Loading...
HomeMy WebLinkAboutBUILDING PLANt�ji . 00 .. W � J W Q J () W � FHV $' IN GAB 141UP&DN Ix f Y , 1 I 1-1 4 B / .-J r 1 .A 4 - o Tjl� r i. l77 r L .:.-.... Fri 1. .� 1 I , 4 1f " FHv—' - JP R DN AL FLOOR FIRE PROTECTION PLAN SCALE: 1/8" = 1'-0" _ GBR PENDANT r4-TN ORIFICE - 1/2" NPT 55 GBR 16' X 20' 1/2" ORIFICE - 1/2' NPT 155 QRAAW • PT. PEWLE • W. PALbWACH 427 CERTERPRITE MCLE SUITE 1825• ALTANONTE SP WM FLOWA 32701 (407) 332-5110 FAX (407) 332-7704 131 K 2R0 ST., WTE 206. FT. PERCL FLUMA MW (407) 465-1165 FAX (407) 466-1164 2667 FOREST MLLS BLVD., SUITE 225. TEST PAIL BEACN. FLOWA 3340E (407) 963-M FAX (407) 434-7745 6 REVISIONS o C(1PYRRO FF 20f DOIJULAS R(R)'I' AROIII Al A. RRill IS RI:SI'R5 DRAWN J.L.S. C111?CK1(D A.K. UA"11;. 02/01/0 SCALE AS NOTE( )011 No SIIEP.T �20 uE ASSOCIATES INC. I REVISIONS I i I 4� r carve a Ur a11111 INNAi,ASk nuf1III P4'iti. Ali RK IS Rf Sl N%IUI. 0 GB PENDANT 1/2" ORIFICE - GBR16'x20' 112" ORIFICE - PENTHOUSE FIRE PROTECTION PLAN SCALE: 1/8" = 1'-0" _ CALAAW " FT. P99WLE • W. P"MACH 427 CENTERPMTE OA117F, BATE IM ALTAN wM SPR9RS. FLORIDA 32701 (401) 332-5110 FAX (407) S32-7704 131 It 2N0 St. SALE 206. FT. PFROL FLORIDA 3" (417) 456--1165 FAX: (407) 466-1164 2689 FOREST R41S RLVD., SATE 225. SST PAW REAM, FLORIDA 334NI (407) 963-9600 FAX (407) 431 n45 In So o �Q W) rn ON r o ,O M M �O So So N h z U LJ O 0 �- z �U z W V) I- - z Q Q = a U LLI -D DQ O uLLJ U Q DRAWN J. L. S. (IIECKFO A.K. I)ATE. 02/01/01 SCALP. AS NOTED JOB NO. SIITT F-203 OP SIIICISIti ASSOCIATES INC. STANDPIPE EXPOSED WILL BE GALV 1 WATER PRESSURE GAUGE 2 1/2" FIRE DEPARTMENT HOSE VALVE CAP AND CHAIN @6'-0"- 12TH FLOOR 8'-11" AFF 2 1/2" FIRE DEPARTMENT HOSE VALVE CAP AND CHAIN 05'-0" 2ND-11TH FLOOR 7'-10" AFF 4 6" 2 1/2" FIRE DEPARTMENT HOSE VALVE CAP AND CHAIN 05'-0"- 1ST FLOOR 9'-6" AFF W o a O 1n (ff) O Q J STANDPIPE DETAIL N TS / I , I I I I 1 1 �- ..- ------ -_.. .----- I .. \f MANIFOLD _ I i I - I I , F I I V .' -- -- __.�... --- - ---------- J i B C:1 \ I / I I 1 i , IF- - - � r r II I I I I I ' I I 1 I 1 I I I I I I 1 I 1 I \ I , I 1 / � I /, �ItVgf I I(!lSSJJ I l I I \ � I ' I -- ---/ - j PLUMBING ROOF PLAN SCALE: 1/8" = 1'-0" _ O GEI PENDANT % 1/2- ORIFICE - 1/2- NPT t55 COAL L / M EIVOYEE 717 CALA1111130 ° FT. PH91GF • W. P"EEApY 421 CEFITERPONTE CIRCLE, 4111E 1625, ALTAMONTE WRINGS. FLORIDA 32701 (407) 332-5110 FAIL (401) 332-7704 131 K M ST., SLATE 206. FT. PERCE. FLORIDA 549" (407) 456-1155 FAX (407) 06-1164 2969 FOREST HILLS BLVD.. SLATE 225, REST PAW BEACH, FLORpA 33(OG (407) 961-9900 FAA: (407) 434-7745 ASSOCIATE! INC. REVISIONS O ('OPYRRIIFF 201II) INIII(R.AS R1R)T TA ARQIRI-13. All. kit II i'1'S REFER VIA). z U5 Li 0 0�— z �ULd z z EL UU r 0Q w 0 ~ c� Q DRAWN J.L.S. CI1FCKI40 A.K. OA IT 02/01/01 SCALE. AS NOTED JOB NO. SIM17 F204 OF sill"T Fs Q 10_o- 350CFM 8XB-4W ,y'L\ I VD ;' 150CFM VD 8"I a 30X12-EL I I I , 1 ! I I 8X8 A�YY I I51 1 n IF,150CFIA I I I � I i 1 8xe-4w Tm � - 150CFM 402-OAL 1912 i. axa 4w) 15OCFM 1 j �1BX18 DG VD AC 4 t FD FD I 44 14 18X18 DG VD llG� ,a *lLr1P1^f,,. - (S 48X30-RG o 36X30 OA ii 48/14 P II --- T FD, EMERGENCY 60X84-EL 2"CW IR R UP GENERATOR i � ! 10/6 T � ----------- 8X8-RG 18X126-OAL T f--1 w FD loocim 10/6 $.0 1W 10/8 18X18-DC 150CFM 24X16-EL 12/8 ,ox10-TG 18X18DG` FD 10"0_1 W �'�'� 300CF1d 12r8 SSF-1 WEATHER HOOD 54 24 / 150" 15DOOCFM 150CFM _ LE--1 --) 1-1/2"CWS&R .,^ ( ( - toxa_sw " - 10'(O0CIF.M 150C ,' I FD ...I 1. _) 10 0-4W 350CFM I 0 1070-4 350CFM 1 ' 10 5 32CFM / � 1 I I 1 10 0 14"0-4HI 1Il"0=4.IY 26/14 24/14 26/12 \ "CW'S 1 20X8-SW 20X8-SLl 400CFM I 400CFM ,- 20XB-SW 20X8 SW 400CFM' 400CFM .7 I ; ` I I I - -- _ 24X8 - 45M II 4!)OCFM zz I- I, I I I I I I I I I I I I I I I I 17 I \,' 'y I 1 !A I I I I I I � i I `•,..�i I+ 1 1 I / I I I I 1 I I I I I I I I I I I c:1 --------------------- FIRST FLOO M.A.C. PLAN_ SCALE: 1/8" = 1'-0" _ 275CFM 300CFM I I I I I I 26/12 I I I I 1 I N 10 0_4W V24'X12-OAL 300CFM 0 5 FM R J I I 1 � \ i UP 1 _ � 00 _ - 325CF25CF M 1070-491 300CFM U / � 1 t- I VD 1 19__0-4W 10"o- 250CFM 35OCFM I I N I I a I I I A! I 10.