Application Type Revision ST. LUCIE COUNTY BUILDING DIVISION
UNMe.i®R, 20:.7: REVIEWED FOR COMPLIANCE
Application Status Approved REVIE D B
DATE -
PLANS AND PERMI MUST BE K ON JOB
Comments �' SITE OR' NO INSPECTION(S) WILL BE MADE
Archived
I
i
Pro uct aiacturer ! xri, .uii �N1at ale Group; LLG
Ad tees/Phone/Email PO Box 70
Rutherford, N3 07070
(800) 516-1485
david.ruiz@trlbuiltmg.com
Authorized Signature ! David Ru12
david.ruiz"builtr PLANS AND ALL PROPOSED WOF
i ARE SUBJECT TO ANY CORRECTIONS
Technical Representative David Ruiz REQUIRED BY FIELD INSPECTORS THAT
Address/Phone/Email I 250 Route 17 NortflAY� pBE NECESSARY IN ORDER TO
East Rutherford, N 073 LY WITH ALL APPLICABLE CODES
(201) 842-2449
david.ruiz@tribuiltmatertaisgroup.com
Quality Assurance Representative
Address/Phone/Emall
aCe"I WAN-
w R' - — �-.
Compliance Method
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rlch.schurman@allledbuilding.com
Roo
ed�8itu�nen.Rcof 5,y'a�t'e�
Evaluation Report from a Florida Registered Architect or i
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida Ucense
PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By Sohn W. Knezevlch, PE
Validation Checklist - Hardcopy Received
Certificate of Independence df
B FL16Q27 R2 C0I 2017 01 COI Nleminen.o
J FILE Cop• CONCEALED FASTENERS OR ATTACHMENTS
ARE THE. RESPONSIBILfiY OF THE
CONTRACTOR OR RECORD
Referenced Standard and'. = (of Standard) IStandard
ASTM D6163
j ASTM D6164
i FM 4470
FM 4474
Equivalence of Product Standards i
Certified By 1
I
Sections from the Code
I
II
Product Approval Method Method 1 Option D
Date Submitted
09/25/2017
Date Validated
09/30/2017
Date Pending FBC Approval
10/08/2017
Date Approved
12/12/2017
FL * I Model, Number or Name I Description
Yes
200
201
z01
201
201
16027.1 TRI-BUILT Modified Bitumen Roof SBS and APP modified bitumen roof systems
Systems
Limits of Use Installation Instructions
Approved for use In HVHZ: No I FL160V R2 II 17 02 FINAL Al ER TRI
Approved for use outside HVHZ: Yes BUILT MODBIT FL16027-R2.odf
Impact Resistant: N/A Verified By: Robert Nleminen PE-59166
Design Pressures +N/A/-622.5 Created by Independent Third Party: Yes
Otheri 1.) The Design Pressure noted In this application refers Evaluation Reports
to one system. Refer to ER Appendix for all systems and max, FL16027 R2 AE 2017 09 FINAL ER TRI
design pressures. 2.) Refer to ER Section 5 for Limits of Use: BUILT MODBIT FL16027-R2.odf
Created by Independent Third Party: Yes
&grit ltiftlxl
Contact Us :: 2601 Blair stone eRoad, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/REO employer. Copyright 2007-2023 State of Florida.:: Privacy Statement :: Accessibility Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlc•records request,
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850AS7.1395. sPt
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter455, F.S. must provide the Department with an emal
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not Me
address, please provide the Department wfth an email address which can be made available to the public. To determine If you are a licensee un
please click h2L.
Product Approval Accepts:
.Ct'�dit Cafd. ,
I
{
�\4 TR1NiTY = ERD
Table :
Deck
Application
Two
Description
Pala
IA-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet Banded Insulation, Bonded Roof Cover
4
.IA-2
Wood
New, Reroof (Fearer Or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof [over
5
18
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
iC
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded•Roof Cover
6'
1D
Wood
New, Reroof (fear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
1E-1
Wood
New or Reroof (Tear -Off)
E
Non -insulated, Mich. Attached Base Sheet Bonded Roof Cover
7
1E-2
Wood
New, Remof (fear -Off) or Recover
E
Non -insulated, Mech. Attached Base Sheet Bonded Roof Cover
8
IF
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
8
2A
Steel or Structural concrete
New, Reroof (Year -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
28
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Rerc of (Tear -Of) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Str=Wral concrete
New or Reroof (Tear -Olaf)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
36
Structural concrete
New or Reroof (Tear -OM
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
15-16
4B
LWIC
New or Reroof (fear -Off)
A-2
Meth. Attached Anchor Sheet Bonded Insulation, Bonded Roof Cover
16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
SB
CWF - - - - -
New, Reroof (fear -Of) or Recover
A-2
Mech. Attached Anchor Sheet Bonded Insulation, Bonded Roof Cover
21
SC
CWF
New, Reroof (tear -Off or Recover-- -- -
_ _B-
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
51)
CWF
New, Reroof (tear -Off) or Recover
C
Medi Attached dnsutatlon,.8onded Roof Cover
22
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -insulated, Mech. Attached Base Sheet Bonded Roof Cover — - _ _ _
22
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
— 23-- - -
6B
Gypsum,
New, Reroof (fear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
} 6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
24
613
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -insulated, Mech. Attached Base Sheet Bonded Roof Cover
24
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
25-26
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet Bonded Roof Cover
26
The foRawina notes amply to the systems outlined herein;
1. Tlie roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement
➢ Wood: Minimum 0.754ndh penetration.
