HomeMy WebLinkAboutPRODUCT APPROVAL- ROOFING UNDERLAYMENTSBusiness iProfessional1 1
BCIS Flame Log In • User Registration Hot Topics Submit Surcharge Stets &Facts . PubllpUons I FBC Staffff aQS Slte Map Unks I Search
ProductApproval� "
t;•.". 2i USER: Public User ..
Product Approval Menu > Product orAoollration Search > Aoallmtion List > Application Detail
• .FL #... FL2569-R13
Application,Type • Revision ST. LUCIE COUNTY BUILDING- DIVISION
..Cade Vetsion ......:...2017 '
REVIEWED. FO.R. COMPLIM
Application Status Apprtitied REVIEW i $Y .
DATE L
' Corliments
PLANS AND PERMIT MUST BE K ON JOB
7 • , .
SITE OR NO INSPECTION
Archived . S WILL BE MADE
"Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400-
memath ieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathleu @soprema.ca
Technical Representative
Address/Phone/Email i
I
Quality Assurance Rep lesentative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO,
COMPLY WITH ALL APPLICABLE CODES.
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819).478-2400 Ext 3327
memathleu @soprema.ca
Jean-Francols Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Roofing
Uiiderlayments
Evaluation Report from'a Florida Registered Architect or a Licensed
Florida Professional Engineer
r Evaluation Report - Hardcopy Received
RobertJ. M..Nieminen
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
2 Validation Checklist - Hardcopy Received
Fi 7Sa9 -R13 COI 2017 01 COI Nieminen.odf
Standard
ASTM D1970
2015
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
TAS 110
2000
UL 1897
2012
CONCEALED FASTENERS OR ATi ACHMENTS FILE- COPY
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
i
Equivalence of Product Standards
Certified By
Sections from the Cade
Product Approval Method Method 1 Option D
Date Submitted 10/09/2017
Date Validated 10/11/2017
Date Pending' FBC Approvals 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or
Description
Name
2569.1
Soprema Roof
Self adhering roof underiayments
Underiayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL2569 R13 II 2017 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
R13: d
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for
Limits of Use. 2.) The design pressure.
Evaluation Reports
FL2569 R13 AE 2017 10 FINAL -ER SOPREMA CA UNDERLAYMENTS FL2569-
R3
Created by Independent Third Party: Yes
noted herein pertains to,underlayment
systems used beneath adhesive -set tle
systems. Refer to ER Section 5.6.4 for
details.
Back Next
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address. released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional, mall. If you have any questions, please contact 850.487,1395. -Pursuant to Section 455.275
(1), Florida Statutes, effectiveOctober 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
W ® 99 12
Credit Card
Safe
I
EXTERIOR RESEARCH & DESIGN, LLC.
_
Certificate of Authorization #9503
'\JERTIUNIT.Y,
353 CHRISTIAN STREET, UNIT#13
D
I
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
Soprema, Inc.
Evaluation Report S18010.0&09-R11
1640 rue Haggerty
FL2569-R13
Drummondville, Quebec J2C 5P8 Canada
Date of Issuance: 06/15/2009
(819) 478-2400
Revision 11:10/06/2017
SCOPE: i
This Evaluation Report is issued under Rule 61G20-3 and the'appllcable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for .use of the product under. the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6ei Edition (2017) Florida Building Code
sections noted herein. i
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is dispIayed,.then it shall be done in its entirety.
INSPECTION: Upon request, .a copy of this entire .Evaluation Report shall be provided to -the user by the manufacturer or
its,distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
' I
Prepared by:
j
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/66/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor.does it intend to acquire or will it, acquire,' a financial interestin any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD.is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,'P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.,
5. Thisis a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or. previous versions thereof, is/was used forpermitting or design guidance unless retained
specifically for:that purpose.
\I TRINIIYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1904.3.1
Wind Resistance
FM 4474
2011
1504.3.1 i
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
Kniivll
Examination Reference
Date
ERD (TST6049)
ASTM D1970 / TAS 110 2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties 2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110 2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance 2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance 2779.11.05-111
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110 S7120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110 S13190.02.09-111
04/01/2010
ERD (TST6049)
ASTM D1970 / TAS 110 S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D (CER1592)
HVHZ Compliance 15-0508.04
09/24/2015
ICC-ES (EVL2396)
2015 IBC Compliance ESR-1524
03/01/2017
PRI (TST5878)
Physical Properties SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS
modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
4.2 Lastobond Shield
is a self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof
underlayment;'available
in 3.3 ft x 65 ft rolls; meets ASTM D1970.
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment; meets ASTM D1970.
Exterior Research and Design, LLC.
Evaluation Report S18010.06.09-R11
Certificate of Authorization #9503
6zH EDITION (2017) FBC NON-HVHZ EVALUATION
FL2569-R33
Soprema, Inc.
Revision 11:10/06/2017
Page 2 of 8
TRINITY ( ERD
4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch; meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high. temperature, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.8 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970.