-0-4W 10 0-4W 1�-- 350CFM 350CFM 12x12 0PL I I I ------•---- CABANA HY.A.C. PLAN SCALE: 1/4" = 1'-0" COAGM7M EnGPJEEM MASSOCIATCS �AWO • FT,PERW - W.PAW6EAp1 427 (INTS"TE CRCA, SATE IM ALTMONIE 7PFAM ROMA 32701 (407) 332-5110 FAX (407) 332-7704 131 N. 21D ST., S1A1F 206. FT. PIFACL FLOINA .34W (407) 465-1165 FAIL (407) 466-1164 2M FORM NILS BLVD., SATE 225. REST PALM BEAIN, RORDA 334W (407) K. -"W FAX (407) 434-7745 REVISIONS IJ (Y)PYRR81'120W I HIGLAN R(N91' AROIT11'7IS. AI J. R IGI ffS RPSITR VI']. z 0 � w 0 0 o� z fyULLJ z (n F- z Q= �v W �r o < W Q U Q DRAWN J.L.S. CI IP.C1K14) A.K. DATE. 02/01/01 SCALE. AS NOTED JOI3 NO M201 OF SI IIiF`I:S II RIIVISIUNS 2 2 M301 M301 F ..=ff =..... t_j - ,,� � 7 Ji hI ' C �♦ 00, I CWS AND CWR RISERS / n uU� REFER TO CONDENSER WATER , ' RISER DIAGRAM ON SHEET M401 FOR SIZLS 0 q I , I ,CWS AND CWR W RISERS - REFER TO CONDENS REFER TO {jj{jr--AA ;i RISER DIAGRAM ON SHEET �171 M401 FOR SIZES % M301KFD i 1 1 I j _ �--_elf=-------��: I n TYPICAL FLOOR H.V.A.C. PLAN SCALE: 1/6 = 1'-0" - r, k,. �I CWS AND CWR RISERS REFER 10 CONDENSER WAR $'SER DIAGRAM ON SHEET M301 M401 FOR SIZES I 0 COAGUL S"ZEM q%AAM • FT. PARX - W. PAW BEWH 421 OENTE7II(SNTE ORcLL Sf1E 1925. ALTA O(TE SPRINGS FLORIDA 32701 (407) 332-5110 FAX (401) 337-7704 ` 131 R, M ST., SUTE 2M FT. PFRCE TIARDA 3400 (407) W-1165 FATE (407) 41, ne( Aft FOREST RUS BLVD.. WIE 22S JEST P" PFAOI. ROIIDA 33406 ASSOCIATES (407) 9E3-M FAX (407) 431-IM INC. O CIIPVR Kii ❑' 21MM1 D(111(i1.Ati RIK)F AN("IIO'IA'IS. AI.1. RKiI(I S RI SF.RVRD. z �- o O O �— z ryU z z UU W LJ OQ Q F U Q DRAWN J.L.S. ('11ECKE) A.K. DATE 02/01/01 SCA I,E AS NOTED JOB NO. SIIF.ET M 2 0 2 Q 4'CWS&R (T9I$'FWW ♦1 L CWS AND CWR RISERS 1 REFER TO CONDENSER WATE 1 RISER DIAGRAM ON SHEET 3 y M401 FOR SIZES M302)1 6OX18-EC 1 i114Y1R-Ff. ♦_1L'c1r�== J -------------u -- 0 0 2 2 M302 M302 Dt 4 III 1 n 4 PENTHOUSE FL D 1 1 CWS ,AND CWR RISERS REFER TO CONDENSER WATER 1 RISER DIAGRAM ON SHEET M401 FOR SIZES H.V.A.C. PLAN SCALE: 1/8" = 1'-0. _ "CWS&R (TOP FLOOR ONLY) ma�y'I CWS AND CWR RISERS 1 _REFER TO CONDENSER WATER E RISER DIAGRAM ON SHEET ��-- f-- M401 FOR SIZES C.AK AADO • PT. PE97CE - W. PAW S5i1CH *27 CENFfOpOINTE CIRCLE, SUNS 1825, AETA"IE SRHINC;, FLORIDA 32701 (407) 332-5110 FAX: (407) 332-T104 III N 2ND ST„ STATE 208, FT. REKE, FLORIDA 34W (407) 466 FAX: (W) 466-1464 2669 FORT ST HILLS BLVD, W1F 725, HEST PALM BEACH, FLORIDA 3340 (401) 963-9600 FAX (407) 434-7745 RE.V ISIONS onrevaanu2lrn f14111(N AS Rm F ARCIi Ff RA7S. AU RRiIl FS RIISVRVEl). z � (/71 z 0 OF-- z CIO,U z LLJ z Q= CD w �ry ::D ~ Q v LLB U Q DRAWN J. L. S. III( kill A.K. DAn. 02/01/01 S('AI-E AS NOTED JOB NO. In Ao o rn N o ALJ 4'•1 V, I Q 0 O w 8 If OF SNF•,E•,'rs ASSOCIATES WC. JA 4 DRYER EF W:-1 i 1; 1 BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF CLEAN OUT (TYP.) BATH EF DRYER TYPICAL TOILET TOILET El TOILET EF BATH EF BATH EF BATH EF BATH EF �W N U F C w BATH EF 0, W BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF BATH EF ROOF 12TH FLC 11TH 10TH r'�1i1 8TH FLC 7TH FLC 6TH 5TH FL( 4TH 3RD FL 2ND FL DRYER EXHAUST RISER DIAGRAMS ( u i I ' w FF-16 PT Y. . 7-1 J � 1 , -3 1 r � % I I 4"(,WS&R LN 1/4"cw5&R, ;ff --T/a'cws&R I "^T7Y;--�IQL^,7IIIIIIIIfS1IilIIDITI7IIIIIItIl 8/1 r 8/1 AC C t _ L._ _. U _.. . CT-1Ff it YCW 6'CWS 4'CWS&R 4"CWS&R [4oCWS&R ON I Cws CWR D' -IKI 1_,._ 6'CWS Wi 1 EULU ----- T _ � F I 9� _B 0 ill- s� FDJ_ SD_' � ,. lll'1L11CIe1 � I WS&R LE& DISCHARGE AT 40' I ABOVE ROOF zi --. 32X32-EL2 I -r-' _ DGFM _-_--.------ - - H.V.A.C. ROOF PLAN SCALE: 118" = 1'-0" _ NOTE: REFER TO TOWER RISER DIAGRAM ON SHEET M401 FOR TOWER PIPING SCHEMATIC AND SIZES. oomm7M 411 CENRVMTE CVQL WEE 1825. ALIAMONIE SPRMCS, FLOWA 32701 (407) 332-511D FAX (407) 332-7704 131 & 2FD St. SAME 205. FT. PUM FLORIDA 34916 (407) 456-1103 FAX (107) 455-1164 266V FOREST HLLS BLVD., SUTE 225. VEST PALL BEACH, RDPoDA 33" (407) 18.3-1600 FAX (407) 434-7745 RF.VISIONS 1)(1OPVRRIIf I21MA) DUI RII AS R(X)1' ARf1I IF1'ICIS. AI k RIGII'I'S A)iSFR VITI. o �o �, rn z � ( I m � F— C) 0 z a z UU c Qo OQ w "u o w U � S L� Q 11 �i ua Q DRAWN J.L.S. ('11F.CKF.D A.K. DA'ITI 02/01/01 S('ALF. AS NOTED ]OD NO. SHEET M204 OF Slllll: Iti 4TES INC. { EF UZ 8X6-sw 1QX6_SW 125CFM (175CFM) fr, Q 16X8-SW 350CFM I (400CFM) a { I 8X6-SW 125CFM =14/8 EX 4"0-1W 4"0 25CFM _ \ I. L I ' 250CFM " -- ') 300CFM � ' ( ) 4" 0-1W k" !