HomeMy WebLinkAboutproduct approval metal roofing' iibmu to
i ionaa timiaing L;oae unllne
m
^
,
•�
acts Home ; Log In I User Registration ! Hot Topics
I suIr% ^ A£ & Facts I Publications I FBC Staff BCIS Site Map' Links I search
Florida
ProductApprovalStp
(tia-1
BY
Public User
�L
�4�Q�COON`USER:
3��`ce�
Product Approval Menu > Product or Application Search >
A lication Lispp lion DetailCEIVEDFL
# I
FL17022-R7
Application Type
RevisionCode
LR
302018
Version �
2017
Application Status
Approved ount Y, Permitting
Comments I
08/18/ 7v. date reapply 08/21/17
Archived i
i
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, Fl- 34990
i
(772)872-8034
flvaiidation@yahoo.com
Authorized Signature I
Richard McKuhen
flvalidation@yahoo.com
Technical Representative
Richard McKuhen
Address/Phone/Email I
2160 SW Poma Drive
i
Palm City, FL 34990
872-8034
JEA
rchard@emfab.net
richa
ST. LUCIE COUNTY BUILDING DIVISIgRho
Quality Assurance Representative
REVIEWED FOR COMPLI C
Address/Phone/Email
REVIE.
DATE
Category
Roofing PLANS AND PE MIT MUSTOE KEPT ON JOB
Subcategory
Metal Roofing SITE OR NO INSPECTIONS) WILL BE MADE
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report THESE PLANS AND ALL PROPOSED WORK
Florida License
PE-49704 ARE SUBJECT TO ANY CORRECTIONS
QUIRED BY FIELD INSPECTORS THAT
Quality Assurance Entity
Keystone CertificatiRE
�i k 913E NECESSARY IN ORDER TO
Quality Assurance Contract Expiration Date
04/22/2024
COMPLY WITH ALL APPLICABLE CODES.
Validated By
Zachary R. Priest, P.E.
L" Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard)
Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By CONCEALED FASTENERS OR ATTACHMENTP _
ARE THE RESPONSIBILITY OF THE
Sections from the Code CONTRACTOR OR RECORD F71 �� �•: ��
https.11www.floddabuilding.org/prlpr app dU.aspx7param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoRp/*2bGxHGxFe5QkCHzEgvOQveegp/o3d*/w3d 1/4
1/8/2018
I
49 i lorida Building Code Online 40
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15132" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for!conditions. Install the
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "SV Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No I
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No i
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A;
Evaluation Reports
Other: Refer to evaluation report for conditions.Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed In
.this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssnodf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly In compliance with the
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed in this report and applicable code
seam 24ga ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside! HVHZ: Yes
ALUMINUM ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
Installation method listed in this report and applicable code
ALUMINUM ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
17022.5 15 - "1 in. Nail Strip" (115) 11" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No ,
Design Pressure: +N/A/ Table A
Installation Instructions
FL17022_R7_11 _ FL 17022.5 1.0 NAILSTRIP ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
https://www.floridabuilding.orgtprlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFeBQkCHzEgvOQveeg%3d%3d 2/4
1/8/1U18 Florida Building Code Online
Other: Refer to evaluation r ort for conditions and FL17022 R7 AE FILMS 1.0 NAILSTRIP ssrodf
limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes
installation method listed in this report andlapplicable code
sections of FBC, Refer to manufacturer's installation
instructions.
17022.6 6 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP_0.032
Approved for use outside HVHZ: Yes' ALUM ssr.Ddf
Impact Resistant: No 1 Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A i Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and Evaluation Reports
limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0,032
installation method listed In this report and applicable code ALUM ssr.Ddf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
17022.7 17 - "1.5 in. Nail Strip" (115)
i
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssrodf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail StriD_26GA ssr.Ddf
Created by Independent Third Party: Yes
17022.8 8 - "EMAXi Rib" (115) 29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssr.Ddf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A; Evaluation Reports
Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf
limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 19 - " PBR MAX" (R5) 126 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssrodf
limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturers Installation
instructions.
BaCIC N6Y.t
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-IM
The State of Florida Is an AA/EEO employer. Conyrioht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
FM 0 ® M Im
https:llwww.floridabuilding.org/pdpr app dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 314
M
of
i
Compliant with Florida Building Code 2017 (61 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
i
160 SW Poma Drive
Palm City, FL 34990
Product: 5 •V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. OA2 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1S07.4.3
Fastener 1(Method 1 Attachment)•11#9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements) i
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
i
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" ox.
16" ox.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" O.C.
12" ox.
12" O.C.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report aS893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 itt *Design pressure margin of safety 2:1
• •� H
Locke Bowden, P.E. does not have, not williacquire a financial In q �� cq q�►m'�iafacturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by atly coniparil mAbilbatureP, or distributing products under this
report.
AczT' Tc ;4r /r
�, 40R10 N
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Undedayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
%- Fasteners -
#9 x 1-1/2' Min. or
#10 x 1-112' Mln. perTabfe A' far Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
Dedc:
15/32' or greater Plywood, or
Wood plank
24"
318"
T 11
N--l— C TIONALSTRIATiONs
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
LT9_x_1=1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
I ` Deck-15/32" or greater
Plywood, or
-Wood plank