Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGr" SCANNED lit ip • �. Mh'Id 9, K BCIS Home Log In User Registration 1 Hot Topics Submit Surcharge i Stats & Facts Publications FBC Staff BCIS Site Map Links Search Florida CP USER: Public APproval er "�y; �c.,:�.�1 RECEIVED Product Approval Menu > Product or Aoplication Search > Application List > Application Detail MAR 3 0 2018 FL # � FL17022-R7 Application Type i Revision ST. LuCle County, Permitting Code Version ' 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricato Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 FILE C011v flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN ' the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. CJ Validation Checklist - Hardcopy Received i Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # Model, Number or Name 17022.1 1 - "5V Crimp" (116), Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly In compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. Description 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in ALUM ssr.odf this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. ' 17022.4 14 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this,report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 1 15 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No - ' Design Pressure: +N/A/ -Table A Other: Refer to evaluation report, for conditions and limitations of use. Install the assembly in compliance with 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 117 II FL 17022.3 1.5 MECHANICAL seam 24oa ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 24ga ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM 1LUMINUM ssr.pdf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf Created bj Independent Third Party: Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.6 16 - "1 In. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's !installation instructions. I . 17022.7 7 - "1.5 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed In this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" ( Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes i Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail StriD 26GA ssr.odf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.odf Verified By: Locke Bowden, P.E. 49704 Created. by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 050-457-1624 The State'of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: PW�®E M Credit Card . Safe' Palm City, FL 34990 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec.1507.4.2 Yield strength: 0.032 Aluminum Min.; Attached to min.15/32" plywood or Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.) Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #9 x 1-1/2" Hex-Washer.Head wood screw* to penetrate 3/16" min. thru deck or 5/8" min embedment into wood plank. (*or of sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec:1507. Install Details: Table A Allowable Loads METHOD 1 DESIGN PRESSURE* -168.5 PSF ROW SPACING 10" O.C. FASTENER SPACING (ALONG ROWS) 10.5".O.C. Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report D5893.04-450-18 10/24/24 *EQUIVALENCY: UL 1897-041 is equivalent to test:standard UL 1897--12. *DESIGN PRESSURE -MARGIN OF SAFETY 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by a(NFa[ll, �P�cturer, or distributing products under this report. ,� , • m a , ,L< -Ud gib• deal U i.Ss �� T • UMgL f��t' ''' Limitations i J 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended: product use outside of this report. FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details Fastener- 19 x 1-1/2" Minimum Hex Washer Head Wood Screws 5-V Crimp Roof Panel 3/8" Deck: -15/32" or.greater Plywood, or - Wood plank 21" 10.5" OPTIONAL STRIATIONS J Panel Profile Nominal 10.5" o.c. I Nominal 10.5' o.c. Isometric View Fastener #9 x 1-1/5" Min. Hex Washer Head Screw Panel Overlap . Spaced 10.5" o.c. across the Panel Deck: 15/32" or greater Plywood, or - Wood plank