Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES�lofida , , . Product Approval r i5 USER: Public User I Product Approval Menu > Product or Anpllcation Search > Apollcation List > Applicatioi.Detail Fl 10674-1213 Application Type evlsion Code Version 2017 Application Status Approved Comments Archived J .Product Manufaaurer I Owens, Corning;_ Address/Phone/Email One Owens Coming Parkway Toledo, OH 43659 (740).404-7829 greg.keeler@owenscorning.com Authorized Signature i Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category,, Roofng,, Subcategory, Asphalt -Shingles_: Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer.or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sectionsfrom the Code. FL10674 R13 COI 2017 01 COI Nieminen,odf Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXOwtDgtBNbEY5V%2boQT%2b6w7ahReglCQBucR6ixEBFhs7tvJgZew%3d%3d 3/30/2n18 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 . Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Coming Asphalt Roofing. 3-tab, 4-tab, 5-tab, laminated, starter and hip &. ridge shingles Shingles and !Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-R13.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert]. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL16674 R13 AE 2017 10 FINAL ER OC ASPHALT SHINGLES FL10674-R13:pdf Created by Independent Third Party: Yes Contact Us;: 2601 Blair Stone Road, TallahasseeFL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privaw Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the of o by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October, 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., jplease click here . Product Approval Accepts: 979199 i C:C60l4 Gard. . https://www.floridabuilding.org/prlpr_app dtl.aspx?param=WGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQBucR6ixEBFhs7tvJgZew%3d%3d NITY I ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 EXTERIOR RESEARCH & DESIGN, LLC. Certificate ofAuthorkation #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report 037940.02.12-R8 FL10674-1113 Date of Issuance:02/06/2012 Revision 8: • 10/09/2017 SCOPE: This Evaluation Report is issued under Rule!61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance' with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1S07.2.7.1 / R90S.2.6.1. CONTINUED COMPLIANCE, This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative tolupdated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of they Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be, provided to the user by the manufacturer or its -distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through B. i Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was Authorized by Robert Nieminen, P.E. on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing'or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, norlwill acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose.. F�o -.f I RINITYERD ROOFING SYSTEMS EVALUATION: - 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections[ofthe 6a' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to 'the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property! . . Standard Year 1507.2.5,-R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference } Date UL LLC (CER9626) Physicals,'& Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals(& Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263. 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 ' 02/10/2014 UL LLC (TST9628) PhysicaliProperties Classification letter 02/13/2014 UL LLC (TST9628) Physicali Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality,Control Service Confirmation Exp. 05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireTM' are fiberglass reinforced,•5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinitionm Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition' Oakridge, Oakridge' and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge; WeatherGuarde HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgel Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip. Shingle, -Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6T" EDITION (2017) FBC'NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 . -TRINITY ER® 5:4 Wind Classification: SA.1 All Owens' Corning -asphalt shingles noted herein are Classified in accordance with FBC Tables 1S07.2.7.1 and R905.2.6.1 to ASTM D3161,.Class F and/or ASTM D71S8, Class H, indicating the shingles are acceptable for use in all wind zones up. to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Veit =194 mph). Refer to Section 6 for installation.requirements to meet this wind rating. 