HomeMy WebLinkAboutNOA- MODIFIED BITUMEN ROOF SYSTEMSCANNED
By
S$ Lucie ft*
MIAMI
MM72E
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miaini,Tlbrida 33175r2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.mhimidade.gov/cconomX'
CertainTeed Corporation
'18 Moores Road
Malvern, PA 19355
�i
f
j RECEIVED
k
MAR 3 0 2018
i ST. Lucie County, Permitting
SCOPE: '
This NOA.is being issued under the applicable,rules.arid regulation's governingthe use of construction materials. The
documentation submitted has, been reviewed and accepted by Miami -Dade County RER - Product Control Section to be,
used in -Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ):
This NOA shall not be valid after the expiration date stated below. The Miami-D'ade County Product Control Section
(In Miami Dade County) and/or the AHJ: (in areas'other than Miami Dade County) reserve the right to have this
product: or material tested for quality assurance purposes. If this product or material fail's.to perform in the accepted
manner, themanufacturer will 'incur the expense of such testing and the AHJ,. may immediately revoke, modify, or
suspend the use of such product or material within'their jurisdiction. RER reserves the right to revoke this acceptance,.
if it is determined by Miami -Dade County Product Control Section that this product or material. fails .to meet, the
requirements of the applicable building code.
This product is approved as described herein, and has: been designed to.comply with the Florida Building Code
including the High Veloci . -Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name, or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall .be considered. after a renewal application has been fi led and'there has been no change
in the applicable building,code negatively affecting the performance offhis.product.
TERMINATION of this NOA will occur after the expiration .date 'or ifthere has been a'revision.or change in the
materials, use, and/or manufacture of the product or process. Misuse;of this NOA as an endorsement of any product,
for'sales, advertising or any other purposes'shall automatically terminate this NOA. Failure to, comply with any section
of this,NOA shall be cause.for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the mords Miami -Dade County, Florida, and followed by, the.
expiration date may, be displayed 'in advertising literature. If any portion of the'NOA is displayed, then it.'shall be done
in its entirety.
INSPECTION:. A copy of this entire NOA shall be provided to the user by the: manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #1,4-0224.03 and consists of pages 1 through 42.
The submitted'documentation was reviewed by Alex Tigera.
�V
MM-1-DADECOUNTY Ex iration Date: 06/19/18
Approval Date: 09/24/15
FILE COPY Page 1 of 42
NOA No.: 14-0529.02
ROOFING SYSTEM APPICOVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum Design Pressure:
-127.5,psf.
TRADE NAMES, ORPRODUCTS .MANUFACTURED OR LABELED By APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
All Weather/Empire Base
39%!`x651107;
ASTM D4601, Type: Asphalt coated, fiberglass reinforced'
Sheet
Roll weight'. 70 lbs..
ii
base sheet..
(2-squareg)
UL Typo G2
Flexiglas. Base She6t.
39 %" x.,98'9";.Roll
ASTMD 4601, Type Modified Bitumen coated fiberglass
weight: 90 lbs,.
11
base, sheet.
(3. squares)
UL Type G2.
Flintlastic Base 20
39'Ys" x 49'6"; Rci'll
ASTM D 610,
Modified Bitumen coated fiberglass
weight: 90, tbs.
Grade $,, Type I
base sheet.
(1.5 squares)
Flintglas Ply Sheet Type TV
39 '/s" x 1647'; Roll
ASTM D2178, Type Fiberglass, asphalt impregnated ply sheet.
'weight: 38 lbst
IV
(5 squares)
UL Type G
Ffiritglas Premium Ply Sheet
39 x 1647r;Roll
ASTM D 2.178, Type, Fiberglass, asphalt impregnated ply
Type VI
weight:. 40 lb - s.
VI
sheet.
(5 squares)
UL Type GI
Flintlastic STA
39 %" x 32' 10"; Roll
ASTM D 6=,
'Smooth surfaced APP Modified
weight! 87 lbs.
Grade S, Type I
Bitumen me M-brano- with non -woven
(I square)
polyester mat reinforcement for torch.
application.
Flintlastic GTA
39 '/8" x 32' 10"; Roll
ASTM. D 6221
Granule surfaced APP Modifi6d
weight: 105 tbs.
Grade Q Type I
-Bitumen- membrane with non -woven
(I square),
pbly0ster mat reinforcement for torch
application.
Flintlastic GTA-FR
30 Ys" x 321 10"; Roll
ASTM D,6222
Granule suffAced'APP Modified
Weight: 165 tbs.
