Loading...
HomeMy WebLinkAboutNOA MODIFIED BITUMENT ROOF SYSTEMQ-J OTRINITYIERD EVALUATION REPORT CertainTeed Corporation 20 Moores Road Malvern, PA 19355 (610) 651-5847 SCANNED t� BY St Lqj'Ie EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 Evaluation Report C40710.12.13-114 FL16709-R4 Date of Issuance:12/02/2013 Revision 4: 09/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTIONS PMEtl tic® Modified Bitumen Roof Systems LABELING: Labeling s al be in accordance with the' requirements the Accredited Quality Assurance Agency noted' herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus 14-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E on 09/14/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research St Design, I.I.C. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC, d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. l�oQ'TRINIT'y ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: FlintlasticO Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2005 1519.11 Attachment Requirements RAS 117 1995 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical -properties C7290.01.08 01/16/2008 ERD (TST6049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 3519.12.03-R1 04/15/2011 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470 CTR-SC9920.01.16-111 01/W/2016 FM (TST1867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20E3A-001 01/04/2006 MTI (TST2508) Physical properties AX31GBA 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX31GBF 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 PRI (TST5878) Physical Properties CDC-032-02-01 01/16/2008 PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TSTS878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011 PRI(TST5878) Physical Properties CTC-093-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012 PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013 PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015 UL, I.I.C. (QUA9625) Quality Assurance Service Confirmation, R11656 Exp. 03/09/2020 Exterior Research and Design, LLC. Evaluation Report C40710.12.13-114 Certificate ofAutharlsatlon 09503 5T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16709-114 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 651-5847 Revision 4: 09/14/2027 Page 2 of 4 \! TRINITYIQtb 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. TABLE 1 ROLL-GOODS;;FOR FLINTLASTIG®'MODIFIED`BITUIVIEN'ROOFSYSTEMS Type Product Specification Reference Grade Type IlBase Sheets, Fl)ntlastic S U MBase _. ASTM D4601 N/A II Glasbaser" Base Sheet ASTM D4601 N/A, II All Weather/Empire- Base ASTM D4601 N/A 11 FlexiglasT" Base ASTM D4601 N/A II Flintlastic' Base 20 ASTM D4601 N/A II Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II Yosemite®, Venting Base ASTM D4897 N/A II PI Sheets y Flintglas® Ply 4 ASTM D2178 N/A IV Flintglas® Premium Ply 6 ASTM D2178 N/A VI Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Flintlastic® STA ASTM D6222 ' S I Flintlastic® STA Plus ASTM D6222 S Cap Membranes (APP) Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Flintlastic® GTA ASTM D6222 G I Flintlastic° GTA CoolStar- ASTM D6222 G I Flintlastic® GTA-FR ASTM D6222 G I Flintlastic® GTA-FR CoolStarlm ASTM D6222 G I Base/Ply Membranes (SBS) Flintlastic SA PlyBase ASTM D1970 N/A N/A Black Diamond° Base Sheet ASTM D1970 N/A N/A Flintlastic SA Mid Ply ASTM D6163 S I Flintlastic Ultra Glass SA ASTM D6163 S I Flintlastic Base 20 ASTM D6163 S I Flintlastic- Base 20 T ASTM D6163 S I Flintlastic Ultra Poly SMS Base Sheet ASTM D6164 S I Cap Membranes (SBS} Flintlastic FR Dual Cap ASTM D6162 G I Flintlastic SA Cap FR ASTM D6163 G I Flintlastic SA Cap FR CoolStar"" ASTM D6163 G I Flintlastic Cap 30 ASTM D6163 G I Flintlastic Cap 30 CoolStar'" ASTM D6163 G I Flintlastic FR Cap 30 ASTM D6163 G I Flintlastic FR Cap 30 CoolStarTM' ASTM D6163 G I Flintlastic FR Cap 30 T ASTM D6163 G I Flintlastic,�FR Ca _30 T CoolStarTM ASTM D6163 G I F intlastit SA Cap ASTM 06164 G Flintlastic SA Cap-C-007Star" ASTM D6164 G I Flintlastic FR-P ASTM D6164 G I Flintlastic FR-P CoolStarl ASTM D6164 G I Flintlastic GMS ASTM D6164 G I Flintlastic GMS CoolStar" ASTM D6164 G I Flintlastic GTS ASTM D6164 G II Flintlastic GTS CoolStarTM ASTM D6164 G II Flintlastic GTS-FR ASTM D6164 G II Flintlastic GTS-FR CoolStarTM' ASTM D6164 G II Flintlastic Premium FR-P ASTM D6164 G II Flintlastic Premium FR-P CoolStarTM' ASTM D6164 G li Exterior Research and Design, I.I.C. Evaluation Report C40710.12.13-114 Certif ate ofAuthorizotion #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL36709-R4 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 4: 09/24/2017 Page 3 of 4 '\,JTRInJITY I ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.6 The maximum design pressure 'for the selected base assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. This is already addressed in the Appendix tables via "N/A" reference if the baseline system is "Not Applicable" to Zone 1 design pressure requirements. 5.7 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirementsfor the system. Testing and analysis shall be in accordance with ANSI/SPRI FX- 1 or Testing Application Standard TAS 105. 5.8 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing. Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1),1609.3(2) or 1609.3(3). 5:9 All products in the roofassembly shall have quality assurance in accordance with FAC Rule 611320-3. 6. INSTALLATION: 6.1 Flintlastic° Modified. Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind -load resistance are set forth in Appendix 1. System listings are based on allowable wind loads per FBC 1609 and a 2 to 1 margin of safety per FBC 1504.9. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 14-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report C40710.12.13-R4 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.16709-114 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 65145847 Revision 4: 09/14/2017 Page 4 of 4