D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 14nch embedment into pilot hole in accordance with fastener manufacturees published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perldte, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, LLC d/b/a TrinityjERD Evaluation Report A42970.10.tZ-R2 for Ff16027-RZ
,r Certificate of Authorization 49503 6'"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:09/25/2017
Prepared by: Robert Nieminen, PE-59166 TR14UILT Modified Bitumen Roof Systems, (B00) 316-148S Appendix 1, Page i of 26
TRIN TY F�a
Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D {mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM toss Prevention Data Sheet 1-29 (January 2016).
Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
D HA (HA): Full coverage at 25-30lbs/square.
Y Dow INSTA ST1K Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to I -inch wide ribbons,l2-inch o.c.
_•la Mllfennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons,l2-inch o.c.
Y OMG OlyBond SOD (06500): Continuous 0.7S to 1-inch wide ribbons, 12-inch o.c. (PaoeCart or SpotShot). Nate: Oly&wd Green maybe used where 01y8ond SW is referenced.
D OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
t a iCP Adhesive &Sealants CR-20: Continuous 2.5-3.5•inch wide ribbons, 12-inch o.c
i D Note: When multiple layers(s) of Insulation and%r coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from foyer -to -layer a distance ofone-haljthe ribbon spacing.
' D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-hay'the specified ribbons spacing.
Unless otherwise noted, all Insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MOP) limitations. in no case shall these values be used to 'Inc ease' the MOP listings in the tables; rather V MOP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a dropdn for the equivalent thicker material listed in the table:
D Millennium One Step Foamable Adhesive (M-OSFA): MOP -157.5 psf (Min. 0.5-inch thick)
f 0 OMG OlyBond SOO (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
D OMG OlyBond 500 (0B500): MDP -187.5 psf "(Min.0.5-Inch thick iso 95+G1.)
OMG OlyBond SOO (08500): MOP -315.0 psf (Min. 0.5-Inch thick ENRGV 3)
D OMG OlyBond SOD (06500)i - - --- - _ _ MDP -487.5 psf (Min. O.S-inch thick ACFoam 11)
D ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. L04nch thick)
8. Bonded potyisokyanurate Insulation boards.shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria Commonly used methods are ANSi/SPRI WDl, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-291January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawn{ resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be In accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shag be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority. Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TA5124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shag be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point L
Ertterho- Research and Design. I.I.C. d/b/a Trin1ty1ERO Evaluation Report A42970.10.1.2-R2 for FL16027-R2
Certificate of Authorization ft9503 6h" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (Bt10) 516-1465 Appendix 1, Page 2 of 26
TRINRYiEkD
15. Unless noted, refer to the following references for bonded base, ply or cap sheet applications.
Oil.
Reference
Laver
Material
Application
BP -AA
Base Ply
FBC Approved ASTM 04601, Type 11
HAatzo4olbs/square
Ply
FBC Approved ASTM 02178, Type IV or VI
(Base and Ply sheets, Asphalt -Applied)
SOS -AA
Cap Ply
TdBuiltSBSGranular
HA at 20-40 lbs/square
(SBS, Asphalt -Applied)
SBS-TA
Cap Pb/
TriBuilt SBS Granular.
Torch -Applied
(SOS, Torch -Applied)
SOS -SA
Owe Ply
TriBuilt SA SBS Base
%f-Adhering
Cap Ply
TriBuilt SA SB5 Cap
1[58S, Self-AdherIng)
APP TA
I Base Ply or Ply
TriBuilt APP Smooth
Torch Applied
Cap Ply
TriBuilt APP Smooth, TriBuilt APP Granular
{APP, Torch -Applied)
APP-SA
Cap Ply
TriBuilt SA APP Cap
n
Self-AdherIg
(APP,Self-Adhering)
16. Vipor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The fesserofthe MOP listings below vs. those In Table 3A
Option #
pritner
Vapor Barrier
Vapor
Insulation Adhesive
MDP,
Type
Attach
VB-1.
ASTM D41
TriBulit SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-6D.0
VB-2.
ASTM D41
TriBuilt SA SIBS Up
Self -Adhering
Insta-Stik 12-Inch o.c.
-75.0
VB-3.
ASTM D41
TriBulit SA SBS Cap
Self -Adhering
Millennium One Step Foarnable Adhesive. 12-inch c.c.
-157.5
VBA
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
CR-20, 12-Inch o.c.
-270.0
VB-5.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
I
Millennium One Step Foarnable Adhesive, Millennium PG-1 Pump Grade
Adhesive, Olygond 500 or CR-20,22-Inch o.c.
-290.0
17. Wns; Deck shall be fieWprimed with PGIOO prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
is. MOP" =Maximum Design Pressure Is the result of testing for wind load resistance based an allowable wind loads. Refer to:FI3C 1609 for determination of design wind loads.
Exterior Research and Design, LL.C. dib/2 Trinity I ERD Evaluation Report A42970.10.12-RZ for EL16027-RZ
Certificate of Authorization 89503 6' EDITION (2017) FBC NON-WHZ EVALUATION Revision 2:09/25/2017
Prepared by: Robert ITterninen, PE-59166 'FR14UILT modified Bitumen Roof Systems, (800) S16-1485 Appendix 1, Page 3 of 26