� /r 00 25CFM �. ---- 00 4"0 0 4 0 Ulcp 6"0- \0� 50CFM - - i 6"0 \ , \ I I Tr,_. n �I 4"0-2W _ 30GFM NS 40 14X8-SW � , 270CFM 1 14/8 00 30Xi8-RG 6"000 100CFM RE Irl - r J -- - - 12X6-SW1 150CFM 18/12 EXHAUST RISER ( w ) 4"(0 1 EF-U1 E- -6- - - 4"0- 8"0 I { 25CFM 12K6-SW 150CFM I v NOTE; AIRFLOW VALUES IN PARENTHESES INDICATE UNIT D AIRFLOWS HY.A.C. FLOORPLAN'- UNITS AD (TYPICAL FLOOR) (UNIT D MIRROR IMAGE) SCALE: 1/4" = 1'-0" IJLI\I ■ EVEN DCT RISER — 4"0 DR R VENT I■ ■ 1 F kl� ■ ■ ■ ■ I H I BX6-SW 108-SW 100CFM 300CFM 6.0 re . � I � ky kkL.A♦ i 1 XO 6_SW 150CFM a E_ 1 -14/12 EXHAUST RISER 4"0 4"0-1 W 25CFM EF U1 4 0 lava_cw I I; w !I III N 1 11 i. I rli r Ili I, yrfs� ' 6 li P lit I 14X8-SW 300CFM I 4°0-iW 25CFM 4"0-1 4"0 - 12/12 EXHAUST RISER 25CFM 4 0 \' 1T 8X6-SW 75CFM 7"0 140CFM 14/81EXHAUST RISER- H"V.A.C. FLOOR PLAN - UNITS B,C (TYPICAL FLOOR) (UNIT C MIRROR IMAGE) SCALE: 1/4" = 1'-0" 4 EF Ul e i 1 XO 6' SW 100CFM i� AC B (AC-C) 7I r - I IX I B 4 0 25CFM 4, 4"0 4"0 DRYER VENT 10/8 DRYER VENT RISER i COASEUM ENCOWFERS CbVAAEp • FT. PB#L'E • W. PAi,b96WH 427 CIRTMOINTE CRaE. SUR: 1825, ALTAMONTE SP NGS, FLORIDA 32701 (401) 332-5110 FAX- (407) 332-T704 131 K 21V ST.. STATE 20Q FT. PIERCE. FLORIDA 34M (407) 456-1165 FAX (407) 466-1164 2669 FOREST HE15 BL)D., SUTE 225. EST PALM BEACH, FLORIDA 33406 (407) 963-9600 FAX- (407) "-7745 REVISIONS O C(1PYRRKIT 2000 D(IIIGLAS R(R 1'F AR(11If1TCI5_ AI3. RI(il1 f} 11I4SERV10). z (n LLJ O 01— z (yULij z CIO z a Q = CL GO Li f— OQ o W Q 4 Q O W o A % U �D .a O F~ W d 'a z 0 � U [D x1 O H O z PRAWN J.L.S. ('I IP.('KED A.K. FAIT. 02/01/01 SCAE.F. AS NOTED JOTS NO SIIER M 301 (W SIIF.IIS ASAlt4 I 1oX6-SW 125CFM (175CFM) o i 1. 16X8_5W 8X—,125CFM 350CFM (400CFM) ;I ,I _ .. ---- ....--� 4" -1 25CFM 1 i i l i 14X8_SW 4"0 -- i. 2) i 250CFM — . ; (300CFM) 0_1W \` __ �', D 4 25CFM 14/8 4*0 66"0 4W � 50CFM 1 s' 6"0 108-SW - `y 270CFM (300CFM) C14` 3orlu 4" IT --_ 1 4"0 [[ LI U2 6"0 ` 8X6-SW L. 100CFM - r � I 4"0 - ' x 10 _ 1 Sw OCFM 18/12 EXHAUST RISER I ;� LE7 In rh /18 UP 11 OD L 4"0 I _� E 4"0 iW 14A 25CFM "o I _ r I 4"0 1 -U1 NOTE: AIRFLOW VALUES IN PARENTHESES INDICATE UNIT D AIRFLOWS HY.A.C. F GQRTLAN UNITS A D (TOP PENTHOUSE FLOOR) (UNIT D MIRROR IMAGE) SCALE: 1/4" = 1' O" �l/' p 1 � I p■ VEN DYCT RISER 4"0 AIR VENT 1 I 1 1 1 8X6-SW 14XB-SW 100CFM 300CFM 6"0 ♦ 14X8SW _,•, `� 225CFM �& 011/ ♦ 1 X -SW 150CFM � (l( 1 Do 14/12 EXHAUST RISER lz 4"0 4i10 4"0-1 W �. 25CFM t [ iai F-U1 7"0 12X6-SW i AJ if II1 ph 11 f - llj i' IIi II' 0 III 108-SW 300CFM 1 T- r'"25CFM 40-1 � 4"0 \ 12/12 EXHAUST RISER R 25CFM 40 i (n � j L. r 4"0 4 EF-Ul 11 X�- _ _V 1'I 75CFM I 00 1� a 1 I ) 1oX6-S , t00CFM o ;1 1I � III 9I 1 'i.. 0=1W ( R FM 24 / ® II 8 /� 1 I I • I 18/18 UP - !- �I II • 4"0-1W ®4 0-1W 25CFM 25CFM 7"0 — 4"0 DRYER ;VENT 12X- 140CFM �i t 14/�' EXHAUST RISER 110/8 DRYER VENT 215ER 11 II, 1i1 II - II J.-_...._..._. i \ ( HN.A.C. FLOOR PLAN - UNITS B C (TOP PENIHOUSE FLOOR) (UNIT C MIRROR IMAGE) SCALE: 1/4" = 1'-0' CXXISM 7M EEW 0ALAADO • FT. PM9WE • W. P"EEACH 427 CENTERPODIE twOLL SATE 1625, ALTAMCHTE TRAM FLORIDA 32701 (407) 332-5110 FAX (407) 432-77U 131 N. 2N1 ST.• SUIE 206, FT. PIERCE. FLORIDA 34946 (407) 460-1165 FAX (407) 466-1184 2609 FOREST MIN BLM)., SLATE 225. WEST P" BEACH, FLORIDA SUN (41 963-•000 FAX (407) 434-7745 1 RP:VISIONS ll v c(IPVRR II rr 2000 DUII(II AS R( N)'r AR(111RFf'IS. A1A. MCI I rS RESERVED. Z V) Wp 0 f— z �U z Z Q UU W � OQ W 0 ~ C� cr- Q Q ~� 0O DRAWN J.L.S. A.K. DATF 02/01/01 S(Alk.. AS NOTED JOB NO. SIIIifT M 302 OF surR S O TES INC. H F V) CD I 1 COOLING TOWER CT-1 BY-PASS 6 P-1 6" 6" P-2 6" CHEMICAL SHOT FEEDER -- 4" 1. AC-7 4" INTEGRAL PUMP 4" HIGH CAPACITY - AIR SEPARATOR AUTOMATIC AIR VENT ASO-1 01 c m. AC -A 1-1/2" AC B ROOF AC-5 4" 12TH 4" 4" 11TH AC -A 1-1/4" 4" AC B 4" 10TH AC -A 1-1/4" 4" AC B 9TH 4" AC -A 1-1/4" 4" AC B 3" 8TH AC -A 1-i/4"- 3" AC B — 3" 7TH AC -A 1-1/4" 3" AC B 6TH 3" AC -A 1-1/4" 3" AC B 5TH AC -A 1-1/4" 2-1/2" AC B 2-1/2" / 4TH AC -A 1-1/4" 2-1/2' 2-1/2" AC B / " 2-1/2" 3RD AC -A 1-1/4 2-1/2" AC B 2ND 2" AC -A 1-1/4" 2" AC B 1ST AC-4 AC-3 1-1/4" 4" 4" 6" 6" u -1/4" AC-C I 4" 4" 1-1/4" AC-C 4" 4" 1-1/4" AC-C ' 1 4" 4" i-1/4" AC-C 4" 4" 1-1/4" AC-C AC-C 7/77A AC-C AC-C - 3" 1-1/4" AC-C r 3" — 2" I 2" 1-1/4" AC-C -1-1/4" AC-C TOWER WATER RISER DIAGRAM, N TS 4" 4" AC 0 1-1/2" — 4" i., AC-8 4" AC-6 2-1/2" — 4" 4" 12TH 4" ri AC- D /4" 4" 11TH - 4" AC- D 1-1/4" — 4" 1OTH 4" AC-D 1-1/4" 4" 9TH 3" AC- D i-1/4" -- 3" 8TH 3" AC-D 1-1/4" ___ 3" 7TH 3" AC-D 1-1/4"- 3" 6TH AC D 2-1/2" 2-1/2" 5TH 1-1/4"- AC-D 2-1/2" 2 1/2" 4TH 1-1/4" 2" AC-D 1-1/4" 2" 3RD AC-D 1-1/2" 2ND 1-1/4" AC-2 AC-1 1ST 7M EnKMEBW pLAKaO " FT PErm " W. PALM aEil H 427 CDIIFAPME CAICIE. SATE 1625, ALTAMONTE %R*gr, FLOADA 32MI (407) 3]2-5110 FAY- (407) 332-7704 131 lA 2ND ST., SAIE 206, FT. PEACE, FLOIIDA 34M (407) 466-1165 FAX (407) 466-1164 2002 FOAFST HILLS BLVD.. SATE 225, HEST PAIAI SEADI, 1109DA :SN06 (407) 963-9600 FAX (407) 4 1745 Z 0 p O O,- z rU z W z Q Q �U Ld �r OQ W 0 ~ u Q DRAWN J.L.S. ('I I I'.CKED A.K. DA T 02/01/01 SCAT. AS NOTED JOB NO M401 OF SIIIII:PS d FLEXIBLE DUCT TO 16 GA. GALVANIZED D AIR OUTLET. BLADE, 1/4" LESS THAN DUCT DIA. UTILIZE STAINLESS STEEL WORM DRIVEN CLAMPS AND U.L. APPROVED MASTIC SEALANT FOR ATTACHING 3/8" SQUARE ROD FLEXIBLE DUCT TO CLINCH COLLAR. END BEARING LOCKING TYPE QUADRANT — OPERATORVINDICATOR WITH 2" MAIN DUCT STAND-OFF — - SPIN -IN FITTING AIR FLOW SPIN —IN BRANCH CONNECTION TO SINGLE AIR OUTLET NTS 1/3" W, 6" MIN. DAMPER SUPPLY AIR DUCT STY ARt vLaO RENRN AIR ROW F d 'a BRANCH DUCT_ W METAL STRAP 1-1/2" MINIMUM SUPPORTS DUCT WITH SPLITTER DAMPER AT SINGLE BRANCH NTS 4'-0" MAXIMUM METAL STRAP IMUM SAG 1/2" PER FOOT 1-1/2" MINIMI SUPPORT SPACING. - FLEXIBLE DUCT NOTES: 1. DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. 2. SUPPORT SYSTEM MUST NOT DAMAGE DU T OR CAUSE OUT OF ROUND SHAPE. FLEX DUCI SUPPORT DRAIN PAN TOTAL STATIC PRESSURE "+1" (MINIMUM 4") EXTEND PIPE 2" ABOVE CENTER, SIZE EQUAL TO DRAIN PAN CONNECTION, FOR VENTING MIN. W PER FOOT SLOPE LINE SIZE EQUAL TO DRAIN PAN CONNECTION, ROUTE AS INDICATED OR AS INDICATED ON DRAWINGS 4" MIN. CENTER TO CENTER OR 1-1/2 TIMES UNIT STATIC PRESSURE GATE VALVE ASME RELIEF VALVE, PIPE 14"? FLUE WITH WEATHER CAP TO FLOOR DRAIN BOILER THERMOMETER PILOT SOLENOID VALVE GATE VALVE PILOT GAS PRESSURE REGULATOR KPRE SSURE GUAGE PILOT SHUT-OFF VALVEURNER HEAD INCOMING GAS LINE 01-1 MANUAL GAS SHUT-OFF VALVE GATE VALVE UNION LOW WATER CUT OFF GAS PRESSURE REGULATOR PIPE TO FLOOR DRAIN MOTORIZED AUTOMATIC GAS VALVE BURNER CONTROLS LEAK TEST VALVE BUTTERFLY GAS VALVE WITH BLOW DOWN DRAIN AND VALVE, LINKAGE TO FIRING RATE MOTOR PIPE TO FLOOR DRAIN 6" CONCRETE PAD, OVERLAP UNIT BY 6" ON ALL SIDES NOTE: UNIT SHALL BE FACTORY ASSEMBLED SUITABLE FOR OUTDOOR & SEACOAST INSTALLATION NTH ALL CONTROLS AND VITAL PARTS UNDER WEATHER HOOD. BOILER PIPING SCHEMATIC NTS NTS COOLING COIL SOLDERED TEE COPPER PIPE TYPE "M" OR PVC 8"MIN. CENTER TO CENTER OR 3 TIMES UNIT STATIC PRESSURE CONDENSATE DRAIN DETAIL SEAL ALL AROUND ROOF EXHAUST DUCT NTS ROOF MOUNTED EXHAUST FAN BIRDSCREEN REFABIRCATED ROOF CURB GRAVITY BACKDRAFT DAMPER TYPICIAL ROOF MOUNTED EXHAUST FAN NTS I RIGID SUPPLY DUCTWORK FLEX DUCT MIN. 6'-0" MAX. 8'-0" / LENGTH UTILIZE STAINLESS STEEL WORM DRIVEN CLAMPS AND U.L APPROVED MASTIC SEALANT FOR ATTACHING FLEXIBLE DUCT TO CUNCH COLLAR. NOTE: INSULATE BACK OF DIFFUSER. — DIFFUSER CEILING DIFFUSER AND FLEX DUCT DETAIL NTS MANUAL AIR ELIMINATOR GAGE COCK (TYP.) CIRCUIT SETTER BALANCE VALVE SHUT-OFF VALVE (TYP.) CONDENSER COIL WATER CONNECTION DETAIL FILL FUNNEL WITH COVER MANUAL AIR VENT 1 1/2 TO 2 GALLON FEEDER, HOT -DIP GALVANIZED DRAIN VALVE PIPE TO FLOOR DRAIN BALL VALVE (TYP.) UNION (TYP.) PUMP DISCHARGE LINE ARROW INDICATES DIRECTION OF FLOW (TYP.) r JMP SUCTION NE NTS CHEMICAL FEEDER DETAIL NTS CLOSE SWIVEL FITTING 1/4" 0 CLEARANCE SLIP SLEEVE WITH 2" STAND-OFF 1/4" 0 PUSH PULL ROD SUPPLY NO.16 GUAGE BLADE PIVOTS (TOP AND BOTTOM) 1/4" 0 SET SCREW LOCK NOTES: -ONE PULL ROD - DUCT