Grade G; Type I'
i Bitumen membrane with non -woven
(I square
polyester mat reinforcement for torch
application.
Flintlastic, GMS
30 %" x 32' 10"; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight; 94 tbs.
Grade G, Type I
-Bitumen membrane,with non -woven
(I square)
polyester mat reinforcement for mop
application.
NOA No.: 14-0529.02
Expiration Date: 06/19/1.8
,Approval Date: 09/24/15
Page 2 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE I
Test
Product
Product
Dimensions
Specification
Description
Flintlastic Premium GMS
39 /s" x 32' 10"; ROII
ASTM D 6164,,
Granule surfaced SBS Modified
weight: 101 lbs.
Grade G, TypelI
Bitumen membrane with non -woven
(I -square)
polyester mat reinforcement for mop
application,.
F_ lintlastic FR-P
393/s" x 3,2' 10"; Roil
ASTM D 6164,
Fire resistant,granule-surfaced SBS,
weight: 101 lbs.
Grade G, Typ6I
Modified Bitumen Membrane with
(1 square)'
non -woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
3931s".x 32' 10"; Roll'
ASTM D 6164,
Fire resistant, granule•surfaced SBS
weight:,101 lbs.
Grade G, Type II
Mollified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement.for mop application.,
Flintlastic FR Dual Cap
39 3/s" x 3,2' 10."; RQfI
ASTM D 6162;,
Granule surfaced SBS modified
weight: 103 lbs.
Grade G, Type I
bitumen membrane with a•nonwoven
(1 square)
polyester/fiberglass composite "mat
reinforcement for use in. cold or mop
applications.
Flintlastic FR Cap 30
39 %" x 32' 10"; Roll
ASTM D:61"63,
Fire resistant, granule surfaced SBS:
weight: 86 lbs:
Grade G, Type I
Modified Bitumen -membrane with
(l square)
fiberglassmat reinforcement for mop
applications.
Flintlastic FR Cap 36 T
39-3/8" x 32' 10"; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 100 lbs.
Grade. G; Type I
Bitumen membrane with fiberglass
(1 square)
mat reinforcement for torch
application.
Flintlastic Base 20 T
3:9-318",x 33.'; Roll,
ASTM D 6163,
Modifed.Bitumen, coated fiberglass
Weight: 8.1 lbs.
Grade S, TypeI
base sheet for torch application.
(1 square)
Flintlastic FR Cap 30 CoolStar
'39 a/s" x 32' 16"; Roll
ASTM'D 6163,
.Fire-resistant, granule surfaced SBS
tiveigh't: 881bs.
Grade G, Type I
'Modified Bitumen membrane with
(1 square)
fiberglass mat "reinforcement for mop
,applications. Covered with reflective
'CoolStar Coating.
Flintlastic FR Cap 30 T
39 %" x 32',10" Roll
ASTM D 61.63,
Fire resistant, granule, surfaced SBS
CoolStar
weight: 1,02.lbs.
Grade G, Type I
Modified Bitumen. membrane with
(1 'square)
fiberglass mat reinforcement for mop
applications: Covered with reflective
CoolStar Coating.
NOA No.: 14-0529.02
MIAMI•DADECOufVTY Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 3 of 42
i
TRADE NAMES OF PRODUCTS MANUFACTURWOR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic GTA CoolStar '39 44" x: 32" 10"; Roll ASTM D .6222, Granule surfaced APP Modif eed
weight: 106 lbs. Grade G. Type I Bitumen membrane with non -woven
(1 square) polyester mat reinforcement for torch
application. .Covered with reflective
CoolStar Coating.
Flintlastic GTA-FR CoolStar
39 3/s" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP'Modified
weight: 1061bs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for -torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS'C,00lS:tar
39 3/$" x 32' 10'; Roll'
ASTM D 6164,
'Granule.sur-faced SBS Modified
weight: 97 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application. Covered, with reflective
CoolStar Coating.
Flintlastic.Ptemium GMS
'39 3/8" x 32' 10"; Roll
ASTM D 6164;
Granule surfaced SBS Modified
CoolStar
weight: 1031bs.
Glade G, Type II
Bitumen -membrane with non woven
(1 square)
polyester mat reinforcement for,mop
application. 'Covered with reflective
CoolStar Coating.
Flintlastic FR-P CoolStar
39 3/s" x 32' 10"; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 1,03 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(I square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Premium FR-P
39 3/a" x 32' 10";. Roll
ASTM D 616.4,
Fife resistant, granule surfaced SBS
CoolStar
weight: 103 lbs.
