Loading...
HomeMy WebLinkAboutSEAWALL PLAN5/8"ALLTHREAD W/ NUTS AND WASHERS (HDG) RECESS CUT 8"X8" WAILER 2"X6"TOP V TOP OF PROPOSED WALL 3.3± NAVE) F1 8"X8"WAILER CJ 2"x6" DECKING W/ 3" SS FASTENER 8"X8" WAILER APPROX. MHW ELEV. -0.7± NAVD MUCK 13'± MATCH EXISTING GRADE GRADE 3" BELOW TOP OF WALL FOR SOD. / i i i i i i �-4"X6"WAILER i TOP OF EXISTING WALL EL 2.3± L /EXISTING WALL PUNCH THROUGH/CUT AS NEED FOR NEW DEADMEN/ANCHOR AS SPECIFIED 5/8" ALL TREAD HDG W/ 6"'L BEND' I (~EXISTING WOOD WALL TO REMAIN I I I I I 10•+ Section A -A 4"X6" WAILER Plan View PSI F ER MESH CONCRETE 4"X12 (TYP) 3000 PSI FIBFR MESH CONCRETE _ 24'k24 X12" TYP) 518" ALL TREAD HDG W/ 6" 'L BEND' 4'-6" MIN. 8" LAP NC FOR WAILER WAILER 5/8"ALLTHREAD HE W/ HDG NUTS AND RECESS CUT 8 X8" A7 MIN. 8" LAP NOTCH FOR WAILER A--o*1 Z m I TIE INTO ADJACENT SEAWALL L NE EX I \ \ I \ I \ I \ BLOCK 23 LOT D Ilm PROJECT DESCRIPTION INSTALL VINYL WALL WITH WOOD CAP IN FRONT OF EXISTING WALL. WALL LENGTH APPROX. 225 LF WITH RETURN AT EITHER END. NOTES: 1. ALL LUMBER TO BE C.C.A. 0.60 MARINE GRADE (MIN.) 2. ALL FASTENERS TO BE HOT DIPPED GALVINIZED UNLESS OTHERWISE NOTED. 3. 14' VANGUARD STANDARD VINYL PANELS (MANUFACTURE SPECIFICATIONS ATTACHED) 4. GRADE AND SOD SITE UPON COMPLETION. 5. ALL ELEVATIONS AS SHOWN ARE BASED ON NAVD(88). 6. CONTRACTOR TO CONTACT ENGINEER PRIOR TO COMMENCEMENT FOR INSPECTIONS. BLOCK 23 LOT C i EXISTING BOAT LIFT INDIAN RIVER SCANAEu Illy of DF COURT_ North Graphic Scale ItiO3 ro5r3 ST. LUCTIF COLT TY Ri; "rVISION REVI -'R FOR COa L CE REVIEW'E Y DATE 4 Z�l PLANS AND PERMIT MU T BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT BLOCK 23 MAY BE NECESSARY IN ORDER TO LOT F COMPW WITH A66 ApPWCAtLS 0000, "'ONGFALED FAS i ENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF: RECORD r- 0.330" Copy 9.01, SHAPE Z STIFFNESS 334I LB-IN2/FT THICKNESS 0.330 ALLOWABLE MOMENT 5,292 -: (IN) (M)FT-LB/FT WIDTH I8 MODULUS OF ELASTICITY (E) ' 380,000 (IN) PSI DEPTH 900 ULTIMATE TENSILE STRESS 6,SQ0 (IN) PA SECTION MODULUS 4 I9.54 CREEP LIMITED STRESS (n IN 3/FT PSI MOMENT OF INERTIA 87,93 COLOR 119Lf�TGI{�)' (q 1n a/ft @R 1 , 'Ihe valwKshown 3n this damnent are aeemgee and mal-rvry.Nn wumotier uPvoykfml are merle u bu Ncwllehlllty ut Vu�guud VInl95euwall Ynk airy pan3<uFar appliezdon <" rcs"hc"LtaLmd IhI,.1 1 MARK REVISION SMB CHECKED 11 SBM SCALE 11 AS NOTED DATE I BY JDATE 11ne Ann i�r THE DRAWINGS ARE THE PROPERTY OF THE ENGINEER. WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. COPY OR USE FOR OTHER PROJECTS IS PERMITTED ONLY By WRITTEN CONTRACT WITH THE ENGINEER. UNAUTHORIZED USE WILL BE PROSECUTED PURSUANT TO THE COPYRIGHT LAWS. -- KNIGHT, WGUIRE & ASSOCIATES, INC. CONSULTING ENGINEERS AND PLANNERS 4ci 80 ROYAL PALM POINTE, SUITE 401 VERO BEACH, FL 32960 PHONE: (772) 569-5505 FAX: (772) 569-1455 E-MAIL: Civil@KnightMcGuire.com CERTIFICATE OF AUTHORIZATION NUMBER - 00006335 Bacci Residence St. Lucie County, Florida 34949 Seawall Plan DATSHEET � ✓r Scott B. McGTYire, P.E. David S. Knight, P.E. O� 1 I Fl. Reg No. 39573 Reg No. 41060 1