DEPTH UP TO 24" -TWO PULL RODS - DUCT DEPTH 25" TO 36" -OVER 36" DUCT DEPTH USE VOLUME DAMPER ON EACH BRANCH DUCT WITH SPLITTER DAMPER NTS TO EXPANSION TANK AND COOLING TOWER CONNECTION UNION (TYP.) 2" PIPE TO DOMESTIC WATER FILL AND PRESSURE BACK FLOW PREVENTOR REDUCING VALVE GATE VALVE (TYP.) STRAINER NOTE: TYPICAL FOR COOLING CHECK VALVE GLOBE VALVE TOWER FILL LINE. MAKE—UP WATER PIPING DETAIL CHECK VALVE COUPLING GUARD BASE MOUNTED END SUC PUMP. SEE SCHEDULE INERTIA PAD . REFER TO ARCH. FOR CURB, AND STEEL SUPPORT DETAIL NTS BUTTERFLY VALVE SERVICE/SHUTOFF FLEXIBLE CONNECTION SUCTION DIFFUSER SEAL ALL PIPE PENETRATIONS SUPPORT BY MECH. CONTRACTOR ROOF SYSTEM. REFER TO ARCH, PUMP MOUNTING DETAIL NTS COARL 7M ENONSEW cm-mD�O a Pl. PBS • W. PALMEAC I 427 CTRTERPO*TE CRCLE, SURE ISM ALTAMOIIIE SPRNICS, FLORIDA 32701 (407) 332-5110 FAY, (407) 332-7704 131 R. 2D ST., SLATE 200, FT. PIFRM FIORAA 3400 (407) 466-1165 FAIL (407) 40-1164 2689 FOREST HRIS BUD., SURE 225, TEST PAW BEACH, ROMA M400 (407) 963-9600 FAIL (407) 43f 7745 REVISIONS O(1l IVV0.kllFf 201p RNII IGLAS 0.(M)'F ARCll FF19'IS. All Ithim S RI(SFRVPD. z 0 w 0 O O� z �ULLJ z (� I— z Q __j= UU w ct� O Q Iw 0 ~ Z EL' Q DRAWN J.L.S. CIIFb'KE.D A.K. DATE. 02/01/01 SCALP. AS NOTED JOB NO. SIIE•.P.T M5O1 OF SillICPS FAN SCHEDULE MARK SERVICE TYPE FAN MOTOR EQUAL TO NOTES CFM ESP IN, WC RPM DRIVE H.P. V/PH MFG. MODEL NO. 1ST FLR ELEC CEILING 150 0.5 1080 DIRECT 1DOW 120 1 LOREN COOK GC-420 1 3 7 EF-2 _ TRASH ROOM_ CEILING 400 0,375 1045 DIRECT 30OW 120 1 LOREN COOK GC-640 1 3 7 EF-3 PUMP ROOM CEILING 300 0.375 1150 DIRECT 20OW 120 1 LOREN COOK GC-520 1 3 7 EF-4 JANITOR CEILING 60 0.375 1130 DIRECT 5OW 120 1 LOREN COOK GC-140 1 2 7 EF-5 1ST FLOOR OILET CEILING 300 0.375 880 DIRECT 150W 120 1 LOREN COOK GC-620 1 2 7 EF-6 1ST FLOOR TOILETS CEILING 300 0.375 880 DIRECT 150W 120 1 LOREN COOK GC-620 4 7 8 EF-7_ UNIT A TOILET STACK ROOF CENT. 400 0.375 1550 DIRECT 1 8 120 1 LOREN COOK 90C15DH 4 7 8 EF-8 UNIT D TOILET STACK ROOF CENT. 400 0.375 1550 DIRECT 1 8 120 1 LOREN COOK 9OC15DH 4 7 8 EF-9 UNIT A TLT DRY STACK ROOF CENT. 40D 0.375 1550 DIRECT 1 8 120 1 LOREN COOK 9OC15DH 4 7 B E_F-10 UNIT D TLT DRY STACK ROOF CENT. 400 0.375 1550 DIRECT 1 8 120 1 LOREN COOK 90C15DH 4 7 8 EF-11 UNIT B TOILET STACK ROOF CENT. 200 0.375 1180 DIRECT 1 8 120 1 LOREN COOK 90C15DH 4 7 8 EF-12 UNIT C TOILET STACK ROOF CENT. 200 0.375 1180 DIRECT 1 8 120 1 LOREN COOK 90C15DH 4 7 8 EF-13 UNIT B DRYER STACK ROOF CENT. 300 0.375 1275 DIRECT 1 8 1240 LOREN COOK 90C15DH 4 7 8 EF-14 UNIT C DRYER STACK ROOF CENT. 300 0.375 1275 DIRECT 1 8 LOREN COOK 90C15DH 4 7 8 EF-15 UNIT B TOILET STACK ROOF CENT. 400 0.375 1550 DIRECT 1 8 LOREN COOK 9OC15DH 4 7 8 EF-16 UNIT C TOILET STACK ROOF CENT. 400 0.375 1550 DIRECT 1 8 LOREN COOK _ 90C15DH 4 7 8 EF-17 POOL CABANA CEILING 150 0.25 1310 DIRECT t00W LOREN COOK GC-180 1 2 EF-U1 TYPICAL UNITS CEILING 50 0.25 923 DIRECT 5OW 120 1 LOREN COOK GC-140 (1)(2) EF-L12 TYPICAL UNITS CEILING 150 0.25 1310 DIRECT 10OW 1 120 1 LO EN COOK GC-180 (1)(2) SSF-1 ATRIUM SMOKE EVAC IN -LINE PROP 15000 0,375 550 BELT 3 208 3 LOREN COOK 42XLWH 1 6 10 SSF-2 STAIRWELL SUPPLY 5000 0.375 670 BELT 2 208 3 LOREN COOK 150 ASP 1 6 9 SSF-3 STAIRWELL SUPPLY 5000 0.375 670 BELT 2 208 3 LOREN COOK _ 150 ASP i 6 9 SEF-1 ATRIUM SMOKE EVAC ROOF CENT. 40000 0.375 570 BELT 7.5 208 3 LOREN COOK SUBH-60 1 4 5 6 10 NOTES: (1) PROVIDE WITH BACKDRAFT DAMPER. (8) FAN SHALL RUN CONTI �2) SHALL OPERATE WITH LIGHT SWITCH (9) PROVIDE WITH WALL SLEEVE 3) PROVIDE WITH WALL THERMOSTAT FOR OPERATION. (10) FAN SHALL BEGIN OPE 4)PROVIDE WITH ROOF CURB. 5) PROVIDE WITH VIBRATION ISOLATOR. (6)SHALL OPERATE THRU FIRE ALARM SYSTEM WHEN SMOKE DETECTORS IN ATRIUM ARE ACTIVATED. (7) PROVIDE WITH VARIABLE SOLID STATE SPEED CONTROLLER MOUNTED AT THE UNIT. LOUSILY, AND FAN GUARD. ATION WHEN AUTOMATIC DOORS ARE PROVEN OPEN. BOILERS HEDULE DESIGNATION FUEL BURNER INPUT MBH OUTPUT MBH FLUID V/PH BASIS OF DESIGN NOTES MFG. MODEL NO. B-1 NAT. GAS 1670 1370 WA TER 120 1 TELEDYNE PH1670 1 2 NOTES: (1) UNIT SHALL BE FACTORY MADE SUITABLE FOR (2) PROVIDE ALL REQUIRED SAFTIES BY