HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGsGANNED,-
Business
&'Professional '-a e.
#P aoPo�P,h�P�G��d'
BCIS Home Log In I User Registration Hot Topics Submit Surcharge 1 Stats & Facts
b
a
�`Product Approval
d Tir-1 pr Yi USER: Public User
,JI
Publications i FBC Staff I BCIS Site Map I Links i Search i
Product Approval Menu > Product or Application Search > Application List > Appli I Detail
FL # FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
i
Comments 18/2017v. date reapply 08/21/17
Archived C1
RECEIVED
MAR 3 0 2018
ST. Lucie County, Permitting
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yah
coov
FILE
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method _ Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
G Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report I
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
Product Approval Method Method I Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (116)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No i
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.,
17022.2
2 - "SV Crimp" i(116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in
ALUM ssr.odf
this report and applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's (installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
the Installation method listed in this report and applicable
seam 24oa ssr.pdf
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.pdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use: Install the assembly in compliance with
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
the Installation method listed In this report and applicable
ALUMINUM ssr.odf
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.5 15 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf .
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5. 1.0 NAILSTRIP ssr.odf
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.6
6 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A i
Created by Independent Third Party: Yes
Other: Refer to evaluation report forconditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions. i
17022.7
7 - "1.5 in. Nail Strip" (R5)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" I (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr,pdf
limitations of use. Install the assembly Incompliance with
the installation method listed In this report and applicable
Created by Independent Third Party: Yes
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.9
9 - " PBR MAX" (115)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use ll
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr'odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in Compliance with
Evaluation Reports
FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.27S
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
M 0
Credit. Card
Safe
Palm City, FL 34990
1
Compliant with Florida Building Code,2017 (6th ed.), .
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications 1
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0'.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9, x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener '2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads.
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE* ._
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16".o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
! 12" o.c.
12" o.c.
12" o.c.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 590-06 & 1897-041 Test Report 1015893.01-450-18 05/02/14
Test- Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02450-18 ' 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1� *Design pressure margin of safety 2.1
---- :411
�rttt..:
o. ►soyy--,,,
Locke Bowden, P.E. does not have, not will acquire a financial int Vq �>i otg gymO%facturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by a& coinparNorribbilfatturer, or distributing
report.
products under this
•,, . ►ONA4 ti
i
FL17022.1 5V Ci___,ip (26GA Steel), 24" Wide Roof Ft _'il - Details
Limitations:
1:.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
•3�,,Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Lngineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
i
Panel
Overlap
/— Fasteners - —
4
9 x 1-112" Min. or
#10 x acing Min. psign r ss for Row
Spacing and Design Pressures
Hex Washer Head Wood Screws
i
Deck:
15/32" or greater Plywood, or
Wood plank
Nominal 12"
O.C.
24
1r
OPTIORIAL 57RIAMOM
Panel Profile
Nominal 12"
(� O.C. �l
5-V Crimp Roof Panel
Fasten
9 x -1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel.Width
Refer to Table "A" for Spacing Along Panel
Length
Deck-15/32" or greater
Plywood, or
-Wood plank