HomeMy WebLinkAboutPOOL LAYOUT & PIPING PLAN6" RAISED SPA 18" BENCH - 20" BELOW W.L. (8) THERAPY JETS (2) FILTERED INLETS AQUASTAR 32CDFL 32" CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE OR EQUAL (1) SPA LIGHT (1) 36" WIDE SPILLWAY JANDY - SPA SIDE BUTTON / FIELD VERIFY LOC. HEAT PUMP - UNDER STAIR! n EQUI, 7 SEE SITE P 24"RAISED - 8" THICK POOL WALL W/ #4 DIA. REBAR @ 12" O.C.E. PROVIDE 48" MIN. HIGH FENCE PER LOCAL 11 26' CODE 8c LOOPLOC POOL COVER Q I I PER MFGR'S SPECS O PER 2010 FLORIDA BUH.DING CODE - r�l RESIDENTIAL CHAPTER 41. / g" 81' EX. HOUSE COLUMNS m' = 11jorA 5' REINFORCED CONC. SLAB(S) (FEILD VERIFY SIZE & LOCATION) 13'-0" NAVD (14.5 NGVD) F.F. HT. -J i 1p — Y rlyl.— r & 2.5" SCH 40 IF 3" CH � 40 \ � I 13.08' 6" RAISED - 8' THICK SPA WALLS STEPS W/ HANDRAIL 240 SQ. IN. MIN. —'TOP TREAD 1 S z KfM,IER (3) LION HEAD SPITTERS W/ 1" SUPPLY LINES AND VALVES 18'-4/1 HANDHOLDS @ 48" (3) INLETS MAX. SPACING alz (118" DIA. MAIN DRAINS 81 O TIED TOGETHER - 36" APART wl� (DRAINS ANSIA/M8IA 10W/ O �*7Ip 200 GPM.(? 1.48 FT/SEC. MIN. FLOW THRU EACH GRATE) I VI� 4"SCH 40 STUB -OUT FOR LIGHT POOL CLEANER 13' LADDER _ 1011 PERIMETER BONDING WIRE @ 18"MIN. - 24" MAX. FROM W.L. (SEE DETAIL) 2" SCH 40 - — - - — - POOL STRUCTURE LIMIT LINE \( 12.58' —C— N.A.V.D. I I 146 I EX. HOUSE I COLUMNS I � 2.§" SCH 40 112.58' I � �� I A� I f 12.SOn 3" SCH 40 / 13'-0" NAV (14.5 NGVD) .F. HT. RESIDENCE POOL LAYOUT & PIPING PLAN 1/4"=1'-0" 13'-4" NAVD (IU NGVD) F.F. HT. h A4una al n71S As olmmv'K` 75 W4 py v� - M fK G G o .G. a � aAi o 4, T LL o .z ° 0 z N • F-1 .-i tl7 � •. iFi M o � �Vov'o0 o a a U A z • � a z F � a O z DRAWN BY: MAP CHECKED BY: waC DATE: 1-20-14 SCALE: AS NOTED iOB NUMBER: 3 - 205 SHEET 1 OF 3 FA DEPARTMENT OF ENVIROMENTAL PROTECTION CERTIFICATIONS The design plans and specifications submitted as part of the permit applicaion are in compliance with the standards established in rule 62B-33.007, Florida Administrative Code. The main wind -force resisting system has been designed in accordance with ANSUASCE 7-88, minimum design loads for buildings and other structures, section 6, to withstand the wind loads associated with a minimum basic wind speed of 140 miles per hour. The components and cladding have been selected and their use incorporated into the design and specifications in accordance with ANSUASCE 7-88, minimum design loads for buildings and other structures, section 6, to withstand the wind loads associated with a minimum basic wind speed of 140 miles per hour. 11' 11' This pool has been designed not to increase the risk of damage to adjacent dwelling during coastal storm events. 