CODE AND (3) PROVIDE WITH INTEGRAL CIRCULATOR PUMP 85 A COMPLETE INSTALLATION. OUTDOOR INSTALLATION (ON ROOF) AT SEASHORE LOCATION. RECOMMENDED BY MANUFACTURER. GPM ® 15 FT HEAD, AND ALL OTHER ACCESSORIES FOR R AIR SEPARATOR DEVICE SCHEDULE DESIGNATION ASD-1 DESIGN FLOW (GPM) 725 MAX. PRESSURE DROP (FT.H2O) 5 DESIGN NOTES: BASIS ROLAITROL R-8 UNIT SHALL BE PAINTED WITH (2) COATS OF RUST INHIBITIVE PAINT AND (1) COAT OF ENAMEL PAINT. I DESIGNATION SERVICE WATER LOOP WATER LOOP EXPANSION TANK ASS'Y SCHEDULE DESIGNATION EXP-1 MIN. CAPACITY (GAL.) 250 MAX. LENGTH (IN.) 90 MAX. DIAMETER (IN.) 36 DESIGN BASIS BELL & GOSSET MODEL 240 NOTES: UNIT SHALL BE PAINT AND (1) PAINTED WITH (2) COATS COAT OF ENAMEL PAINT, OF RUST INHIBITIVE PUMP SCHEDULE GPM HEAD IMPELLER I MOTOR FT.WC DIA.IN• I H.P. I RPM I V/PH BASIS OF DESIGN MFG. MODEL NO. 'AGO 4012-7 AGO 4012-7 NOTES: (1) PUMPS SHALL BE PROVIDED WITH AUTOMATIC SEQUENCER TO OPERATE ONE OF THE TWO PUMPS AT ANY GIVEN TIME. PROVIDE INTERLOCKS TO SHUT THE ALL HEAT PUMP UNITS IN THE EVENT OF FLOW FAILURE. (2) PROVIDE WITH END SUCTION DIFFUSER. (3)ALL PUMPS SHALL BE SUITABLE FOR OUTDOOR INSTALLATION AT SEASHORE LOCATION. NOTES COOLING TOWER SCHEDULE DESIGNATION WATER MOTOR OUTDOOR AIR WET BULB 'F BASIS OF DESIGN NOTES GPM ENT 'F LVG 'F H.P. RPM V/PH MFG. MODEL NO. CT-1 725 96 86 15 1800 208 3 79 EVAPCO SST-19-79 NOTES: DIFFUSER/GRILLE/LOUVER SCHEDULE MARK / LEGEND TYPE MFG. NOTES NECK SIZE10•f-4W—THROW CEILING MOUNTED nTUS _MODEL TDC-AA (1)(2)(4)(5X6)(7) AIR QUANTITY— 3000FM SQUARE SUPPLY DIFFUSER NECK SIZE — BXB-SW SIDEWALL MOUNTED RECTANGULAR PNS 272 (1)(6) AIR QUANTITY— 2DOCFM SUPPLY AIR DIFFUSER NECK SIZE --+- 8X8­$Q CEILING OR SIDEWALL 7mS 350 (1X2)(3)(4X5)(6) AIR QUANTITY— 2DOCFM RETURN AIR GRILLE NECK SIZE --- 8X8-EC EGG CRATE STYLE TITS 50 (5) AIR QUANTITY— 200CFM SUPPLY OR RETURN GRILLE LOUVER SIZE — 24X24-OAL WALL MOUNTED RUSKIN ELF-6375D (8X9) OUTSIDE AIR INTAKE LOUVER LOUVER SIZE -► 24X24-EL WALL MOUNTED RUSKIN ELF-6375D (8X9) EXHAUST DISCHARGE LOUVER LOUVER SIZE -+- 24X24-EL2 WALL MOUNTED EXHAUST LOUVER RUSKIN ELF-63750 (80) WITH GRAVITY DAMPER NOTES: 1) PROVIDE WITH OPPOSED BLADE VOLUME DAMPER. 2 PROVIDE 2024 FULLY LOUVERED FACE LAIN MODULE MERE LOCATED IN LAYIN CEILING. 3 NECK SIZE IS 22X22 UNLESS NOTED OTHERWISE ON FLOOR PLANS. 4 PROVIDE SQUARE TO ROUND NECK TRANSITION WHERE APPLICABLE. 5 COORDINATE BORDER TYPES WITH ARCHITECTURAL FLOOR PLAN AND REFLECTED CEILING PLAN. 6 COORDINATE FINISH WITH ARCHITECT. 7 COORDINATE THROW PATTERN WITH FLOOR PLANS. 8) PROVIDE COMPLETE WITH WALL SLEEVE AND BIRDSCREEN. 9) PRIME AND PAINT TO MATCH ADJACENT SURFACES, 10) PROVIDE COMPLETE WITH INSULATED SUPPLY AIR BOOT FOR SUPPLY DUCT CONNECTION. 11) FIELD FABRICATE SUPPLY AIR PLENUM BEHIND DIFFUSER FOR SUPPLY DUCT CONNECTION. CALAAOO ° FT. PB#CE ° W. PAWBE4CH 07 CERRAPONIE = E, SUIE 1625, AETAWM SP SM FEOMOA 32701 (407) 332-5110 FAX (407) 332-7704 131 K 20 ST.. WT 20Q FT. PEACE, FL%WA 3490 (407) 466-1165 FAX (407) 4WI164 2509 FOREST IRIS BOO.. SU IE 225, REST PALM BEACH, n6R✓DA SNOB (407) 9&3-96DO FAX (407) 43h 7745 ASSOCIATES INC. , REVISIONS 0 COPYRKJff I&MI DOI XII.A.S R(X)'I' ARCIITT11f7S. AIA. RKa TfS RimckVIn. Z U5 W 0 O F- n-,,,U w Q �U Dry o Q 0 DRAWN J.L.S. C HECKH) A.K. DATE? 02/01/01 %CALF, NONE JOB NO, SHEET M601 OF SIIIl1:'I'S kolel 'A'8 Ixg Q FOR TURE TENNI COURT H2 ZOJ /10 9 H (e:\Ii TRACT "R" 1 2 3 4 5� 6 7 6 9 , 114_1�jl 16 Al 13 4 5 6 �7 8 9^I 314"C I T 112 13 1 141 15 1 16 1 17 18 t 19 11 20 ! 1 I_, � � ❑1 0 ❑1 ❑1 0 2I71 w, TO TEL. BOARD 1"C I ❑� ❑1 ❑D ❑1 E] T IM CT ET„ 1 23 24 25 26 27 e 28— 23 3r3132 1Al� 3/4"C 35 { 36 371 38 y39 40 41 42 1 Q3 0 0 � o 0 0� o o,J o ❑1 MUST BE S El: FROM BEACH. NOTE: - CONNECT SIFELIGHTING THRU CONTACTOR CONTROLLED BY TIMECLOCK - VERIFY LOC TION OF SPA & POOL EQUIPMENT H1 FOR FUTURE LIGHTING ❑1 TRACT "P" TO POOL SERNCE �— (4)#3,j!6G,1-1 /2"C POOL ) p H2 EQUIP. 