4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment; meets.ASTM D1970.
4.10 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.11 RESISTO L81236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with; a 36-inch sheet width; meets ASTM D1970.
4.12 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.13 RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with a 44-inch sheet width; meets ASTM D1970.
4.14 Colphene FIR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made, to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
T{1BLE1 ROOFCOVER OPTIONS
` `
Asphalt
Nail -On
Foam -On
Metal
Wood Shakes &
Slate
Underlayment
Shingles
Tile
Tile
Shingles
Lastobond TU HT
Yes
Yes
Yes
-See 5.5.1
Yes
Yes
Yes
Lastobond Shield / Pro HT-N / RESISTO SA
Yes
'
No *
ar ;';'No
No
Yes
Yes
SMOOTH PLY40
Lastobond Shield HT/ Pro HT-S
Yes
+", i (Vo , ;
' ++' No
Yes
Yes
Yes
Lastobond Eaves Protection Sheet /
YesNo
Yes
Yes
Lastobond 195
y5.
f..
Lastobond ECO / RESISTO LB1236, Grip-
r` "
Rite Eave & Valley Protector / RESISTO
Yes
r No, ;.
No
No
Yes
Yes
LB1244
Exterior Research and Design, I.I.C. Evaluation Report S18010.06.09-R31
[Mate ofAutlroriration #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1113
Soprema, Inc. Revision 11:10/06/2017
Page 3 of 8
�I I KINITYIERD
Colphene FR GR Yes. Yes Yes R No ' Yes Yes
See
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
,, ', , , _ TABLE 1/� ALLOYVABLETILEtADHE.SIVE,� UNDERLAYIVIENT CQMBINAT10NS1 n
Adhesive
Florida Product Approval
Underlayments
Dow TileBondTM'
FL22525
Lastobond TU HT
ICP Adhesives Polyset" AH-160
FL6332
Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
D Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to
installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond
Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
L81236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR
GR applied to:
Dens Deck Prime;'SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807.
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report S18010.06.09-R11
Certifrcoteofquthori:odon#9503 If EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1113
Soprema, Inc. Revision 11:10/06/2017
Page 4 of 8
�l TRINITY I ERD
5.6.3 Bond to Mechanically Attached Base Laver:.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU 'HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
➢ ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and, reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind
pressures.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure = -250.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or
weighted roller to ensure there are no voids, and ensure there are no voids/bridging at
side and end -laps.
#4 Maximum Design Pressure = -60.Op :
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on the systems carry a
Maximum Design Pressure of -45 psf.
Exterior Research and Design, U.C. Evaluation Report S18010.05.09-R11
CeWficate ofAuthoriration #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R33
Soprema, Inc. Revision 11:10/06/2017
Page 5 of 9
I
V TRINIIYIERD
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (64-12), Appendix A, Table 3A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention. Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation.
Lastobond Shield,'Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40,-Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT.or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations RAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
_' TABLE_2 SII E SLIPPAGE [IMIiATIbNSFOR DIRECT
DECK TILE fNSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max.10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Lastobond TU HT ;
Lugged
Colphene FR GR
Flat
Max. 10-tile stack 5:12
Lugged
Max. 10-tile stack 6:12
Exterior Research and Design, LLG Evaluation Report S18010.06.09-R11
certijFcate of Authorization #9503 e" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R13
Soprema, Inc. Revision 11:10/06/2017
Page 6 of 8
V I KIMTY I ERD
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable).
6 3 `z Lastobond"fUfHT, Lalstobond Shleldy Lastobond Pro HT N, RESISTO SA S111(00'fH PLY 40, Lastobond Shleld
fi�i;jTiastobond Pro.HTS,1,astobontl Eaves Protectron-Sheet`, Wstobond 196, Lastobond Eco, Lastobond`
.' :;�. SmoothrSea( HT, RESISTO �61236, Grlp Rlte fare"&Walley Protector,;RESISTO Lg1244 or Colphene FR,GR '
F_3.1 shall be installed In COMDliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be Installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge., Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far•as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and Soprema published requirements for tile staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Exterior Research and Design, U.C. Evaluation Report S18010.06.09-R11
CenVcate o/Authorization #9503 6n' EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R13
Soprerna, Inc. Revision 11:10/06/2017
Page 7 of 8
QTRINITYIERD
8. MANUFACTURING PLANTS: .
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant, _,
Specification
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-N, Lastobond Pro HT-S, Lastobond 195, Lastobond
Drummondville,
ASTM D1970
Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth Seal HT,
QC (Canada)
RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector,
RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Colphene FIR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Lastobond TU HT; Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Gulfport, MS
ASTM D1970'
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate ojAuthorization #9503
i
Evaluation Report S18010.06.09-Ril
d'H EDITION.(2017) FBC NON-HVHZ EVAWATION FL2569-R13
Soprema, Inc. Revision 11:10/06/2017
Page 8 of 8