5.4.3 Classification by ASTM D7258 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design. professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6_1 Underlavment: 6.1.1 'Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1S07.2.3.1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. ➢ DevonshireTM shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. - - Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 2507.2.6 or R90S.2:5. Staples are not permitted. 6.2.4 Where -the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck I Self-adrered r weatherloeke undedayrnent Dnp .' pt�edge edge s + Nar1s located from eave Install first Self•searing adhesive Starter Slip positioned along cave shingle with . 6'removed Starter Strip ihingle overhangs eaves and rake's'A -i'i ` — trait w eadulan�nt OriP� uT4loened from eave SiihseaGag adhostva positkned obng e0ve darter p Pkw overhangssaves and rakes 11 -V Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate ofAuthorkaUon #9503 e.EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 ._.. , TRINITY I ERD. 6.2.6 Minimum Nailing —Classic®& Supreme: 6 Mormai Mans,ard or Area pore Wind Areas High Wind desvenssy Amos pare visntos normnfas Arsas 4lentos frrq{tes I. IA) i� z• ie z• r �r tr S"Esposure I Exposieidn i 2.7 Minimum Nailing — Berkshire®. Standan Normal Mansard or Area pars Wind; Areas High' Wind desvivnes y Aria, parm WWWas normatos Areas ylsoos fusrtas. 6 5i8" Fapowra ileldn Eagio' sealentwip La 16a doseliador a W s Wl owl !rn 6 Mansard or Steep Slope Fastening Pattern 'attern Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-118 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 6.2.8. Minimum Nailing —Devonshire"': 1" I• �_ •i•- i �t 5118' exposure Exposiel6n de 5 -5/8 pulg ji a I 7" to i Sealant location Ubicad6n del seliador �j�N1N I ERD 47 Nails T SW _ to Ten f S ots of As halt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration Designer Color Collection: "all Fastening,Paftm . SlrttiNiftefastirdllp.aiei wlCar Na4nN�. ?•V•��•"•MlbMrl i..:.t'Rl'�A3Y^..O': ..UwwC'�S"a.�d3'-ta'"• Standard Fastening Pattern 6-Nall Fastening Pattern, smtt.Na�l®rubullpatra x7Qflt. 'NA''jypinal. 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 ' �anfaatenlllamewhm Nap.nylbf ill 1T f2" Owl ' E 01 Foie t"fpob 6fAapmli Rnnprtg Wmant Mansard or Steep Slope Fastening Pattern Exterior Research and Design, I.I.C. Certificate ofAuthoriration #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Owens Coming Asphalt Roof Shingles Evaluation Report 037940.02.12-118 F110674-1113 Revision 8:10/09/2017 Page 5 of 8 i 6.2.1 Minimum Nailing —TruDefinitign■Oakridge°,Oakridge®: d Nall Pattern Esquemafcon Q;clagos. MON 55/87.apaswe.. -Nails; 5 W Exposure:.. Exposk7eitde&5/Sppfg. C(avos Exposlapnde6&/8pu(g. Standard Fastening Pattern \J I jilNIlY I ERD .6 Nall Pkem Esguema eon6,davos: r r. • I�— � —aI k— 1z" —nj; 55/8" Exposure, Fxposlgldnde'S5/8pvlg:. is Nww Nails 6 5!8' 'sate Cdavos 6aiposiaBn de 5.5L8�Wg•. 6-Nail Fastening Pattern Eastming for 8lopes Giea1erTMd21:12 . WnNa48 tasteNaJ �nawldM t4x,1YNe+r ' f�ct',Spab etAfyhax RooMe Cunertt Mansard or Steep Slope Fastening Pattern 6.2.1. Minimum Nailing—WeatherGuard®HP: . Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 CertlflcateofAuthorkation#9503 6T" EDITION (2017).FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 i TRINITY I ERD 6.3 Hip & Ridge Shingles: 6.3.1- Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge7N1 Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to -Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshiree Hip & Ridge and High Ridge: FIi3,:4. T. �— PlevetlngYARd D'¢edan 'A 4 A i I I I <P I I I �e 6.3.4 Minimum Nailing—WeatherGuard® HP Hip and Ridge: Fig: C Hip.& Ridge S..hingle.rastening ToaView - Nal!$ Naps . T' S "Sum 1 I 17' Exterior Research and Design, U.C. Evaluation Report 037940.02.12-RB Certiflcate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 i I 6.3.5 Minimum Nailing - ProEdge Hip;& Ridge Shingles: Preva0ing Wind Direction sealant strip • --'~ 8° EgrMm 6.3.6 Minimum Nailing — DuraRi Note: The drawings below published installation instr CoueTFepand Flfitie�fA With Roof Cemeet C)o - \l-rPJnrrlERD Standard Fastening Pattern 12. 1 $"AIM 8°Exposure 1 1 Hip & Ridge Shingles: ain to minimum, as -tested attachment requirements. Refer to Owens Corning ins for their minimum requirements. TopYlffw Yue m ptvr I- vhbsuperror I- Can sib I I• call � � zl�m UL IN -I. �12 7. LABELING: . 7.1 Labeling shall be in accordance with the requirements the Accredited • Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with -one of the required classifications detailed in FBC Table 1S07.23.1 / R90S.2.6.1. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.. 9. MANUFACTURING PLANTS: i Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate o/Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8