HomeMy WebLinkAboutROOFING SPECIFICATIONSArchitecton"ie Inc
RECEIVE
March 20, 2018 MAR 3 0 2018
Saint Lucie County Building Departme ST. Lucie county, Permitting
Attn: Roof Permit Plan Review %CANNED
2300 Virginia Avenue s
Ft. Pierce, FL 34982 -9gb!l r.'Mfi
mv
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at 13505 Okeechobee Road., Saint Lucie County, Florida
Manufacturer:
Metal Sales Manufacturing Corporation
Profiles:
26 Ga. 5V Crimp, FL# 14645.3=R3
Code:
FBC 2017; Section R 905.10
Wind Speed:
160 MPH; Ultimate Design Wind Speeds
Exposure:
C
Mean Roof Height:
20' Maximum
Pitch:
5 /12 Minimum
Required Design Pressure:
Zone1: L 24.0 Zone 2: -40.0 Zone 3: -60.0
Maximum Uplift Pressure:
-74.8 PSF @ fastener spacing 16" o.c. (at panel ends 6" o.c. across panel
width & at intermediate 12" O.C. across panel width) Fastener shall be
sufficient length to penetrate through the deck a min. of 3/8"
Underlayment:
Peel &1stick or 30# felt complying with/ ASTM D226 Type II installed
with spaced 6" o.c. on laps and 12" o.c. staggered in field.
Roof Decking:
8d x 2�5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c.
in theifield and @ 4" o.c. at edges.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building
Code, and the Manufacturer's
recommendations.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 349SO Fax: 772 460 4244 FL Reg #AA26003348 1 of 1