0 CF Percent of Supply.: 0 % Runout Duct Size: 0 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 0 ft./ In. Percent of Supply: 0 % Runout Air Velocity: 0 ft./�in. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 In.wg./100 ft. Actual Summer Infil.: 0 CFM Iterny '' Areas U- flWffil. W,Q Sene A HLoss Gain ainF Subtotals for Structure: 0 0 0 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Room Totals: 0 0 0 C:\ ...Wprivate Res' 7-18-12.rhv II Sunday, August 05, 2012, 2:42 PM ' Rhvac ?Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 14 Detailed Room Loads - Room 8 - Lau dry (Average Load Procedure) . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 67.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 67.0 sq. Supply Air: 85 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 7.2 AC/hr Volume: 704.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 85 CF Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 621 ft./Tin. Percent of Supply: 0 % Runout Air Velocity: 621 ft./min. Actual Winter Infil.: 14 CFM Actual Loss: 0.317 in.v�rg./100 ft. Actual Summer Infil.: 12 CFM Item OttSF f {'n3�"UXI 9 .. Sen . Clg .. Late Sen �rx .. Quan�tlty�Value Desciptlona f �'. HTM Loss FriTM Gale `,� Gala , , S -Wall-Concrete Block 7.5 X 68.8 0.244 6.8 470 1. 4.2 0 292 10.5 W -Wall-Concrete Block 8 X 10.5 84 0.244 6.8 574 4.2 0 357 S -GIs-New Material shgc-0.3 10 0.650 18.2 182 16.1 0 161 95%S Floor -Over Gagage Area 1 X 67 67 0.053 0.3 20 0.2 0 11 Subtotals for Structure: 1,246 0 821 Infil.: Win.: 13.6, Sum.: 12.0 163 2.581 420 1.217 499 198 Ductwork: 1,141 826 Room Totals: 2,807 499 1,845 C:1... Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM 'Rhvac .-,Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 15 Detailed Room Loads - Room 9 - Hall/Elevator (Average Load Procedure) Calculation Mode: Htg. & cIg. Occurrences: 1 Room Length: 259.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 259.0 sq.ft Supply Air: 238 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 5.3 AC/hr Volume: 2,720.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 119 CF Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 607 ft./min. I Percent of Supply: 0 % Runout Air Velocity: i 607 ft./ Actual Winter Infil.: 34 CFM Actual Loss: ;n. 0.235 in g./1 00 ft. Actual Summer Infil.: I 30 CFM 10'! lk�t h Loss T _Oss E -Wall-Concrete Block 11.5 X 120.8 0.244 6.8 825 4.2 0 513 10.5 S -Wall-Concrete Block 15.3 X 110.7 0.244 6.8 756 4.2 0 470 10.5 W -Wall-Concrete Block 11.5 X 120.8 0.244 6.8 825 4.2 0 513 10.5 S -GIs-New Material shgc-0.3 50 0.650 18.2 910 16.9 0 843 O%S Floor -Over Gagage Area 1 X 259 259 0.053 0.3 77 0.2 0 41 Subtotals for Structure: 3,393 0 2,380 Infil.: Win.: 33.7, Sum.: 29.7 4021 2.579 1,037 1.218 1,233 490 Ductwork: 3,033 2,327 Room Totals: 7,463 1,233 5,197 C:\ ... \Aprivate Res'7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM ' Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 16 Detailed Room Loads - Room 2 - Gre t Room (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 526.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 526.0 sq. Supply Air: 690 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 7.5 AC/hr Volume: 5,523.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 6 Actual Winter Vent.: 0 CFM Runout Air: 115 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 586 ft./ in. Percent of Supply: 0 % Runout Air Velocity: 586 ft./ in. Actual Winter Infil.: 58 CFM Actual Loss: 0.219 in. g./100 ft. Actual Summer Infil.: 46 CFM Item .: � : r Area {kU Htgoq �� Send°,� Clg p, aLat ` Sen " L G2uanti, " Description ? Y � nUalue HTNI: -, �.