3' 4' 24"RAISED - 8" THICK POOL WALL 1 I I POOL STRUCTURE LIMIT LINE I I I I --- - - - - - ---i---- ---- --- --- I 91 Z 6" RAISED - I OI O I 14" DIA. AUGER CAST PILE 811 WALLIS K SPA 1%' I rJ,l I (8 REQUIRED) 1 OI U I 12" POOL 15 TON DESIGN CAPACITY O 30 TON ULTIMATE CAPACITY EX. HOUSEi� FLOOR COLUMNS I al I �� I wl I I WI I _SEX. HOUSE ------�--Ui— — — l— — — — — — COLUMNS s I I I 4 6" POOL 6" POOL 2 a WALLS I l I WALLS t % 1 I I s 6" POOL 1 4 s v 5 I WALLS \\ CONTROL LINE PILING NOTES: - RECESS PILING 3" INTO BOTTOM OF POOL FLOOR (TYP.) - PILE REINFORCING (NOT SHOWN) IS TO BE SPECIFIED BY PILING ENGINEER - PILING STEEL TO BE BENT INTO POOL FLOOR AND TIED TO BOTTOM MAT OF STEEL #4 DIA. REBAR @ 12" O.C.E.W. 6" POOL Scale: 1/4 "=1' 26' ING LAYOUT 4t 18' 4' PILING STEEL TO BE BENT F—61 t INTO POOL FLOOR AND TIED TO BOTTOM MAT OF STEEL %I W.L. 1 9' #4 DIA. REBAR LOPE 1' @ 6" O.C.E.W. TOP MAT ONLY 41 _ 111 t .,. r 7, =III=III III _=_ =III=III I I=LI I=III=III=III=III=III=III=1 ll1=1 I I I-11511=I1=1 I I—III 12" III-1 11=III,=i71111 ITI ICI ITI 1= _I I I I I I i I I 11 i III I I I ITI I I I i I —I I I 1=TTi=1Tf=1 I i T iTi= RECESS PILING 3" —� INTO BOTTOM OF POOL FLOOR (TYP.) POOL SECTION TYPE 'O' POOL SCALE: 3/8" = F-0" #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT ONLY , RESIDENCE 611 12.58' N.A.V.D. OF POOL SHELL 14" DIA. AUGER CAST PILE (8 REQUIRED) 15 TON DESIGN CAPACITY 30 TON ULTIMATE CAPACITY NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS, POOL LAYOUT LOCATION AND POOL ELEVATIONS PRIOR TO CONSTRUCTION @ 12" O.C.E.W. IN WALLS #4 DIA. REBAR @ 12" O.C.E.W. BOTTOM MAT ONLY -26.92' N.A. TIP OF SH2 ENGINEER (TYP.) PILE BY 7' SPA SECTION SCALE: 3/8" =1'-0" #4 DIA. REBAR @ 12" O.C.E.W. IN WALLS #4 DIA. REBAR @ 6" O.C.E.W. TOP MAT ONLY r4 M •� C �z v � o � u a aAi o � W O 6C 21� _�w * a <to - � r C-3 �� aQ�*�` M � M r` 'Qi V M � V in 0 96x z . �a zZ oz z� � �o F V a � HF a� O z DRAWN BY: MAP CHECKED BY: WJC DATE: 1-20-14 SCALE: AS NOTED JOB NUMBER: 13 - 205 SHEET 2 OF 3 SAND SET, INTERLOCKING PAVER DECK - BULLNOSE BRICK COPING @ X" PER. FOOT 3" rlLOP�(MDEIK 2-#4 DIA. +TOP. OF BEAM PACTED CLEAN FILL N X.;95%DRY DENSITY) MARCITE ORE UAL Il\ REINFORCING STEEL (SEE SHEET 2) lY, RADRUS VARIES TYPICAL WALL SECTION 18" MIN: 24" MAX. (ENTIRE PERIMETER) W.L. , , -*ZBELOW 4 -6' #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS III I I- SUB -GI (ONE ON EACH S[DE OF POOL-41OTAL) III -I. I -I 4" THICK x Y WIDE 2500 P.S.I. CONCRETE SLAB W'/ (I) #8 RARE COPPER WIRE (UNDER SLAB) BONDED TO POOL STEEL AS SHOWN EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF N.E.C. 2008 SEC. 680.26 1�- HANDHOLD SHALL BE ACCESSffi E WITHIN 4 FEE] NOTTOEXCEED8FEETATJECEEDS " POINTS ALONG THE INSIDE OF THE L PERIMETER WHERE THE WATER DEPTH 4 FEET HANDHOLD DTAIL (WHEN APPLICABLE) 11-11 I I I WATER LINE IE 14" II,- IS" r II III I � a PIPE REDUCED TO I" a AND RUN TO DECK +t BOX I e B TING DARK CONTRA: CAP TILE II' VACUUM FITTING W/ _ SELF -CLOSING SAFTY COVER (HAYWARD MODEL #400) 2" SCH 40 PVC CORD I LI- LED LIGHT SLEEVE'- SP 10-22 WALL VACUUM LINE DETAIL FITTING (NIMEN APPLICABLE) INSTALLED INSIDE BENCH SECTION PIPE (WHEN APPLICABLE) LED LIGHT DETAIL 4" MIN. SKMMER COVER W/ WRAP (2) 93 INA. AROUND ADJUSTABLE COLLAR SKIMMER, TIED TO POOL STEEL LEAF BASKET TOPOOLPUMP 20 GPM MIN. FLOW SKIMMER DETAIL CROSS BRACE I 28'° MIN.