Loading...
HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSL ' - SCANNED By st brlp P60fi& HOME PRIDE Manufactured H Lock Di ,ng Installation Instructions Anchoring System Zones 2 & 3 ��m Anchor & Stabilizer I -Beam Connection I 1 00 o 0 O I NOTE: If one or more of the following conditions exist contacts Registered Professional Engineer. • Location is within 1,500' of the coastline. • Pier Height exceeds 48". • Roof eaves exceeds 16". • Sidewall height exceeds 96". I • Length of home, exceeds 76. I REQUIREMENTS FOR USE 1. The use of the Lock Down Anchoring System requires sidewall vertical ties at no greater than 5'4" on center. 2. Centerline anchors to be sized according to the soil torque conditions. 3. Sidewall anchor loads in excess of 4000 pounds requires a 5' anchor. 4. Sidewall vertical ties can use 4' anchors in soil type 48. the home 5. Homes requiring 4 Lock Down Anchor assemblies require the longitudinal and lateral strut on each anchor. All struts must be installed towards the center of the home. =acing the home LEFT CORNER 6. Homes requiring 6 Lock Down Anchor assemblies only require longitudinal struts on the 4 corner positions. The two center -positions only require a lateral strut. All struts -must be'installed towards the center of the home. Lateral/Longitudinal Strut Facing the home RIGHT CORNER Facing the home Facing the home CENTER RIGHT CORNER 7. The placement of the corner systems should be at a sidewall vertical tie that falls no more than 11' and no less than 5' from the end of the house on each corner. I 1. HOME $ PRIDE NUMBER OF LOCK DOWN ANCHOR ASSEMBLIES NEEDED: Wind Zones 2 & 3 with roof pitch 6/12 or less. • Single or Double section homes 30'to 52 in length -(excluding hitch) 4 • Single or Double section homes greater than 52' to 76'lin length (excluding hitch) 6 I NOTE: Roof pitches greater than 6/12 will require additional systems, contact Home Pride, Inc. for assistance. NOTE: Homes less than 30' — Lock Down System should not be Ised. NOTE: Home manufacturers may provide a placement chart for, specific models in their installation manual. The manufacturer's placement chart supersedes the chart below. ANCHOR ASSEMBLY PLACEMENT Using 4 Anchor Assemblies �1 P11 ril►J ISII � � [AI m! 1* Imo- 11m 00 i MR MR -. Lock Down Anchor_ Assembly Components List 1. Ground Anchor with Strut Attachment Cap 2. Stabilizer 3. Lateral Strut 4. Longitudinal Strut S. Beam Clamp Assembly Lock Down Anchor Assembly Installation Instructions The Ground Anchor with Strut Attachment Cap will take the and align with a sidewall vertical strap. Install this anchor at 15 degrees. This assembly includes a stabilizer plate that is i attached with a U=bolt and two nuts. The stabilizer plate she when the anchor is about 2/3 Installed. Attach the stabilizer U-bolt and nuts then complete the install of the anchor untll flush to the ground or slightly recessed into the ground, no r Attachment Cap should be installed within Y." or flush to the S ( ee illustration to the right.) I i i NOTE: State of Florida allows a 2' pilot holes to be drilled to assist anchor installation in extremely hard soil conditions. If this process is used during installation Of the Ground Anchorwith Strut Attachment Cap the soil must be placed back in the pilot hole and compacted at 6" intervals. This process should take place when the anchor is 8"-10" from fully installed — allowing room for the soil to be placed back in the pilot hole and properly packed. I i slight angle, not to exceed stalled with the anchor and Id be driven into the ground the anchor shaft using the N N e OWN"G'a �i ii"is",alb uN HOME PRIDE 2. Once the ground anchor assembly is fully installed, attach longitudinal and lateral struts according to the diagram under anchor assembly placement (page 1.). The lateral arm fasteners are to be installed tightly (nuts and bolts). Tije Beam Clamp assembly has two holes for the bolt and nutplacement. Depending on the width of the beam, the corresponding hole should be used that pushes the front of the metal plate -as close as possible to the upright of the beam. See the illustration on page 2, #5. Lateral struts should be installed in line with the center anchor Lateral strut angles must fall within 10 degree minimum - 60 Facing and attached at the top of the I-beam. maximum. Longitudinal strut angles must fall within 10 degree minimum - 50 degree maximum. LongkudinalStrut. Attached Point . . r LatoralStrut Attaahad Writ Eidawall'Snap sidewall Strap connoctloe Connection After the Lock Down Anchor Assemblies have been fully installed and all permtter anchors and straps fully installed.and tightened — each strut has 4 self tapping screws that must be installed as the final step. Predrilled holes are provided on the outer strut indicating placement. If the predrilled holes cannot be accessed, install the screws as close to the predrilled holes as possible - making sure they are tapping Into the inner strut. The Lock Down Anchoring System should only be used for homes in the state of Florida. This anchoring system is not designed, tested or approved for use in any other state. Contact Home Pride Inc. 276-466-0502 or Legacy Engineering listing # 113 Notes: for any questions concering this product. PRODUCT WARRANTY Home Pride warrants -its Lock Down. Anchor System (HP LDS) against defects in workmanship and material at the site of its initlaI installation. The HP LDS is specifically designed and approved for use in -the State of Florida. This product is not approved for use and should not be used outside the State of Florida. This product must not be reused or reinstalled at any other -location. If used in I6lation of this Warranty or not installed in accordance with Installation instructions, all written and implied warranties.are void and disclaimed. HP LDS products which are found to have defects will be replaced or repaired at Home Pride's option. This Express Warranty Is limited to,replacement of product only. and does not cover any labor or installations costs. When the product is replaced, all Warranty rights are extinguished. This Warranty is only to the benefit of the original purchaser and is not transferable. There are no other warranties (express or implied) whatsoeverIwhich apply to the HP LDS product or to items that are functionally part of the HP LDS product. Home Pride disclaims any and all other implied warranties, including (but not limited to) warranties of habitability, workmanship, materials and fitness for a particular purpose to the extent allowed by law and any Implied warranty that exists despite this disclaimer is limited to a period of one (1) year from the effective date of this Warranty. These limitations shall be enforceable to the extent permitted by law. - HP LDS products which are examined and are found not to be defective will be returned to user and all costs associated with examination of the anchor product will be incurred by the user. The user is responsible for all maintenance of the HP LDS product including regular monitoring.of stability and integrity of HP LDS products. For a warranty claim, contact your distributor or Home Pride Inc. at 15100Industrial Park Road, Bristol, Virginia, 24202. 3. H0ME`''PRID.E