-=LossHTMAa.Gain E -Wall-Concrete Block 25.2 X 12 141 0.244 6.8 963 4.2 0 599 SE -Wall -Concrete Block 12 X 12 96 0.244 6.8 656 4.2 0 408 NE -Wall -Concrete Block 12 X 12 96 0.244 6.8 656 4.2 0 408 E -GIs-New Material shgc-0.3 135 0.650 18.2 2,457 38.6 0 5,211 0%S (3) E -GIs-New Material shgc-0.3 27 0.650 18.2 492 38.6 0 1,041 0%S (3) SE -GIs -New Material shgc-0.3 48 0.650 18.2 874 30.3 0 1,452 0%S NE -GIs -New Material shgc-0.3 48 0.650 18.2 874 30.5 0 1,464 0%S UP-Ceil-Custom Roof 526 X 1 5261 0.032 0.9 471 1.3 0 673 Floor -Over Enclosed space 1 X 526 0.320 1.4 755 0.8 0 404 526 Subtotals for Structure: 8,198 0 11,660 Infil.: Win.: 58.0, Sum.: 45.5 59 3.022 1,786 1.271 1,890 751 Ductwork: 2,429 1,827 Room Totals: 12,413 1,890 14,238 C:\ ...Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 17 Detailed Room Loads - Room 3 - Ves'YCoatsIU(Average Load Procedure) ieheqag-. I ; General Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 81.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 81.0 sq.ft Supply Air: 23 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 1.6 AC/hr Volume: 851.0 cu. Req. Vent. C1g: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air. 23 CF Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 258 Urn, in. Percent of Supply: 0 % Runout Air Velocity: 258 "T in. Actual Winter Infil.: 7 CFM Actual Loss: 0.077 in. g]l 00 ft. Actual Summer Infil.: 6 CFM t HYtI dt F mw _ ' I Deseripfion<W 4 d5ntitV, �R 9 HT" M, M W -Wall-Concrete Block 7 X 10.5 73.5 0.244 6.8 502 4.2 0 312 Subtotals for Structure: 502 0 312 Infil.: Win.: 7.2, Sum.: 5.7 74 3.020 222 1.265 235 93 Ductwork: 176 60 Room Totals: 900 235 465 C:\ ... \Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor � A Private Residence Fort Lauderdale, FL 33308 Page 18 Detailed Room Loads - Room 10 - F er (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 243.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 243.0 sq. Supply Air: 339 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 8.0 AC/hr Volume: 2,552.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 3 I Actual Winter Vent.: 0 CFM Runout Air: 113 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. I Actual Summer Vent.: 0 CFM Runout Air Velocity: 575 ft'/ in. Percent of Supply: 0 % Runout Air Velocity: 575 ft./ in. Actual Winter Infil.: 25 CFM Actual Loss: 0.211 in. g./100 ft. Actual Summer Infil.: 20 CFM item: ,Area<� Dr,Ht9 rtfSe���r}I9;,,,Lat� ' Sen �� Descrlpfion . ''`` Quantity Value , HTM�oss, `.'PiHTRNI ;�r .nGam ,. i`Gain S -Wall-Concrete Block 6 X 10.5 31 0.244 6.8 212 4.2 0 132 SW -Wall -Concrete Block 12.5 X 14.2 0.244 6.8 97 4.2 0 60 10.5 W -Wall-Concrete Block 6 X 10.5 31 0.244 6.8 212 4.2 0 132 S -GIs-New Material shgc-0.3 32 0.650 18.2 582 16.1 0 514 100%S SW -GIs -New Material shgc-0.3 45 0.650 18.2 819 19.2 0 863 78%S SW -GIs -New Material shgc-0.3 32 0.650 18.2 582 19.9 0 636 73%S (2) SW -GIs -New Material shgc-0.3 40 0.650 18.2 728 30.3 0 1,210 0%S W -GIs-New Material shgc-0.55 32, 0.700 19.6 627 63.4 0 2,028 0%S Floor -Over Enclosed space 1 X 243 0.320 1.4 349 0.8 0 187 243 Subtotals for Structure: 4,208 0 5,762 Infil.: Win.: 25.3, Sum.: 19.8 257 3.020 777 1.271 823 327 Ductwork: 1,213 896 Room Totals: 6,198 823 6,985 C:1... 1Aprivate Res' 7-18-12.rhv Sunday, August 05, 2012, 2:42 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 19 Detailed Room Loads - Room 11 - Milsters Quarters (Average Load Procedure) General'-. Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 437.