25:27 FIXTURE LEGEND ® O BOLLARD - 35W HPS - 42" TO TOP, SHIELD FROM BEACH Bz 12' POLE - 175W, FACED AWAY FROM BEACH cz WALL FIXTURES - 25W INCANDESCENT (D J-BOX FOR LANDSCAPE LIGHTING NOTE: THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 626-33.007, FLORIDA ADMINISTRATIVE CODE. GEaV`T LOT 3 & 4 ELECTRICAL SITE PLAN' SCALE: 1 = 30 -0 REVISIONS V COPVRIGITP 2W DOUGH AS ROOT ARCFTITFCTS. ALL RIGHTS RRSER WO). z (� w ono 0 i- z CrU z w c� z Q �U w O Q Lw Q Q DRAWN J.H. ClIECKED TBA DATE 02/01/01 SCALE AS NOTED JOB NO. SBEET `"'MEAKNXIMM El 01 -- 07 CENIEIV IE CRCIE, SUM 1625, ALTAM M "NS, BONDA U701 (407) uz-SHO FAX (aY) M2-n" 131 R 2ND ST. SUIIE 208, FT. PIERCE, RORRA 3490 (407) 466-1165 FAX (407) 466-1164 OF SHEETS ..G I 2669 FOREST HILLS BLVD., SUITE 225. WEST PAL/ BEACH, FI IDA M406 ASSOCIATES �7.2. (407) 963-9800 FAX (407) 434-7745 INC. I r------------------------------------ 1 I I 1 1 I I I I I I I 1 I c ! c c i = 22 20 18 II 16 14 12 i 10 B 6 4 2 G1 HI G1 Ht G1 Ht O l H1 G1 I G1 Ht �: ._..Hi O' JH7 G1 H1 Ht G1 � G1 H1 H1 G1 �. -� G1 .H1. H7 G1 H1_.— H1 H1 H1 G1 G1 G1 G1 G1 - G1 G1 G1 G1 C1 21 19 17 15 13 11 9 7 5 3 C I - C C I�ICC — C C CI C ti' I ' l L----------------- -------------------------------------------- --------------------------.-------------------------- --- ---------------r ...!------------------------ / ELECTRI / I � PROVDE A CONTRACTOR IN TYPICAL GARAGE ELECTRICAL FLOOR PLAN_ PROVIDE ALL CONTROL WIRING NECESSARY FOR OPERATION OF GARAGE G1 SHOWN. GARAGE G2 SIMILAR. SCALE: 1/8"='1'-0" GARAGE DOORS. I I I§ ! SHIELD FROM BEACH 0 -w �1TJT• ET — 6 I CA) A I ■ TfY■ ■r■. _ ■ ■ Is IE4D FROM BEACH 14 H2 CABANA ELECTRICAL FLOOR PLAN SCALE: 1/4" = 1'-0' 120V (L �-N MEN'S ROOM I I I I - I WOMEN' ROOM 1 I J 120V I I I W L RESTROOM EXHAUST FAN C N ONTROL/DELAY DETAIL N.T.S. I I I I I n I I Ht I I SHIELD FROM BEACH -- +- SHIELD FROM BEACH U EH1 29 �� �- --]SHIELD FROM BEACH 0 V HI 37 EH1 Mi Y1 0 X /I Ht rn �1T1 4 SEE CONTROL/ DELAY of DETAIL TH SHEET,- 2 -------� cl HI 81 IT ,tQ^ 9I- SHIELD FROM BEACH HI NOTE: THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 62B-33.007, FLORIDA ADMINISTRATIVE CODE. ?I NEMA 3R `— PANEL "G1" PANEL "G2" 4111 I I I 1 1 I I i I / I / i 1 1 I � H1 ' I I / � I H1 0H1 •® i'. 01 f 0 / 0 � 1 (\ I 21 O1 31 EH1 ct 02 Qs o2 I EH1 L-A l_-1 _-L- I _ ct HI 3 I I 16 I' II II Q 11 MW I H1 ---- - r -- - H1 f H1 Hi 3 �dt G1 Al 0 O At SHIELD FROM BEACH `I �QM=EJ ---...... --...... _.------- -_ 1 01 i li 1 \ : I I I bl : O O I O IL _J I X 20 1 -- tA ® CONNECT TH® Q EH1 ----------r -1 EH1 , TIMECLOCK T1-27 v 1" EMPTY CONDUIT FOR SYSTEM CONDUIT - H1 I i j wi 0 02 / 02 SHIELD FROM BEACH 4 KI( C1 I I x 1 1 I EMPTY CONDUIT FOR SYSTEM CONDUIT x\ I I 1 1 I 1 I I 1 1 I CONNECT THRU TIMECLOCK T1 K1 27 H1 FIRST FLOOR LIGHTING PLAN /� SCALE: 1/8" = 1'-0" \_ ALL 2X4 FLUORESCENT FIXTURES ARE TYPE "E1" UNLESS OTHERWISE NOTED. (8) FIXTURES UNDER PORTE COCHERE ARE SEAGULL 8439-15 WITH (1) BR-40 120W LAMP. CENTER FIXTURES IN THE CENTER 0 COA&M EMOWEEM EACH RECESSED COFFER. I I j JY / I M+4l • Fr PERCE • W. P.II BE4CH 127 CDI7EAPONTE CI7) 3 SATE 1625, AL(407) E -7704 , BOROA 32701 (w� 3J2-s,18 F,X(4on 332-7704 131 N 2R0 ST., Sl 20A FT. PFRLF, RORDA 34M (407) 406-1165 FAX (407) 468-1164 2689 FOREST ILLS BLVD., SU1E 225, Ill PALM III F IM 314M ASSOCIA T£: (407) 911 FAIL (407) 434-7745 INC. 1:6a"ilHm.al Z (n W 0 O 0 z or_,U z cf) Z Q d UU W O `L W U Q DRAWN B.C.F. CI IF.(:KYJ7 TBA DATI; 02/01/01 SCALY. AS NOTED JOB NU. 's r. I E' 201 OF SIII IAS FIRE ALARM SCHEDULE SYMBOL DESCRIPTION CATALOG NUMBER F PULL STATION SIMPLEX 2099-9795 SPEAKER SIMPLEX 4902-9705 s L SPEAKER / STROBE SIMPLEX 4903-9146 (ADA) STROBE SIMPLEX 4904-9112 QH HEAT DETECTOR SIMPLEX 4098-9731/4098-9781 ©D SMOKE DETECTOR SIMPLEX 4098-9701/4098-9784 D� DUCT SMOKE DETECTOR SIMPLEX 4098-9703/4098-9701 ® RELAY SIMPLEX 2088-9007 a F FIREMAN'S PHONE SIMPLEX 2084-9001 ELEVATOR WARNING LIGHT SIMPLEX 4904-9137 04BD BEAM DETECTOR SIMPLEX 2098-9207 FS FLOW SWITCH SUPPLIED AND INSTALLED BY TS TAMPER SWITCH SPRINKLER CONTRACTOR, CONNECTED BY ELECTRICAL CONTRACTOR ® FIRE ALARM CONTROL PANEL SIMPLEX 4100-VOICE SUBSCRIPTS: WP: WEATHERPROOF E: ELEVATOR DOMESI WATER PI PROVIDE INSPECTION WELL EFEF=1 7: 30/1 LJ' 20 F=3 EFE SERVICE DISC. SW. ATS 28 FIRE PUMP CONTROLLER EM STANDBY ❑H EH1 GENERATOR H1 SF-4 ° SEE TRASH WIRING DIAI (8:10:12 EH1 -""'l0 H1 VERI WITH CON ACTOF TAMP, SWI PUMP ROOM H2 E 96'AFF 9 it v; L2-F L.t Hl' / cp 26 HP-2 ] 6 SAUNA- 1 ri 26 ❑H a _...._ 13:15 , c \ .L YAP t IRE P MP 1:3:5 /GFl .._...26 gp WSHP-1 0 26 . I MCM, #3G, 2-1/2"Crr r_- C iI a. GENERAL 110R ANNUNCIATOR PANEL' I ❑ H J' H1 28 302826 20 30 M} EF-2 ______ *,R _ FANN LING �] =.!