Grade G, Type Il
Modified Bitumen Membrane with
'(1 square)
.non -woven polyester mat.
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Ultra. Poly S.MS
39 3/8"-x 32' 101?; Roll
ASTM D'6164,
Smooth surfaced SBS Modified
Base Sheet
weight: 90 lbs. (1
Grade S, Type I
Bitumen Membrane with non -woven
squares)
polyester mat reinforcement for -mop
applications.
Glasbase Base Sheet
36" x 98" 9"; Roll
ASTM D 4601, Type Asphalt coated, fiberglass base sheet.
weight: 75 lbs.
II,
(3 squares)
UL Type G2
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 4 of 42
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product Dimensions
Flintlastic Poly SMS Base 39 /L " x 64'.3";_ Roll.
Sheet weight: 90 lbs.
(2 squares)
Yosemite Venting Base. Sheet 39 . x 32' l 0' ; Rol I.
weight: 85 lbs..
(l. square)
Flintlastic APP Base T 39 3%s" x 65' 4"; Roll
weight: 100 lbs.
(2 squares,)
Flintlastic Ultra Glass SA 39'%"-x 3Y 1.1" ; Roll
weight: 73 lbs-
(I square).
Black�DiamondTM Base Sheet 36" x.68'7' ; Roll;
weight: 78 lbs.,
(2 squares.)
Test'
Product
Specification
Description
AS D 4601;,
Modified Bitumen coated polyester
Grade S, Type. II
base sheet.
UL Type G2
ASTM D 3909
Mineral Surfaced fiberglass reinforced
ASTM D 4807, Type buffer.sheet,
II
UL Type G3
ASTM D 6509
Modif ed'Bitumen coated fiberglass
base sheet.,
ASTM D 1970
ASTM D 1970
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description
FlintBoard ISO
Polyisocyanurate. foam insulation
FlintBoardH ISO
Polyisocyanurate foam insulation
ACFoam 4I
Poly isocyanurate foam insulation
High Density. Wood Fiberboard
Wood fiber insulation board
Perlite Insulation
Perlite insulation board
DensDeck, DensDeck Prime
Water resistant gypsum board
H-Shield
Polyisocyanurate foam insulation
ENRGY '3
Poly .isocyanurate foam insulation
ENRGY 325 PST
Polyisocyanurate foam insulation
Multi -Max FA-3.
Polyisocyanurate foam insulation
SECUROCK Gypsum -Fiber Roof Board
homogenous fiber reinforced
CMILAAMI-DMADE COUNTY
�Fj...f
ynvj
Self -.adhering, fiberglass reinforced,
SES modified bitumen base/ply-sheet.
Self -adhering, fiberglass reinforced
;modified bitumen base sheet
Manufacturer
ith Current NOA
CertainTeed Corporation
CertainTeed Corp.
Atlas. Roofing, Corp.
Generic
Generic
Georgia Pacific Gypsum.LLC
Hunter Panels-LLC:
Johns Manville Corp.
Johns Manville Corp.
RMax Operating, LLC
USG Corp.
N.OA No.: 14-0529.02
Expiration. Date: 06/19/18
Approval Date; 09/24/15
Page 5 of 42
,APPYtOVED FASTENERS:
TABLES
Fastener
Product
_Product.
Description,
Dimensions
Manufacturer
(With Current NOAI
Number
Name
1.
Trufast 91'2 DP Fastener
Insulation fastener for wood
various,
Altenloh, Brunch & Co. U.S.,
and steel decks ,
Inc.
2:
Trufast 3" Metat
Galvalume steel' plate
3" round
Altenloh, Brinch & Co. U.S.,
3.
Insulation Plate
F1intFast`#12
Coated, carbon steel screw,
various
Inc.
CertainTeed Corp.
4.
F1intFast.3" Insulation
Galvalume AZ50 steel plate;
Xi round
Certain -Teed Corp.
5.
Plate
FliritFast #14
Insulation fastener for wood
various
CertainTeed Corp.
.and steel decks
6.
Simplex MAXX .Cap
Polyinor fastner
'1" long
Simplex Nails, Inc.
7.
OMG 412 Standard
Insulation fastener for wood
various
ONIG, Inc.
Roofgrip
and steel.
8.
OMG3" Galvanized Steel
'Galvalume stress plate
3" round
QMG;,Inc.
9.
Plates
Trufast 914 HD Fastener
Insulation fastener for wood
various
Altenloh, Brunch & Co. US.,
and steel decks.