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 437.0 sq.ft. Supply Air: 297 CFM Ceiling Height: 10.5 ft. I Supply Air Changes: 3.9 AC/hr Volume: 4,589.0 cuft Req. Vent. CIg: 0 CFM Number of Registers: 3 I Actual Winter Vent.: 0 CFM Runout Air: 99 C F Percent of Supply.: 0 % Runout Duct Size: 6 in. M Actual Summer Vent.: 0 CFM Runout Air Velocity: , 504 ft./, in. Percent of Supply: 0 % Runout Air Velocity: 504 ft./�in. Actual Winter Infil.: 41 CFM Actual Loss: 0.163 in.w g./1 00 ft. Actual Summer Infil.: 32 CFM Item W. �0 Vft loft it � Loss J n_'-4� T ' HT in' Vq'n Z ; rl'� r� f- - - A N -Wall-Concrete Block 10.5 X 72.8 0.244 8 6.8 497 4.2 0 309 10.5 NE -Wall -Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 E -Wall-Concrete Block 12 X 10.5 96 0.244 6.8 656 4.2 0 408 SE -Wall -Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 S -Wall-Concrete Block 7 X 10.5 73.5 0.244 6.8 502 4.2 0 312 N -GIs-New Material shgc-0.3 37.5 0.650 18.2 682 16.1 0 603 100%S NE -GIs -New Material shgc-0.3 1 0.650 18.2 273 30.5 0 458 O%S i E -GIs-New Material shgc-0.3 30 0.650 18.2 546 38.6 0 1,158 O%S I SE -GIs -New Material shgc-0.3 15 0.650 18.2 273 30.3 0 454 O%S I Floor -Over Enclosed space 1 X 437 0.320 1.4 627 0.8 0 336 437 1 Subtotals for Structure: 4,568 0 4,356 Infil.: Win.: 40.7, Sum.: 32.0 415 3.021 1,253 1.271 1,326 527 Ductwork: 1,416 787 People: 200 ]at/per, 230 sen/per: 2 400 460 Room Totals: 7,237 1,726 6,130 C:X ... XAprivate Res'7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor � AIII& A Private Residence Fort Lauderdale, FL 33308 mull Page 20 11 Detailed Room Loads - Room 12 - Mosters Bath (Average Load Procedure) General' Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 185.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 185.0 sq. Supply Air: 126 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 3.9 AC/hr Volume: 1,943.0 cu. Req. Vent. CIg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 126 CF Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 473 ft./ in. Percent of Supply: 0 % Runout Air Velocity: 473 ft./fnin. Actual Winter Infil.: 28 CFM Actual Loss: 0.116 in.?vg./l 00 ft. Actual Summer Infil.: 22 CFM Item A 6 ng rea Detcript Wpanl' lty , .T I AM E -Wall-Concrete Block 9.8 X 102.9 0.244 6.8 703 4.2 0 437 10.5 SE -Wall -Concrete Block 6 X 10.5 48 0.244 6.8 328 4.2 0 204 S -Wall-Concrete Block 11 X 10.5 100.5 0.244 6.8 687 4.2 0 427 SE -GIs -New Material shgc-0.3 15 0.650 18.2 273 30.3 0 454 O%S S -GIs-New Material shgc-0.3 1 0.650 18.2 273 16.9 0 253 O%S i Floor -Over Enclosed space 1 X 185 0.320 1.4 265 0.8 0 142 185 Subtotals for Structure: 2,529 0 1,917 Infil.: Win.: 27.6, Sum.: 21.7 281 3.021 850 1.269 900 357 Ductwork: 822 335 Room Totals: 4,201 900 2,609 C:X ... XAprivate Res'7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rhvac -,Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor I A Private Residence Fort Lauderdale, FL 33308 00 Pa a 21 Detailed Room Loads - Room 13 - H r W.I.C. (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 160.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 160.0 sq. Supply Air: 71 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 2.5 AC/hr Volume: 1,680.0 cu. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 71 C M Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 520 ft. fmin. Percent of Supply: 0 % Runout Air Velocity: 520 ft. min. Actual Winter Infil.: 21 CFM Actual Loss: 0.223 in Wg./100 ft. Actual Summer Infil.: 16 CFM ' K.�� Sen I CfgDescription .: . s ; Quantityr Value ; HTLoss HiTM S -Wall-Concrete Block 6.9 X 72.5 0.244 6.8 495 4.2 0 308 10.5 W -Wall-Concrete Block 13 X 136.5 0.244 6.8 933 4.2 0 580 10.5 Floor -Over Enclosed space 1 X 160 0.320 1.4 230 0.8 0 123 160 Subtotals for Structure: 1,658 0 1,011 Infil.: Win.: 20.5, Sum.: 16.1 209 3.020 631 1.268 668 265 Ductwork: 557 188 Room Totals: 2,846 668 1,464 C:\ ...Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rh"vac-rResidential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 22 Detailed Room Loads - Room 14 - H S W. L C. (Average Load Procedure) Gerieralb ;,' r x `` `. 0111fil ''I! Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 88.0 ft. System Number: 2 Room Width: 1.0 ft. Zone Number: 2 Area: 88.0 sq. Supply Air: 55 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 3.5 AC/hr Volume: 924.0 cu Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 55 C M Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 626 ft. min. Percent of Supply: 0 % Runout Air Velocity: 626 ft. min. Actual Winter Infil.: 16 CFM Actual Loss: 0.441 in wg./100 ft. Actual Summer Infil.: 13 CFM Areal `{ U- Htg Nen� Clg Lat Seiie Descrlpfioq �34 _. Quantity f t Value ;, HTM HTM Galn Gain; S -Wall-Concrete Block 6 X 10.5 63 0.244 6.8 430 4.2 0 267 W -Wall-Concrete Block 9.8 X 102.9 0.244 6.8 703 4.2 0 437 10.5 Floor -Over Enclosed space 1 X 88 0.320 1.4 126 0.8 0 68 88 Subtotals for Structure: 1,259 0 772 Infil.: Win.: 16.3, Sum.: 12.8 166 3.020 501 1.272 530 211 Ductwork: 428 145 Room Totals: 2,188 530 1,128 C:1...\Aprivate Res' 7-18-12.rhv Sunday, August 05, 2012, 2:42 PM RhVac = Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 23 Detailed Room Loads - Room 15 - LOW Media Rm' (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 355.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 355.0 sq. Supply Air: 168 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 2.7 AC/hr Volume: 3,728.0 cu ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 84 C M Percent of Supply.: 0 % Runout Duct Size: 5 in Actual Summer Vent.: 0 CFM Runout Air Velocity: 617 ft. min. Percent of Supply: 0 % Runout Air Velocity: 617 ft.min. Actual Winter Infil.: 19 CFM Actual Loss: 0.313 in.wg./100 ft. Actual Summer Infil.: 12 CFM Arear`U- Htgw z^� ;� .Quantity .Value 5 ` HTMs HTM Gain Gain: SW -Wall -Concrete Block 7.7 X 80. 0.244 6.8 552 4.2 0 343 10.5 i W -Wall-Concrete Block 15 X 117.5 0.244 6.8 803 4.2 0 499 10.5 W -GIs-New Material shgc-0.3 40 0.650 18.2 728 38.6 0 1,544 0%oS UP -Cell -Custom Roof 355 X 1 35 0.032 0.9 318 1.3 0 454 Subtotals for Structure: 2,401 0 2,840 Infil.: Win.: 18.7, Sum.: 12.4 238 2.417 576 0.856 514 204 Ductwork: 808 681 Room Totals: 3,785 514 3,725 C:\ ...Wprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM RhVrac : Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor I A Private Residence Fort Lauderdale, FL 33308 F0 Page 24 Detailed Room Loads - Room 16 - ostrom (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 243.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 243.0 sq ft. Supply Air: 602 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 14.1 AC/hr Volume: 2,552.0 c ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 0 CFM Runout Air: 120 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in'. Actual Summer Vent.: 0 CFM Runout Air Velocity: 450 ft]/min. Percent of Supply: 0 % Runout Air Velocity: 450 ft�/min. Actual Winter Infil.: 60 CFM Actual Loss: 0.105 in.wg./100 ft. Actual Summer Infil.: 40 CFM Item3a K r l' i `.�x �KAr�ea `U;r�Htg t Sen.., Clgr; 1 4 Lat'�`Sen: Descrl ValuenrFSHTMI;;. p QuaritltY' Loss r. F�,G_ TM am �_hGaln S -Wall-Concrete Block 5.5 X 57.8 0.244 6.8 395 4.2 0 245 10.5 SW -Wall -Concrete Block 12.5 X 31.2 0.244 6.8 214 4.2 0 133 10.5 W -Wall-Concrete Block 6 X 10.5 63 0.244 6.8 430 4.2 0 267 NE -Wall -Concrete Block 12 X 72 0.244 6.8 492 4.2 0 306 10.5 E -Wall-Concrete Block 25 X 10.5 100.5 0.244 6.8 687 4.2 0 427 SE -Wall -Concrete Block 12 X 72 0.244 6.8 492 4.2 0 306 10.5 SW -GIs -New Material shgc-0.3 100 0.650 18.2 1,820 16.1 0 1,607 100%S NE -GIs -New Material shgc-0.3 54 0.650 18.2 983 30.5 0 1,647 0%S E -GIs-New Material shgc-0.3 62 0.650 18.2 2,949 25.3 0 4,104 58%S (3) SE -GIs -New Material shgc-0.3 54 0.650 18.2 983 16.1 0 868 100%S UP-Ceil-Custom Roof 243 X 1 243 0.032 0.9 218 1.3 0 311 Subtotals for Structure: 9,663 0 10,221 Infil.: Win.: 60.2, Sum.: 39.8 767 2.417 1,853 0.856 1,652 656 Ductwork: 3,124 2,433 Room Totals: 14,640 1,652 13,310 C:\ ...