Loading...
HomeMy WebLinkAboutFIBERGLASS STEP TESTINGINDUSTR &MALWIC, March, 24 2010 Home Pride inc. 21S8 Travelite Dr. Bristol, va 242o2 Phone: (276) 642-0271 Fax: (276) 642-0284 Report No. — LO-FJ90125 Attention: Mr. Charles Hughes Subject: Fiberglass Step Testing Item Description: Home Pride model: a513lS, 3500S3,3S1290, 350180, I350055, 351327, 350063, 350062, 351324, 350061, 350046, 350047, 351300 Method of identification: Home Pride peal and stick data sheet. Test Mr. Hughes, we performed dimensional testing on the fiberglass stairs that you manufacturer to verify the compliance with state and federal codes for stairways. This testing consisted of measuring the overall height, -width, length, length of rise, and length of run. All stairs tested had to meet a predetermined test procedure. This test procedure referenced the minimum'stair width to be not less than thirty six (36) Inches. The maximum rise of seven and three quarter (73/4) Inches with no more than three -eights (%) inch variations. The minirnum run being no less than nine (9) inches with no more than three -eights N variation. The following chart shows the model and data collected during testing. 510 i WJL. ONG ROAD MEMPHIs, TN 38134X%QM992 FAx 901 373-5825 Model:; 350180 'Helght:.35" Width: 38" .Depth: 38" Item - -Requirement Results Status Height I N/A 35.1875" Acceptable Width (min) i 36" 38.18750 Acceptable Depth I N/A. 38.7500" Acceptable Rise (max) I .7.7500" 7.3Z50" Acceptable Rlse (variation) less than 0.37SO"• 0.2SO0" Acceptable Run (min) I 9" 11.3125" Acceptable - Run, (variation) less -than 0.37SO" -0.0625" Acceptable As referenced to the previous data; all models had acceptable results. No Edge Radius was reported due to the fact that all tread depths were greater than eleven (11) Inches. These results are based on requirements of the International Residential Code, Florida Residential Building Code. These are the two t2) codes directly resourced but not limited to only these two (2). 1 If we can answer any questions call. Respectfully Submitted, A erlcan n strial Testing (01//w Will Jackson i Assistant Manager i this report or be any further assistance feel free to I 5 10 1 WILFONG RoAo MEA4PFNS, TN 38134 901-373-6992 FAx 901-373-5825