- 40" MAX. 12" 1211 1211 ANCHOR W/ 12" MAX. ESCUTCHEON WATER LINE 3 "- 6" MAX ANCHOR W/ #8 BOND 8.4" WIRE & APPR. BOND CLAMP 8.4.I - TREADS TO BE ' 24" X 30" X 12" DEEP SLIP -RESISTANT 24" X 30" X 12" DEEP 8.4" I -I CONC. PAD W/ 3 - #3 DIA. t III- STUBBED OUT OF POOL WALL 2' CONC. PAD W/ 3 - #3 DIA. END CAPS I STUBBED OUT OF POOL WALL 2 8.4„ I 12" O.C. & 3 - #3 DIA. CONT. REQUIRED @ 12" O.C. & 3 - #3 DIA. CONT. 8.4" A@NCHOR W/ #8 BOND . y� WIRE & APPR. BOND Ladder Detail y_j CLAMP STEP SECTION POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMt CURVE) REC. PUMP = 2 HP JANDY E-PUMP JEP 2.0 VARIABLE SPEED - LOW SPEED = 36 GPM M HIGH SPEED =150 GPM @ 50 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./ EC. (6 FT./SEC. MAX. - PRESSURE LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT. EC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 27.6 GPM @ 0.375 GPM/ Q. FT. = 73.6 SQ. FT. FILTER AREA THERAPY PUMP = 2 HP JANDY PLUS HP PHPM VARIABLE SPEED - LOW SPEED = 36 GPM M HIGH SPEED = 165 GPM @ 35 TDH 3" SUCTION PIPE @ 165 GPM = 7.29 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 82.5 GPM = 5.64 FT /SEC. (6 FT./SEC. MAX. - PRESSURE LINES) 3" PRESSURE PIPE @ 165 GPM = 7.29 FT. EC. (10 FT./SEC. MAX. - PRESSURE LINES) IS HEAT PUMP. W/ (3) 46CU& 2 HP JANDY PLUS HI' PUMP MOTOR w/ (1) #10 CU GROUND IN V CONDUIT BUILT-IN OVERLOAD SWITCH W/ 3 - #10 TURN CU WITHIN 1/2" MIN. CONDUIT 60 AMP POOL PANEL W/ MANUAL MOTOR STARTER SWITCH 3 - #6 TURN CU WITHIN %" ELEC. CONDUIT 2 HP JANDY E-PUMP MOTOR w/ BUILT-IN #8 SOLID CU GROUND WIRE OVERLOAD SWITCH W/ 3 - #10 TURN CU TO EXIST. PANEL WITHIN Y2" MIN. CONDUIT IME CLOCK S.............. P.S........... T. TOGGLE W. P. DISCONNECT SWITCH 12 VOLT TRANSFORMER POOL LIGHT -' ( GFI NOT REQUIRED) JUNCTION BOX (1) SPA LIGHT (GFI NOT REQUIRED) - I.ALL ELECTRICAL TO COMPLY WITH 2O08 NATIONAL ELECTRIC CODE. 2. 3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LIGHT(S), 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I.OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC680.22(B). ELECTRICAL DIAGRAM N.T.S. NOTE: REMOVE GRATE AND WELL POINT PLUG FROM MAIN DRAIN AND ATTACH AUX. PUMP LINE WHEN EMPTYING POOL POOL STEEL 0- 0 PUMP FRAME OR FILTER TANK MOUNT OR HEATER 1 3/4" x 3116" TAPCONS USED AT POOL PUMP AND FILTER 4" THICK REINFORCED CONCRETE SLAB 2" MIN. FAPU♦vD FILTER \�� POOL PUMP, FILTER AND HEATER ANCHOR POINTS -TYPICAL SIMPSON HGAIO HURRICANE TIE -DOWN Iv/ 2 - 1 1/4"x 3/16" STAINLESS STEEL TAPCONS IN SLAB & 2 - 3/16" STAINLESS STEEL SHEET METAL SCREWS IN BEATER - TYPICAL AS SHOWN OR SEE MANUFACTURER'S TIE -DOWN DETAIL. ANCHORING SYSTEM DESIGNED TO MEET FLORIDA BUILDING CODE 2010 170 MPH (ULT.), 132 M.P.H. (ASD) 3 SECOND GUST EXPOSURE D.) POOL EQUIPMENT