FL # FL2037E
Application Type Revision
I
Code Version 2017
i
Application Status Approve
Comments
Archived
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature
Richard McKuhen
flva[lidation@yahoo.com
Technical Representative
Richard McKuhen
Address/Phone/Email
2160 SW Poma Drive
Palle City, FL 34990
(772) 872-8034
nchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category
I
Roofing
Subcategory
MetaI Roofing
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/22/2024
Validated By
Zachary R. Priest, P.E.
Gl Validation Checklist - Hardcopy Received
i
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Standard
Year
TAS 125
2003
UL1897
2012
UL 580
2006
I
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5I,CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 1/4
Ii
2/13/2018 _ Florida Building Code Online
I
I
Product Approval Method Method 1 Option D
i
Date Submitted 08/18/2017
Date Validated 112/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
I
_
Summary of Products
i
FL #
Model, Number or Name
Description
20378.1
01 - "1" Nailstrip"
0.032" Aluminum Standing Seam roof panel, 12" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_R1_II_FL 20378.1 NAILSTRIP 1.0_.032
Approved for use outside HVHZ: Yes
ALUM _sss.pdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and i
Evaluation Reports
Conditions of Use. Refer to manufacturer's installation
FL20378_R1_AE_FL 20378.1 NAILSTRIP 1.0 .032
instructions.
ALUM_sss.pdf
Created by Independent Third Party: Yes
20378.2
02 - "1" Nailstrip"
26-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners and adhesive.
Limits of Use j
Installation Instructions
Approved for use in HVHZ: No
FL20378_R1_II_FL 20378.2 Extreme Metal Fabricators_ 26GA
NAIL STRIP 1.0.121
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and
Evaluation Reports
Conditions of Use. Refer to manufacturer's installation
FL20378_Rl_A_E_FL 20378.2 Extreme Metal Fabricators
26GA NAIL STRIP 1.O.pdf
instructions.
Created by Independent Third Party: Yes
20378.3
03 - "1.75 Snap Lock"
0.032" Aluminum Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_Rl_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A !
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Created by Independent Third Party: Yes
Conditions of Use. Refer to manufacturer's installation
instructions.
20378.4
04 - "1.75" Snap Lock"
24-gauge Steel Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No I
FL20378_R1_II_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_Rl_AE_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf
Created by Independent Third Party: Yes
Conditions of Use. Refer to manufacturer's installation
instructions.
20378.5
05 - "Rib Panel"
29-gauge Steel exposed fastener roof panel, 36" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_R1_II_FL 20378.5 RIB 29GA ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A I
Evaluation Reports
Other: Refer to evaluation report for Limitations and i
FL20378_R1_AE_FL 20378.5 RIB 29GA_ssr.pdf
Conditions of Use.. Refer to manufacturer's installation l
Created by Independent Third Party: Yes
instructions.
I
I
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 2/4
i
2/13/2018 i Florida Building Code Online
20378.6 06 - "5V Crimp" I 26-gauge Steel exposed fastener roof panel, 24" wide,
I mechanically attached to' 15/32" Plywood or Wood Deck
w/fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No I FL20378_RI_II_FL 20378.6_5V Crimp_sss.pdf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for Method 1 and Method 2 FL20378_R3_AE_FL 20378.6_ V Crim __ssr.pdf
fastening. Limitations and Conditions of Use. Refer to 'I Created by Independent Third Party: Yes
manufacturer's installation instructions.
20378.7
07 - "1.5 Standing Seam" I
24-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips, fasteners and adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_R1_II_FL 20378.7 IM STANDING SEAM_ssr.p_df,
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A I
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_R1_AE_FL 20378.7 JM STANDING SEAM ssr.odf
Conditions of Use. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
20378.8 08 - "Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
15/32" plywood or Wood Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.8 NORDMAN TILE 24GA_ssr.pdf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No -Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.8_NORDMAN TILE 24GA ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.9 109 - "Nordman Tile" ( 24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.9 Nordman Tile Details-ssr.odf
Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E.
Impact Resistant: No #31242
Design Pressure: +N/A/ -Table A i Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_RI_AE_FL 20378.9 Nordman Tile Details-ssr.odf
instructions. Created by Independent Third Party: Yes
20378.10 110 - "Nordman Tile"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer's installatior
instructions.
0.032" Aluminum metal roof tile panel mechanically attached
to 15/32" plywood or Wood Deck with fasteners.
Installation Instructions
FL20378_R1_II_FL 20378.10 NORD TILT .032 ALUM-ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL20378 R1 AE FL 20378.10 NORD TILT .032 ALUM-ssr.odf
Created by Independent Third Party: Yes
F;iac3c next
I
Ii
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
I
Product Approval Accepts:
aChacT
Credit Card
Safe
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa°/a2fE%2fovztglbhDVU2dJO4TAA%3d%3d 3/4
Compliant with Florida Building Code 2017 (61" ed.)
Compliant with Florida Product Approval Rule #;61G20-3
Compliant: Keystone Certifications j
Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec.1507.4.2
Yield strength: 40ksi Attached to Wood Deck with screws.
16" Coverage
Corrosion Resistant Compliant: FBC Sec.1507.4.1,,
Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate
3/16" thru 15/32" min. plywood deck I
Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive
along male flange the full length of panel. `
Underlayment: To be compliant with FBC Sec. 15017
Slope: Shall be in compliance with FBC Sec. 1507.. 1.1
Install Details: Table_A Allowable Loads ; METHOD1mainfieid METHOD perimeter
DESIGN PRESSURE -69.25 PSF 121.75 PSF w
FASTENER SPACING -ALONG ROWS., .. 1 -6" O.C. 6" O.C.
FASTENER SIZE: #10 #10
ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to
Reference Data:; HURRICANE TEST LABORATORY, L.L.C. #TST ID: 1527
Report #:0223-0313-02 TAS125-03(UL 580-061UL 1897-041)
R,eport#: 0223-1015-06 TAS125-03(UL 580-06/UL 1897-041)
EQUIVALENCY: UL 1897-04 /S EQUIVALENT TO UL 1897-12 TEST STANDARD *.DESIGN PRESSURE MARGIN:OF SAFETY2: 9
Certificate of Independence: �
Locke Bowden, P.E. does not have, not will acquire a financial interest i!Nint'�b— oariy manufacturing or distributing products
under this evaluation. ��R. �CC✓�t (,:.���
Locke Bowden, P.E. is not owned, operated, or controlled by any VhVany',rjAq tteRu e�, &distributing products under this
report. ; a •�
r—
i
FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed..
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other -registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22, for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended', product use outside of this report.
i OWwto Table "Al
Seam Adhesive
Apply 318" bead Bostik Sealant
entire length of panel
along male flange
#lox I"
• Pancake Head Screwy