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM Rh ac !Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 10 Page 25 Detailed Room Loads - Room 17 - P BAW (Average Load Procedure) General;; .. . - -. �, .. .. ,_ . •,.. , . .., , Calculation Mode : Htg & clg. Occurrences: 1 Room Length: 366.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 366.0 sq ft. Supply Air: 257 CFM Ceiling Height: 10.5 ft.l Supply Air Changes: 4.0 AC/hr Volume: 3,843.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: F 128 C M Percent of Supply.: 0 % Runout Duct Size: 7 i Actual Summer Vent.: 0 CFM Runout Air Velocity: 480 /min. Percent of Supply: 0 % Runout Air Velocity: 480 ./min. Actual Winter Infil.: 40 CFM Actual Loss: 0.120 in.wg./100 ft. Actual Summer Infil.: 26 CFM e�ar r.�� Htg Sen CIg flat;T S�en Descrlptibny - _rQuanfity`` r „" glue, r� :. _ ` HTM ' ,, Lossx,=, HTM:�Galn k)i..'�. G_ aln N -Wall-Concrete Block 5 X 10.5 37.6 0.244 6.8 256 4.2 0 159 NE -Wall -Concrete Block 15.8 X 135.1 0.244 6.8 928 4.2 0 577 10.5 E -Wall-Concrete Block 10.5 X 1102 0.244 6.8 753 4.2 0 468 10.5 SE -Wall -Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 W -Wall-Concrete Block 12 X 1 6 0.244 6.8 861 4.2 0 535 10.5 N -GIs-New Material shgc-0.3 15 0.650 18.2 273 16.1 0 241 100%S NE -GIs -New Material shgc-0.3 30 0.650 18.2 546 30.5 0 915 0%S SE -GIs -New Material shgc-0.3 15 0.650 18.2 273 30.3 0 454 0%S UP-Ceil-Custom Roof 366 X 1 366 0.032 0.9 328 1.3 0 468 Subtotals for Structure: 4,474 0 3,976 Infil.: Win.: 39.8, Sum.: 26.3 507 2.417 1,226 0.856 1,093 434 Ductwork: 1,546 1,038 People: 200 lattper, 230 sen/per: 1 200 230 Room Totals: 7,246 1,293 5,678 C:\...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM R vac t Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Pa a 26 Detailed Rooml oads - Room 18 - IP Bath (Average Load Procedure) IND Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 80.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 80.0 s , .ft. Supply Air: 49 CFM Ceiling Height: 10.5 ft Supply Air Changes: 3.5 AC/hr Volume: 840.0 c .ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 49 CFM Percent of Supply.: 0 % Runout Duct Size: 4 ip. Actual Summer Vent.: 0 CFM Runout Air Velocity: 563 ft./min. Percent of Supply: 0 % Runout Air Velocity: 563 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.358 1 in.wg./100 ft. Actual Summer Infil.: 4 CFM Area, " -U- Htg SenW Lat ` Seri' DescrAiption'> > > 0 Quanti`'� Value HTM Loss Gain :. Gaim W -Wall-Concrete Block 7 X 10.5 611.5 0.244 6.8 420 4.2 0 261 W -GIs-New Material shgc-0.3 2 0.650 18.2 218 38.6 0 463 0%S [80 UP-Ceil-Custom Roof 80 X 1 0.032 0.9 72 1.3 0 102 Subtotals for Structure: 710 0 826 Infil.: Win.: 5.8, Sum.: 3.8 74 2.422 178 0.857 158 63 Ductwork: 241 199 Room Totals: I I I 1,129 158 1,088 C:\ ...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM . 11 R vac = Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor t A Private Residence Fort Lauderdale, FL 33308 Page 27 Detailed Room Loads -Room 19 -W.I.C. (Average Load Procedure) General� ,.t. ._ ` s .�� « , ,., . 1 - -.. Calculation Mode: Htg. & clg. I Occurrences: 1 Room Length: 50.0 ft System Number: 3 Room Width: 1.0 Zone Number: 3 Area: 50.0 q.ft. Supply Air: 4 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 0.4 AC/hr Volume: 525.0 u.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 4 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 41 ft./min. Percent of Supply: 0 % Runout Air Velocity: 41 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.002 in.wg./100 ft. Actual Summer Infil.: 0 CFM x° Descflpfion r' f�'t,. uaiititj\%alueA °: , HTM Loss HTM Gain . Galni; UP-Ceil-Custom Roof 50 X 1 150 0.032 0.9 45 1.3 0 64 Subtotals for Structure: 45 0 64 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 12 14 Room Totals: 57 0 78 C:1... 