Inc.
10.
OMG Heavy Duty
insulation and, membrane
'Various
OMG, Inc:
fastener
IL
OMG 3 in. Round Metal
Galvalume AZ50 steel plate
3" round
OMO; Inc.
Plates
12.
AccuMac Hextra
Carbon steel fastener'
Various
OMG,'lnc.
13.
AccuTrac Plates
Galvalume. stress plate.
3" square
OMG, Inc.
14.
AccuTrac Flat Bottom
A2-SSaluminized steel plate
31' square
O.MG; Inc.
Plates .
NOA No.: 14-0529.02
MIAMI-DARE eourrnr Expiration Date: 06/19/18
LIM
Approval Date: 09/24/15
Page 6 of 42
APPRovF, D SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied accorAing to manufacturer's application instructions. Any, coating, listed
below, used as a surfacing, must be. listed within it current NOA.
System Number Manufacturer Application
1, Generic Gravel applied at 400 Ibs/sq., adhered with flood coat ofasphalt at
6Q lbs/sq.
2', Generic Slag applied at'300 16/ _adhered with flood" coat of asphalt -at 6Q
Ibs/sq
;:. Karnak Corp: Karnak (#97 AF) Fibrated-Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed'Corp.. FlintCoat A450 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC:4212 Fibered Aluminum Roof. Coating applied at an
appjIicat'ion rate of 1.5 gal/sq.
6. GardnerAslihalt Corp. APOC' #400 Sunbrite applied at an, application rate of 3 gal./sq.
NOA No.: 14-0529.02
MIAMMAUeeouNTY Expiration Date: 06/19/18
Approval Date: 09/24/15
Page:7 of 42
i
EVIDENCE SUBMITTED:
Test ¢ency/Identifier,
Name
Report
Date
Factory Mutual Research Corp.
FM.4470
3Y8A1.AIVl.
03/23/96.
04/,04/97
FM 447.0,
OD3A3.AM
FM 4470
2DOAO.AM
12/23/98
FM 4470.
1D7A4.AM
11/09/9.8
FM 447,0
163,9046
:06/15/10
FM 4470
304.8520
09/1'9/13
Undemeiters. Laboratories, Inc.
UL 790'
R11656
01/11/13
United :States Testing Company
AST.M,;D 5.147
97457-4
06/03/88
12/02/87
ASTM D.5147
97457-2R
Momentum Technologies, Inc.
ASTM D 4601
AX31 G81)
09/05/08
ASTM D6164
AX31G8F
06/05/09
ASTM D6222.
AX3 tG8G
06/05/09
ASTM D 3909/ D 4897
AX31 G8C
09/05/08
TrinityjERD
TAS 114(J)
3504.0.6.011-1
06105/0.1
TA'S 1:14(J)
3507.0, .99=1
04/18/0.1
TAS 111 (B)
3503'.10.0-6
10/10/,06
TAS 117(13)
06490:04.07-R1
�06/27/07
TAS 114 (H)
Lett'er'
o4/05/06
TAS 114
3533.01.06
0.1 /06/06
TAS 114
3521.67.04
07/29/04
TAS 117 (B)/ ASTM D: 6862
C.85.00SC.11.07
l 1/30/07
'TAS, 1114
C8370:08.08
08/19/08
.ASTM Physical Properties
C10.0.80,09,08-R4
03/25/10
ASTMD6164/D4798
01410.0.1.11-2
01/10/11
ASTM D4601
C40050.09,12-1
09/28/12
ASTM D1970
C40050.09.12-2
0.9/28/12
ASTM D5147/D4798
C31410.10.10-R1
11/01/1.2
ASTM .D5147/D4798
C31410.'OL-11-1-Al
11/01/12
M, ASTD 1876
C35460.05.1'1
00/16/ 11
ASTM D 1876, TAS i 14 (14),
C42116.08.12
' 8/13/12
TAS 117 (B)
FM 4474/TAS 114
C3,9:670.08.12
08/20/1.2
TAS 117B
C35500.02.11
02/0.9/11
ASTM D4798
0141O-QI J1-2A R1
'02/21/13
ASTM D479.8
C31410.12.13
12/.05/13
ASTM D6222
C40050.12.13-R 1
12/31 /13
TAS 117, TAS 114
C30310.12.09-R1
03/07/14
ASTM D 18,761 TAS 114 (14),
C.45620.03.14
03/27/ 14
FM. 4474
ASTM`D1876, TAS 114 (H).