ANCHORING DETAIL SEE MFGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION - HEATER SHAPE MAY VARY POOL SPECIFICATIONS SIZE: MIX 26' DEPTH: Y TO 4'-11" VOLUME: 9,950 GALLONS ELEVATION: DET. ON SITE TURN OVER RATE: 4.60 HR. (a, 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.10 HR. Ca, 150 GPM - HIGH SPEED) DESIGN FLOW RATE: = 9,950 GAL./6 HRS./60 MIN. = 27.6 G.P.M. TILE: STANDARD THERAPY JETS: (6) IN SPA POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POOL (3) SPA (2) DECK: PAVERS ELECTRIC: BY OTHERS POOL LIGHT: LED SPA LIGHT: LED LADDER: NO HANDRAIL: NO PUMP: 2 HP JANDY PLUS - PHPM A.P.S.P. PUMP CERT.: CURVE A - 34 GPM @ 1725 RPM FILTER: JANDY CS250 CARTRIDGE - 250 SQ. FT. FILTER AREA HEATER: JANDY EE2500 HEAT PUMP VACUUM LINE: YES POOL AREA: 305 S.F. PERIMETER 80 L.F. SPA AREA: 49 S.F. PERIMETER 28 L.F. JANDY RS4 ONE -TOUCH CONTROL SYSTEM (2) 8" DIA. MAIN DRAINS TIED TOGETHER - 36" APART (DRAINS TO BE COMPLIANT W/ /ASME/ANSI A112.19.8-2007 200 GPM @ 1.48 FT/SEC. MIN. FLOW THRU EACH GRATE) 3" SCH 40 PVC SUCTION TO PUMP (31' SCH 80 WHEN REQUIRED) MAIN DRAIN DETAIL N.T.S CV i T- 1 rA_m0 EQUIPMENT LAYOUT SCALE: N.T.S. LEGEND 1. 3" RETURN TO JETS 2.3" SPA MAIN DRAIN LINE 3.3" SPA MAIN DRAIN LINE 4.2" VACUUM LINE 5.3" POOL MAIN DRAIN LINE 6.2" SKIMMER LINE 7. 1" LION HEAD SUPPLY LINES S. 3" POOL RETURN LINE 9.3" SPA RETURN LINE A. 2 HP JANDY THERAPY E-PUMP B. 1.5" TO WASTE OR DISCHARGE TO GROUND C. 2 HP JANDY PLUS HP PHPM REC. PUMP W/ APPR HAIR & LINT STRAINER D. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE E. JANDY EE2500 HEAT PUMP W/ INTERNAL BY-PASS F. VALVES (TYPICAL) GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE M GROUNDED PER CODE. ' M 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. �.�y U 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTMA-615, GRADE 60, STEEL SHALL W BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. o 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. U 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. F S. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER V W DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS C) DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM W Z NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN py OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT.Qn 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE 2010 FLORIDA BUILDING CODE - RESIDENTIAL, SECTION R4101-PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. a 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH 2O10 FLORIDA BUILDING CODE - RESIDENTIAL R4101.17. w 12. SOIL STATEMENT - IN ACCORDANCE WITH FBC 2010 SECTION 1818, HVHZ [[y~ BEARING CAPACITY OF SOIL: BASED UPON RATIONAL ANALYSIS,THE IN -PLACE BEARING CAPACITY OF THE SOIL BENEATH THE POOL SHALL BE 550 PSF AND 2000 PSF FOR RELATED STRUCTURES SHOWN WITHIN THESES PLANS AFTER EXCAVATION AND COMPACTION IN I/1- ACCORDANCE WITH