Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING2/13/2018 Florida B611clinq Code Online BY BCIS Home i Log In User Registration j Hot Topics j Submit Surcharge ( Stats & Facts l Publications �i. FBC Staff .I< BCIS Site Map I Links ( Search Florida Product Approval Q USER: Public User Product Approval Menu > Product or Application Search > Application List Application Detail FL # FL2037E Application Type Revision I Code Version 2017 i Application Status Approve Comments Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flva[lidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palle City, FL 34990 (772) 872-8034 nchard@emfab.net Quality Assurance Representative Address/Phone/Email Category I Roofing Subcategory MetaI Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Gl Validation Checklist - Hardcopy Received i Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 I https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5I,CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 1/4 Ii 2/13/2018 _ Florida Building Code Online I I Product Approval Method Method 1 Option D i Date Submitted 08/18/2017 Date Validated 112/18/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/19/2017 I _ Summary of Products i FL # Model, Number or Name Description 20378.1 01 - "1" Nailstrip" 0.032" Aluminum Standing Seam roof panel, 12" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.1 NAILSTRIP 1.0_.032 Approved for use outside HVHZ: Yes ALUM _sss.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and i Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378_R1_AE_FL 20378.1 NAILSTRIP 1.0 .032 instructions. ALUM_sss.pdf Created by Independent Third Party: Yes 20378.2 02 - "1" Nailstrip" 26-gauge Steel Standing Seam roof panel, 16" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners and adhesive. Limits of Use j Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.2 Extreme Metal Fabricators_ 26GA NAIL STRIP 1.0.121 Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378_Rl_A_E_FL 20378.2 Extreme Metal Fabricators 26GA NAIL STRIP 1.O.pdf instructions. Created by Independent Third Party: Yes 20378.3 03 - "1.75 Snap Lock" 0.032" Aluminum Standing Seam roof panel, 18" wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_Rl_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A ! Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Created by Independent Third Party: Yes Conditions of Use. Refer to manufacturer's installation instructions. 20378.4 04 - "1.75" Snap Lock" 24-gauge Steel Standing Seam roof panel, 18" wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No I FL20378_R1_II_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_Rl_AE_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf Created by Independent Third Party: Yes Conditions of Use. Refer to manufacturer's installation instructions. 20378.5 05 - "Rib Panel" 29-gauge Steel exposed fastener roof panel, 36" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.5 RIB 29GA ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Evaluation Reports Other: Refer to evaluation report for Limitations and i FL20378_R1_AE_FL 20378.5 RIB 29GA_ssr.pdf Conditions of Use.. Refer to manufacturer's installation l Created by Independent Third Party: Yes instructions. I I https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 2/4 i 2/13/2018 i Florida Building Code Online 20378.6 06 - "5V Crimp" I 26-gauge Steel exposed fastener roof panel, 24" wide, I mechanically attached to' 15/32" Plywood or Wood Deck w/fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No I FL20378_RI_II_FL 20378.6_5V Crimp_sss.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Method 1 and Method 2 FL20378_R3_AE_FL 20378.6_ V Crim __ssr.pdf fastening. Limitations and Conditions of Use. Refer to 'I Created by Independent Third Party: Yes manufacturer's installation instructions. 20378.7 07 - "1.5 Standing Seam" I 24-gauge Steel Standing Seam roof panel, 16" wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips, fasteners and adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.7 IM STANDING SEAM_ssr.p_df, Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.7 JM STANDING SEAM ssr.odf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 20378.8 08 - "Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.8 NORDMAN TILE 24GA_ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No -Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.8_NORDMAN TILE 24GA ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 20378.9 109 - "Nordman Tile" ( 24-gauge Steel metal roof tile panel mechanically attached to Steel Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.9 Nordman Tile Details-ssr.odf Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: +N/A/ -Table A i Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378_RI_AE_FL 20378.9 Nordman Tile Details-ssr.odf instructions. Created by Independent Third Party: Yes 20378.10 110 - "Nordman Tile" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for Limitations and Conditions of Use. Refer to manufacturer's installatior instructions. 0.032" Aluminum metal roof tile panel mechanically attached to 15/32" plywood or Wood Deck with fasteners. Installation Instructions FL20378_R1_II_FL 20378.10 NORD TILT .032 ALUM-ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL20378 R1 AE FL 20378.10 NORD TILT .032 ALUM-ssr.odf Created by Independent Third Party: Yes F;iac3c next I Ii Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . I Product Approval Accepts: aChacT Credit Card Safe https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa°/a2fE%2fovztglbhDVU2dJO4TAA%3d%3d 3/4 Compliant with Florida Building Code 2017 (61" ed.) Compliant with Florida Product Approval Rule #;61G20-3 Compliant: Keystone Certifications j Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec.1507.4.2 Yield strength: 40ksi Attached to Wood Deck with screws. 16" Coverage Corrosion Resistant Compliant: FBC Sec.1507.4.1,, Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate 3/16" thru 15/32" min. plywood deck I Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive along male flange the full length of panel. ` Underlayment: To be compliant with FBC Sec. 15017 Slope: Shall be in compliance with FBC Sec. 1507.. 1.1 Install Details: Table_A Allowable Loads ; METHOD1mainfieid METHOD perimeter DESIGN PRESSURE -69.25 PSF 121.75 PSF w FASTENER SPACING -ALONG ROWS., .. 1 -6" O.C. 6" O.C. FASTENER SIZE: #10 #10 ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to Reference Data:; HURRICANE TEST LABORATORY, L.L.C. #TST ID: 1527 Report #:0223-0313-02 TAS125-03(UL 580-061UL 1897-041) R,eport#: 0223-1015-06 TAS125-03(UL 580-06/UL 1897-041) EQUIVALENCY: UL 1897-04 /S EQUIVALENT TO UL 1897-12 TEST STANDARD *.DESIGN PRESSURE MARGIN:OF SAFETY2: 9 Certificate of Independence: � Locke Bowden, P.E. does not have, not will acquire a financial interest i!Nint'�b— oariy manufacturing or distributing products under this evaluation. ��R. �CC✓�t (,:.��� Locke Bowden, P.E. is not owned, operated, or controlled by any VhVany',rjAq tteRu e�, &distributing products under this report. ; a •� r— i FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other -registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22, for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended', product use outside of this report. i OWwto Table "Al Seam Adhesive Apply 318" bead Bostik Sealant entire length of panel along male flange #lox I" • Pancake Head Screwy