1Aprivate Res' 7-18-12.rhIL Sunday, August 05, 2012, 2:42 PM Rillivac t Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 28 Detailed Room Loads - Room 20 - PIRm #2 (Average Load Procedure) '� Calculation Mode: Htg. & c1g. Occurrences: Room Length: 3180 ft System Number: 3 Room Width: 1.0 Zone Number: 3 Area: 318.0 sq.ft. Supply Air: 242 CFM Ceiling Height: 10.5 A. Supply Air Changes: 4.4 AC/hr Volume: 3,339.0 C'U.ft. Req. Vent. CIg: 0 CFM Number of Registers: 2 I Actual Winter Vent.: 0 CFM Runout Air: 121 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 454 ft./min. Percent of Supply: 0 % Runout Air Velocity: 454 ft./min. Actual Winter Infil.: 32 CFM Actual Loss: 0.107 in.wg./l 00 ft. Actual Summer Infil.: 21 CFM _1_ _11 t- ",SdlN'01gguen Item likkAl ID9 1 - Descr1P 10M?" Value TmmOT J4 in N -Wall-Concrete Block 10.6 X 1111.3 0.244 6.8 760 4.2 0 473 10.5 1 NE -Wall -Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 E -Wall-Concrete Block 12 X 10.5 i101 0.244 6.8 690 4.2 0 429 SE -Wall -Concrete Block 5 X 10.5 37.5 0.244 6.8 256 4.2 0 159 S -Wall-Concrete Block 7 X 10 70 0.244 6.8 478 4.2 0 297 NE -GIs -New Material shgc-0.3 15 0.650 18.2 273 30.5 0 458 O%S E -GIs-New Material shgc-0.3 25 0.650 18.2 455 38.6 0 965 O%S SE -GIs -New Material shgc-0.3 15 0.650 18.2 273 30.3 0 454 O%S UP-Ceil-Custom Roof 318 X 1 318 0.032 0.9 285 1.3 0 407 Subtotals for Structure: 3,726 0 3,801 Infil.: Win.: 32.4, Sum.: 21.4 412 2.418 997 0.856 889 353 Ductwork: 1,281 981 People: 200 lat/per, 230 sen/per: 1 200 230 Room Totals: 6,004 1,089 5,365 vC:\ ...\Aprivate Res'7-18-12.rhSunday, August 05, 2012, 2:42 PM ' Rhvac = Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 29 Detailed Room Loads - Room 29 -)Bath #2 (Average Load Procedure) General; �`�:�.� '�"`<����:.. = �•, -� _� -z,..�• �� Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 84.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 84.0 sq.ft. Supply Air: 6 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 0.4 AC/hr Volume: 882.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 6 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 68 ft./min. Percent of Supply: 0 % Runout Air Velocity: 68 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.006 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U- HtgWISnWHTM aLa Se Quamtity Valle , HTMs, Galnr Gain,, UP-Ceil-Custom Roof 84 X 1 84 0.032 0.9 75 1.3 0 108 Subtotals for Structure: 75 0 108 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 20 24 Room Totals: 95 0 132 C:\ ...\Aprivate Res' 7-181 12.rhv Sunday, August 05, 2012, 2:42 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 30 Detailed Room Loads -Room 22 - .l. C. #2 (Average Load Procedure) ti• { Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 84.0 System Number: 3 Room Width: 1.0 Zone Number: 3 Area: 84.0 'sq.ft. Supply Air: 6 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 0.4 AC/hr Volume: 882.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 6 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 68 ft./min. Percent of Supply: 0 % Runout Air Velocity: 68 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.0016 in.wg./100 ft. Actual Summer Infil.: 0 CFM �Itey Area -U- Htg Sen Clg Lat ff Sen®e�scrlption ,ir. Quantity, «$Value HTM Loss HTMain Gain. UP -Cell -Custom Roof 84 X 1 84 0.032 0.9 75 1.3 0 108 Subtotals for Structure: 75 0 108 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 20 24 Room Totals: 95 0 132 C:1... 