C47320,03.14-R1
04/01/15
FM 4474
PRl Construct►o» Materials
ASTM D6163
CTC-032-02-01
01 /22/08
Technologies LLC
ASTM D6163
CTC-066-02-01-
08/09/11
ASTM D6222
CTC-670-02-01
08/09/11
NOA No.: 14-0521.02
MAMMAUB COUNTY Expiration Date: 06/19/18
Approval Date: ll9/24/.15
Page 8 of 42
EVIDENCE SUBMITTED:
Test Agency/Identifier. Name;.
Report
Date
ASTM D6164/D4798
C.TC-093=02-01
08109/11
ASTM D2178
CTC71.22-02.01'
03/13/.12
ASTM 02.178
CTC-1,23=02-01.
03/13l12
ASTM; D4601
CTC-127-02-01
.03/13/12,
ASTM D6163
CTC-128-02-01
ASTM D61.63
CTC=129-02-01
06/11/12
ASTM D6164
CTC-132-02'-01
06/11/12
ASTM D6164
CTC-1'62-02-01
05/09/13.
ASTM D61`64
CTC=16.1'-02=01
05/09/13'
ASTM DR62
CTC-183-02-0.1
10/02/13
ASTM D6164
CTC-1,90=.02;O1
12/61/13
ASTM D 1970
CTC-19.9-02-01
01 /22/.1.4
NOA No.: 1.4-0529.02
1 MIAMI-DARE COUNTY
� � Expiration Date: 06/19/18
Approval .Date: 09/24/15
Page 9 of 42
MembraneType:
Deck Type 1I:
APP Modified
Wood, Non -Insulated
Deck Description: 19A211 or greaterplywood or wood plank
System Type'E(3): Base'sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply,of All Weather/Empire'Base Sheet, Yosemite;Venting.Base Sheet, Flexiglas Base
Sheet, Flintlastic Poly SMS Base, Sheet, Flintlastic. Ultra Poly SMS Base Sheet"Glasbase. Base.
Sheet'or Flintglas Premium Ply Sheet Type VI mechanically attached,as detailed below.
Fastening: Base sheet shall be lapped 4" and fastened With I l ga.:aririular ring shank,hails and_approved'tin
caps' 8"o.c: in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet; One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet; 'Glasbase
(Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 201 Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas. Ply Sheet Type, IV or, Flintglas.Prernium Ply Sheet Type VI adhemd'in
a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
.or one, ply, ;of Black Diamond Base, Sheet oc Flintlastic Ultra Glass SA self adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane: Flintlastic GTA. Flintlastic GTA CoolStar, .Flintlastic'GTA-FR or Flintlastic GTA-FR CoolStar
torch adhered to base/ply sheet.
Surfacing: Any of the approvedsurfacing/coating options listed in Table 4.,
(Optional)
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 23 of 42
4 ` �
WOOD DECK SYSTEM LIMITATIONS:
A slip sheet is required with Ply 4 and Ply,6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Diiector for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with-Troduct Control
Approval guidelines. All oiher-layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range of and at a rate 20-40 lbs./sq„ or -mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes ale acceptable for mechanical attachment. When applied. in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/orrecovery board insulation' panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the: base sheet shall be applied rising spot
mopping with approved asphalt, 12" diameter circles; 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side- lap and one down the center of the 'sheet allowing a continuous area of ventilation. Encircling, of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross "ventilation. Asphalt
application of either system shall, be at a minimum rate. of 12 lbs./sq.
Note:, Spot attached'.systems shall be limited ,to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment, is base&on a Minimum Characteristic Force (F') value of 275 IV., -as
tested in compliance with Testing Application Standard TAS 105. If the fastener -value, as field-tested, are below
275 lbf. insulation attachment shall not, be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet. or membrane attachment is based on a minimum
fastener resistanc
e value in, conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less_tiian iliat.required, a$determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener :spacing.shall utilize the. withdrawal resistance value
taken from Testing Application.Standards TAS ,105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Per`imeter and corner areas shall comply with the enhanced uplift; pressure requirements of these areas. Fastener
densities, shall be increased for both insulation and base :sheet as calculated in, compliance with Roofing
Application Standard RAS I17. Calculations p. epared, signed. and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this,NOA, General ,Limitation #0 will not -be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard'RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall -be applicable:to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permittedfor enhanced fastening at
enhanced pressure,zones (i.e.. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 6.1 G20 3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 140529.02
MIAMI®LINTY
Expiration Date: 06/19/18
Approval Date: 09/24/15