HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSSCANNED
By
S$ h IMP CCU"$v .
.i
H 0 M E '�' PRIDE
Manufactured Ho� ing Installation Instructions
Lock Dou Anchoring System
Wind Zones 2 & 3
File Copy
i A
I -Beam
Anchor &
Stabilizer
ection
NOTE: If one or more of the following conditions exist conta a Registered Professional Engineer.
• Location is within 1,500' of the coastline.
• Pier Height exceeds48".
• Roof eaves exceeds 16".
• Sidewall height exceeds'96".
• Length of home exceeds 76'.
REQUIREMENTS FOR USE
1. The use of the Lock Down Anchoring System requires idewall vertical ties at no greater than 5'4" on center.
2. Centerline anchors to be sized according to the soil torque conditions.
3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor.
4. Sidewall vertical ties can use 4' anchors in soil type 4131
Facing the home Facing the home
LEFT CORNER RIGHT CORNER
5. Homes requiring 4 Lock Down Anchor
assemblies require the longitudinal
and lateral strut on each anchor. All
struts must be installed towards the
center of the home.
Facing the
LEFT COR1
6. Homes requiring 6 Lock Down Anchor
assemblies only require longitudinal
struts on the 4 corner positions. The
two center positions only require a
lateral strut. All struts must be installed
towards the center of the home.
7. The placement of the corner systems should be at a
each comer.
1. H O.M_E____ P_R 1 D E
tudinal
Facing the home Facing the home
CENTER RIGHT CORNER
G
sri. 50?.., V ,
S
a: �(•i4�i�""a.
�+�y`
t"'.9�1
.'y. %� 'w 'j� 5-r .T3"yy,.(�� 1-. Ln
;.4i
rbrlS*'iF" `Mi'. lei�YP: S•�T erN; Yt'�
vertical tie that falls no more than 11' and no less than 5' from the end of the house on
a
NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED:
Wind Zones 2 & 3 with roof pitch 6/12 or less.
• Single or Double section homes 30' to 52 in length -(excluding hitch) 4
• Single or Double section homes greater than 52' to 76' in length (excluding hitch) 6
NOTE: Roof pitches greater than 6/12 will require additional systeres, contact Home Pride, Inc. for assistance.
NOTE: Homes less than 30' — Lock Down System should not be used.
NOTE: Home manufacturers may provide a placement chart for specific models in their installation manual. The manufacturer's placement chart supersedes the
chart below.
ANCHOR ASSEMBLY PLACEMENT
Using 4 Anchor Assemblies Using 6 Anchor Assemblies
- - _"E
B-M
Lock Down Anchor Assembly Comments List Ab
1. Ground Anchor with Strut Attachment Cap
2. Stabilizer7
7T
'
3. Lateral Strut J>
4. Longitudinal Strut
S. Beam Clamp Assembly
62
Lock Down Anchor Assembly Installation Instructions
The Ground Anchor with Strut Attachment Cap will take the place of one perimeter anchor
and align with a sidewall vertical strap. Install this anchor at a slight anile, not to exceed 1
15 degrees. This assembly includes a stabilizer plate that Is installed w th the anchor and
attached with a U-bolt and two nuts. The stabilizer plate should be driven into the ground + p sidaw,ns<.,o
when the anchor is about 2/3 installed. Attach the stabilizer to the anchor shaft using the
U-bolt and nuts then complete the install of the anchor until the strut ttachment cap is
flush to the:ground or slightly recessed into the ground, no more than ". The Strut
Attachment Cap should be installed within Y." or flush to the top of the stabilizer plate.
(See illustration to the right.)
NOTE: State of Florida allows a 2' pilot holes to be drilled to assist anchor installation in extremely hard soil conditions. If this process is used during installation
of the Ground Anchor with,Strut Attachment Cap the soil must be plaIFed back in the pilot hole and compacted at 6" intervals. This process should take place
when the anchor is 8"-10" from fully installed — allowing room for they, soil to be placed back in the pilot hole and properly packed.
HOME .. 2.
Once the ground anchorassembly is fully installed, attach longitudinal and lateral struts according to the diagram under anchor assembly placement (page 1.). The
lateral arm, fasteners are. to be installed tightly (nuts and bolts). The Beam Clamp assembly has two holes for the bolt and nut placement. Depending on the width of
the beam, the corresponding hole should be used that pushes the frorjt of the metal plate as close as possible to the upright of the beam. See the illustration on page
2, #S.
Lateral struts should be installed in line with the center anchor head a0d attached at the top of the I-beam.
Lateral strut angles must fall within 10 degree minimum - 60 degree
Longitudinal Strut
AttochedPalnt
Facing the homeLEFTCORNER
' LAteralstmt
AttachedNnt
sidowAstrap
connadlon
Longitudinal strut angles must fall within 10 degree minimum - 50 degree maximum.
Longitudinal Strut
Attached Point
Fa"cing tho homy RIGHT CORNER
;oral Strut
chod point
.trap
Ion
After the Lock Down Anchor Assemblies have been fully installed andlall.permiter anchors and straps fully installed.and tightened — each strut has 4 self tapping
screws that must be installed as the final step. Predrilled holes are p ovided on the outer strut indicating placement. If the predrilled holes cannot be accessed,
install the screws as close to the predrilled holes as possible - making sure they are tapping Into the inner strut.
The Lock Down Anchoring System should only be used for homes in the state of Florida. This anchoring system is notdesigned, tested or approved for use in any
other state.
Contact Home Pride Inc. 276-46"502 or at contactus0hoanchors.corh for any questions concering this product.
Legacy Engineering listing # 113
Notes:
PRODUCT WARRANTY
Home Pride warrants its Lock Down, Anchor System (HP LDS) against d facts in orkmanship and material at the site of its initial installation. The HP LDS is specifically
designed and approved for use in the State of Florida. This product i7not approwved for use and should not be used outside the State of Florida. This product must
not be reused or reinstalled at any other location. If used in violation of this Warranty or not installed in accordance with installation instructions, all written and
implied warranties are void and disclaimed. HP LDS products which arelI�found to have defects will be replaced or repaired at Home Pride's option. This Express Warranty
is limited to replacement of product only and does not cover any IaboY or installations costs. When the product is replaced, all Warranty rights are extinguished. This
t Warranty is only to the benefiof the original purchaser and is nottrapsferable.
There -are no other warranties (express or implied) whatsoever which'apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home
Pride disclaims any and all other Implied warranties, including (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose
to the extent allowed bylaw and any implied warranty that exists desl ilte this disclaimer is limited to a period of one (1) year from the effective date of this Warranty.
These limitations shall be enforceable to the extent permitted by law.
HP LDS products which are examined and are found not to be defectivR will be returned to user and all costs associated with examination of the anchor product will be
incurred by the user. The user is responsible for all maintenance of the HP LDS product including regular monitoring of stability and integrity of HP LDS products.
For a warranty claim, contactyour distributor or Home Pride Inc. at 1 100 Industrial Park Road, Bristol, Virginia, 24202.
3, H 0 M E_ E