1Aprivate Res' 7-18-12Trhv Sunday, August 05, 2012, 2:42 PM RKv—ac- Residential & Light Commercial HVAC Load S Elite Software Development, Inc. Richard Taylor 1*10 A Private Residence Fort Lauderdale, FL 33308 - Paae 31 Detailed Room Loads - Room 23 - #3 (Average Load Procedure) GO nbral Room Length: 320.0 System Number: 3 Room Width: 1.0 Zone Number: 3 Ceiling Height: 10 ' 5 ft " Supply Air Changes: 4.3 AC/hr Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 452 ft./min. Percent of Supply: 0 % Runout Air Velocity: 452' ft./min. Actual Winter Infil.: 32 CFM Actual Loss: 0.106 in.wg./l 00 ft. Actual Summer Infil.: 21 CFM Ilk M Dos' an 4L 1,17 R vacs Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor ` A Private Residence Fort Lauderdale, FL 33308 Page 32 Detailed Room Loads - Room 24 - 8ath #3 (Average Load Procedure) f , • ��• : �' � �. • �.. :.� : .� �: � -��:::, ,�`�?' � zr-� , ;ter-."; . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 78.0 fill System Number: 3 Room Width: 1.0 Zone Number: 3 Area: 78.0 �q.ft. Supply Air: 64 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 4.7 AC/hr Volume: 819.0 1 u.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 64 CFM Percent of Supply.: 0 Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 469 ft./min. Percent of Supply: 0 % Runout Air Velocity: 469 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.182 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item a Areal Senp Q.uantl s;'Value HTM LosIMC16 Gain;, Galn:, W -Wall-Concrete Block 12 X 114 0.244 6.8 779 4.2 0 484 10.5 W -GIs-New Material shgc-0.3 12 0.650 18.2 218 38.6 0 463 0%S UP-Ceil-Custom Roof 78 X 1 78 0.032 0.9 70 1.3 0 100 Subtotals for Structure: 1,067 0 1,047 Infil.: Win.: 9.9, Sum.: 6.5 126 2.421 305 0.857 272 108 Ductwork: 372 258 Room Totals: 1,744 272 1,413 C:\ ...\Aprivate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM R vac'- Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Pa a 33 Detailed Room Loads - Room 25 - .I.0 #3 (Average Load Procedure) General: 3t. Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 50.0 ft. System Number: 3 Room Width: 1.0 . Zone Number: 3 Area: 50.0 q.ft. Supply Air: 42 CFM Ceiling Height: 10.5 Supply Air Changes: 4.9 AC/hr Volume: 525.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 42 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 487 ft./min. Percent of Supply: 0 % Runout Air Velocity: 487 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.268 in.wg./100 ft. Actual Summer Infil.: 7 CFM Htg Sen Clg Lat Sen Desc�lption�,, , , :, " . Quantity f;valtae . HTM Loss HTM Gain Gala' S -Wall-Concrete Block 6.8 X 10 68 0.244 6.8 465 4.2 0 289 W -Wall-Concrete Block 7 X 10 70 0.244 6.8 478 4.2 0 297 UP-Ceil-Custom Roof 50 X 1 50 0.032 0.9 45 1.3 0 64 Subtotals for Structure: 988 0 650 Infil.: Win.: 10.8, Sum.: 7.2 138 2.420 334 0.855 297 118 Ductwork: 359 172 Room Totals: 1,681 297 940 C:1... Vlprivate Res' 7-18-12.r , v Sunday, August 05, 2012, 2:42 PM ' R vac` Residential & Light Commercial HVAC Loads Richard Taylor Elite Software Development, Inc. A Private Residence Fort Lauderdale, FL 33308 Page 34 Detailed Room Loads - Room 26 - all/CI' (Average Load Procedure) Generale:'° y r'`' Calculation Mode: Htg. & clg. I Occurrences: 1 Room Length: 45.0 ft. System Number: 3 Room Width: 1.0 ft. Zone Number: 3 Area: 45.0 sq.ft. Supply Air: 18 CFM Ceiling Height: 10.5 ft. Supply Air Changes: 2.3 AC/hr Volume: 473.