Loading...
HomeMy WebLinkAboutROOFING SPECIFICATIONSArchitecton"ie Inc RECEIVE March 20, 2018 MAR 3 0 2018 Saint Lucie County Building Departme ST. Lucie county, Permitting Attn: Roof Permit Plan Review %CANNED 2300 Virginia Avenue s Ft. Pierce, FL 34982 -9gb!l r.'Mfi mv Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 13505 Okeechobee Road., Saint Lucie County, Florida Manufacturer: Metal Sales Manufacturing Corporation Profiles: 26 Ga. 5V Crimp, FL# 14645.3=R3 Code: FBC 2017; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 20' Maximum Pitch: 5 /12 Minimum Required Design Pressure: Zone1: L 24.0 Zone 2: -40.0 Zone 3: -60.0 Maximum Uplift Pressure: -74.8 PSF @ fastener spacing 16" o.c. (at panel ends 6" o.c. across panel width & at intermediate 12" O.C. across panel width) Fastener shall be sufficient length to penetrate through the deck a min. of 3/8" Underlayment: Peel &1stick or 30# felt complying with/ ASTM D226 Type II installed with spaced 6" o.c. on laps and 12" o.c. staggered in field. Roof Decking: 8d x 2�5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c. in theifield and @ 4" o.c. at edges. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 349SO Fax: 772 460 4244 FL Reg #AA26003348 1 of 1