CURRENT EDITION OF FBC. SHOULD ANY MUCK, MARL, - LFi�•J OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD pi BE REMOVED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND W THE ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT AN INSPECTION.STRUCTURAL ELEMENTS ARE DESIGNED WITH A REQUIRED BEARING CAPACITY AS STATED ABOVE, UNLESS OTHERWISE SPECIFIED. FIBERGLASS AND VINYL LINER POOLS REQUIRE 250 PSF SAFE E0 BEARING CAPACITY UNLESS OTHERWISE SPECIFIED. Q 13. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES ACCRUE) 14. POOL PLANS ARE DESIGNED TO MEET THE 2010 FLORIDA BUILDING F CODE - RESIDENTIAL -CRATER 41 SWIMMING POOLS -SECTION R4101.6. 15. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN pw ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP 7-2006 AND 2010 FBC W/- 4 RESIDENTIAL CHAPTER 41, SECTION 4101.6.6. a PLUMBING NOTES: a 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE 2010 FLORIDA RESIDENTIAL CODE, PLUMBING AND SECTION R4101- PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT A EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES CW.) AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE O a SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE py DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A �] SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE WW READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. H 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS 0 OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF Z RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. V) 6. ALL POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO 3'-0" BELOW POOL/SPA DECK V ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. S. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. U 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER 4 SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY V2 MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER H A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO U THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC Q WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 MINUTES. [..i 11. JOINTS. AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA W BUILDING CODE, PLUMBING. p 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR a UNION CONNECTION ADJACENT TO THE HEATER. pti 13. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER 2010 FLORIDA BUILDING CODE - 605.21. 14. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. F (SEPARATE PLANS AND PERMIT REQUIRED) ►°�-i 15. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY. Q7� 16. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY. W 5 a O Z r-i A F w4 a� M � Z ti y Q � •O � p r c') `' W Z %>Z o '.,off'•...... . •'�Q��. �j �aM V1 � Vi W � � a�proz a0o � M V rl o a a oz r� 0 E"I U a FL� F C) Z DRAWN BY: MAP CHECKED BY: WJC DATE: 1-20-14 SCALE: AS NOTED JOB NUMBER: 13 - 205 SHEET 3 OF 3