-_.:_.+. w _ UP TO EF-6 ON ROOF �----- .- —_—�_: �- 8 _ � 1 f �ul_J a "H" w i z 9:11:13 H1 S ER CENTER pi ' 1 EM 11 � FI FPHONFh T77 3/4"C 17:19 H1 26 H1 16 H1 H2 I 02 H2 IRRIG. TIMER ❑1 I i I \ WP/GFl i WP/GFl F'___OUNTA__ 1 I I PUMP J—BOX FOR FA ELEVATOR WARNING LIGHT f i I ; TO TEL. H2 , 1 1 I 0 J—BOX FOR FA LIGHT� FIRST FLOOR POWER AND SYSTEMS PLAN SCALE: 1/8" FOR FUTURE RANGE-1 H1 Hl 14 14 1"C RISER FOR SATELLITE FEED PROVIDE BOX EACH FLOOR 14 ENTRANCE DOOR CONTROL 'H1 18 20 \'+ 22 1214 H1 12 NOTE: THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 626-33.007, FLORIDA ADMINISTRATIVE CODE. PRQMDE INSPECTIONWELL 1 i9 1i I 2 � t i I i I ' 14 12 12 EMPTY CONDUIT UP TO ROOF (TYPICAL FOR 5) NOTE: VERIFY ALL ELECTRICAL REQUIREMENTS FOR KITCHEN, HVAC, WH, SAUNA, PUMP & SF, EF EQUIPMENT. KEYNOTES Fil: ❑1 PROVIDE COVER LISTED AS WEATHERPROOF WITH RECEPTACLE ATTACHED CONRUM BVI13NEEM O LAAD0 • FT. P6#w ° W. PALA/smw 42T CEN1EIM IT ORCTE, SUITE I= ALUNONTE SPRM % R MA 32701 (407) 332-5110 FAX (407) 332-7704 131 N. 2ND ST., SITE 206 FT. ROM FL0RIDA 3" (407) 465-1165 FAX (407) 465-1154 2559 FOREST HU.S BLVO., SITE 225, WEST PALM BEACH, FLOROA 3N05 ASSOCIATES (407) 963-MM FAX (407) 434-7745 INC. REVISIONS €9 COPYRUGUr 20D0 DOUGLAS ROOT ARCHITECTS. AL.I, RK;Krs RESERVED. Z V) 0 z ryU z Z Q Q d UU LIJ cr- ry 0Qw 0 ~ U Q t� O DRAWN B.C.F. CIIrCKFD TBA DATE 02/01/01 SCALE AS NOTED JOB NO. SIIEET E202 OF SIIEml r I - I I I I I I , 1 I 4 1" EMPTY CONDUIT O I 1" EMPTY CONDUIT i / \ t ` A/11 'GFCI RE Q \ 1 I I GFIRUIIR 1 I I , T PANEL ;THOUSEWPM T fH2 IH3.I' 175 H3 1 ' TO SWITCH IN El�2 F�EDE P-TWR-2 P-COND-2 _ 1 O H3 ns H3 - 0 SWITCH IN PENTHOUSE " - — - /3 N2/D Dt ENTHOUSE _ 1 244Li H3 1 1'c 1-1/2'c /" PANEL PENTHOUSE)-- .____Wm.�,_._..:- - P - ( r3 r 1"C �.....- 18 H3 i 26:28:30 38:40:42 / .... PANEL PENTH SE /3 _ i4 125 44 — - - - H H3 i 1 , P X .1 .., 0 t^,t 100 - -5 100 20 \AIITIGl S FOR \ AC-6 ( — - \�\ 1 \ D I /-T H3 5�' T EXHAUST 3� +._ t'1 _ 1_.r { 3 MPTY CONDUIT �' J-BOIL F fAT WP/GFl f D1 WP/GFI /� �. a" \,� H3 i1 r WP/GFI B1 ' Di- ELECTRICAL CONTRACTOR TO PROVIDE WP ENCLOSURE ? '1 C1 A YL .P 1 mu (TYPICAL) At "Y \ - Al t F- EH2 i \ Al �V r '\ �,<.- Will _ 25: 27: F 'c1 ' � \ %' EH2 31:33:,S5(- / y- J BOX FOR FA 12 V T IP - '' -. _ lr HEAT 6rTEZY06 M 11 20V T / M 120V FOR SHUNT�TPoP EH2 _ l• �}--- ` 30 `• IirM TO TAvD I _ !I / \ Fl�FI. M \ 20 20: 22:2 11 r - X sE�_1 p10 F - y 6 $$ 30 _..-- EH2 H2 I' EMPTY CONDIT \. RELAY FOR SPEAKER IN CAB EH2 SPEAKER IN CAB ~ PRESSURIZATION FAN AND PHONE JACK AND PHONE JACK RELAY FOR SMOKE DETECTOR AT PRESSURIZATION FAN TOP OF SHAFT (TYPICAL) • REQUIRED TO PEN WF/GF n F-9 I EFEF=11 WP TO SWITCH IN PENTHOUS 10' MAST W/ AVIATION EIGHT- EE1� � rc_Pa TO PE' ' Wo 0 m WP/GFl 9) TO SWITCH IN 011 PENTHOUSE ,, .PANELPANEL PENTI fRTT - drll-trM j� H- _ I �`_` Et " M EE_14 j ��. -- 20:22:1/2/4 /3 1441 2= 34.36 CTRICAL ROOF PLAN SCALE: 1/8" = 1'-0" _ NOTE; ELECTRICAL CONTRACTOR TO VERIFY ALL ELECTRICAL REQUIREMENTS FOR ALLL EQUIPMENT ON THE ROOF. 1" EMPTY CONDUIT i I I I I I i I I 1" EMPTY CONDUIT REVISIONS NOTE: THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE .WITH THE STANDARDS ESTABLISHED IN SECTION 6213-33.007, FLORIDA ADMINISTRATIVE CODE. ' Q(OPVR RiI ff 201D Will ROW ARCI minis. AIL. RR IFISRFSRRVIO). vVlra7(/L" / M ENCOYEIGM CALAAUO " ".PERM • W. P" 6EACH 427 GENTERIl 7E GYBE. SUITE IM ALTAll SPRINGS, FLORIDA 32701 (401) 332-5110 FAIL (407) 331 131 R 27U ST., SL47E 200. FT. FIERCE. FLORIDA Mw (401) 455-1155 FAIL (407) 466-1154 2509 FOREST IILS BLID.. SUITE 225, REST PALM BEACH. FLORIDA 33400 ASSOCJAT£S (407) 903-9BD0 FAX (407) 434- 7745 INC. z Cn L1J 0 0f - z rU z W z _j LLj OQ w 0 ~ U Q d DRAWN B.C.F. (11F.('ICED TBA Mill:, 02/01/01 SCA 1.F.. AS NOTED JM NO E203 OF 11 ..F.T SIIkI IN