HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONS.0 A . �.��� J ENGINEERING & TESTING INC. Phone: (866) 781-6889 •Fax: (866) 784-8.550 www.fioiidaengineeringandtesting.com APR 0� 6 2018 250 S.W.13"' Avenue Pompano Beach, FL 33069 ST. Lucie County, Permitting DATE: 4/03/18 JOB ORDER #: 18-1393 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 I Fort Pierce, Florida 34982 PROJECT: Black Residence I Gulf Coast 5V Crimp Roof Panels ADDRESS: 5510 San DieLyo Avenue Fort Pierce, Florida 34946 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height = Max. 15' Exposure: G Basic/Ultimate Wind Speed: V,,tt=170 mph Length = 72' Category: II Nominal Wind Speed: V.d=Vuit*40.6 Width = 43' Slope: 4/12 =18' (asd = allowable strength design) Parapet Wall: N/A Residence KZ = 0.85, Kzt = 1.0, Kd = 0.85 i I I Design Calculations: I F-ILE COPV Velocity Pressure: q = 0.00256*KZKAdV2 Velocity Pressure („ lt): q=0.00256(0.85+�(1.0)(0.85)(170)Z] = 53.45 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*�0.6)2] = 32.07 psf Width of Pressure Coefficient: 0.1(43') 0.4(15') Effective Wind Area: <10f 2 I External Pressure Coefficient: 1) GCP1 = -0.9 2 GCP2 — 1 7 = 4.3' = 6.0' } use: 4'6" Internal Pressure Coefficient: 1) GCP; = 0.18 3) GCP3 = -2.6 I i Design Pressures Based on Vasd: I 1) Field PI = 32.07*[(-0.9) — (0.18)] = -34.6 psf 2) Perimeter P2 = 32.07*[(-1.7) — (0.18)] = -60.3 psf 3) Corners P3 = 32.07* [(-2.6) — (0.18)] = -89.2 psf a Qri Ility'�44 \�A 119.4s irdnce V. Page 2, 4/03/18, Job Order All Area Roofing Black Residence- Modular Home Gulf Coast 5V Crimp Roof Panels 5510 San Diego Avenue; Fort Pierce, FL: Attachment Requirements: FILOIUnA Based on the requirements of Florida Product Approval # 11651.12 R3 with maximum design pressures of-108.5psf; the following are our recommended fastening patterns to attach the 26 ga. steel Gulf Coast 5V Crimp roof panels (24" coverage) to the minimum 15/32" plywood decking with # 9-15 x 1.5" astener with sealing washing through panel ribs with 1/4" minimum penetration through e plywood as follows: Area Field, Perimeter & Corner Maximum Total Uplift Design Pressure -108.5 sf Fastener Pattern Panel Rib Fastener Row Spacing 12" o.c. Fastener Spacing (Along Rows) Type 1-12" o.c Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 4'6" (Zone 2: Perimeter (including along ridges) is a 4'6" wide strip, Zone 3: Corners are 4'6" x 4'6") Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance notice of acceptance and manu Code 2017 Edition. the local building code product control er specifications and Florida Building Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected representative) or a building dep specifications. by our field engineer (or authorized tment inspector to verify compliance with Sincerely, Mark A. Mesiano, IH Florida Engineering Florida Reg. No. 4821, Certificate of Authori