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 18 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 207 ft./min. Percent of Supply: 0 % Runout Air Velocity: 20�7 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.050 in.wg./100 ft. Actual Summer Infil.: 3 CFM Arrea -U- Htg Sen Clg Lat Sep" Description Quantity Value HTM Loss HTM Gain . GalnI W -Wall-Concrete Block 5 X 10.5 52.5 0.244 6.8 359 4.2 0 223 UP-Ceil-Custom Roof 45 X 1 45 0.032 0.9 40 1.3 0 58 Subtotals for Structure: 399 0 281 Infil.: Win.: 4.1, Sum.: 2.7 53 2.419 127 0.857 113 45 Ductwork: 143 73 Room Totals: 669 113 399 C:\ ...1Aprivate Res' 7-18-1,2.rhv Supday, August 05, 2012, 2:42 PM A ,9 R. vac - Residential $ Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Pa a M System 1 Room Load Summary Htg Min Run. R.un Clg, .Clg Min Act Room Area Sens Htg ' Duet- Duct{ • rt Sens', rLat Clg a i Sys No Name SF Btuh CFM Size Vell Btuh Btuh CFM CFM --Zone 1-- 1 Vestibule /Stairs 202 13,745 179 3-6 532 6,832 1,628 311 313 4 Kitchen 335 2,16q 28 2-7 488 5,688 1,386 259 261 5 Breakfast Area 385 8,236 107 4-6 513 8,779 1,155 399 403 6 Pantry 32 0 0 0-0 0 0 0 0 0 7 Pd' Rm' 27 0 0 0-0 0 0 0 0 0 8 Laundry 67 2,807 36 1-5 621 1,845 499 84 85 9 Hall/Elevator 259 7,463 97 2-6 607 5,197 1,233 236 238 Duct Latent 3,514 System 1 total 1,307 34,415 447 28,341 9,415 1,289 1,300 System 1 Main Trunk Size: 12x18 in. Velocity: 1867 ft./min Loss per 100 ft.: 0.105 in.wg Cooling System Summary Coolin g Sensible/Latent Serislble .. Latent Total Tons 'split Btuh` :'Btuh"' Btuh Net Required: 3.15 75% / 25% 28,341 9,415 37,756 Equipment Data Heatincl System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: Capacity: 0 0 Sensible Capacity: n/a 0 Btuh Latent Capacity: I n/a 0 Btuh C:\ ...\Aprivate Res' 7-18-12.rhvl Sunday, August 05, 2012, 2:42 PM .a , v c = Residential & Light Commercial HVAC Loads Richard Taylor Oil Elite Software Development, Inc. A Private Residence Fort Lauderdale, FL 33308 Page 36 System 2 Room Load Summary Room Area -Sens Htg Min Htg Runk Duct" Run Clg Duct `` Sens` ;Clg yLat " Min Glg Act Sys No Name SF Btuh' CFM Size Vel Btuh Btuh' CFM CFM --Zone 2- 2 Great Room 526 12,4131 161 6-6 586 14,238 1,890 648 690 3 Vest'/Coats/CI' 81 900 12 1-4 258 465 235 21 23 10 Foyer 243 6,198 81 3-6 575 6,985 823 318 339 11 Masters Quarters 437 7,231 94 3-6 504 6,130 1,726 279 297 12 Masters Bath 185 4,2g1 55 1-7 473 2,609 900 119 126 13 Her W.I.C. 160 2,846 37 1-5 520 1,464 668 67 71 14 HIS W.I.C. 88 2,188 28 1-4 626 1,128 530 51 55 Duct Latent 1,018 System 2 total 1,720 35,983 468 33,018 7,790 1,502 1,600 System 2 Main Trunk Size: 16x16 in. Velocity: 900 �0.099 ft./min Loss per 100 ft.: in.wg Cooling System Summary Cooling Sensible/Latent Sensible; Latent- Total Tons Split Btuh Btuh " Btuh Net Required: 3.40 I 81% / 19% 33,018 7,790 40,808 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: Capacity: 0 0 Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:1 ... XAprivate Res' 7-18-12.r i v Sunday, August 05, 2012, 2:42 PM ,q i nvac7- Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Richard Taylor A Private Residence Fort Lauderdale, FL 33308 Page 37 System 3 Room Load Summary Htg - Min Run Run Clg Clg. Min Act - Room Area Sens Htg Duct Duct' Sens Lat 'Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM —Zone 3- 15 Loft/ Media Rm' 355 3,785 49 2-5 617 3,725 514 169 168 16 Rostrom 243 14,640 190 5-7 450 13,310 1,652 606 602 17 VIP B/Rm' 366 7,246 94 2-7 480 5,678 1,293 258 257 18 VIP Bath 80 1,129 15 1-4 563 1,088 158 49 49 19 W.I.C. 50 57 1 1-4 41 78 0 4 4 20 B/Rm #2 318 6100JJ 78 2-7 454 5,365 1,089 244 242 21 Bath #2 84 95 1 1-4 68 132 0 6 6 22 W.I.C. #2 84 95 1 1-4 68 132 0 6 6 23 B/Rm #3 320 5,980 78 2-7 452 5,350 1,084 243 242 24 Bath #3 78 1,744 23 1-5 469 1,413 272 64 64 25 W.I.0 #3 50 1,681 22 1-4 487 940 297 43 42 26 Hall/CI' 45 669 9 1-4 207 399 113 18 18 Duct Latent 1,741 stem 3 total 2,073 43,127 561 37,611 8,213 1,711 1,700 System 3 Main Trunk Size: 18x18 in. Velocity: I756 ft./min Loss per 100 ft.: 0.060 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.82 82% / 18% 37,611 8,213 45,823 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: Capacity: 0 Sensible Capacity: /a 0 Btuh Latent Capacity: /a 0 Btuh C:\ ...\Apdvate Res' 7-18-12.rhv I Sunday, August 05, 2012, 2:42 PM